background image

To operate the fire in any of the above modes, the front switch marked ((OI) must be switched to the “on” posi-
tion. 

To operate the fire, the first switch must be turned on firstly, followed by the second switch to start the blower,
if required. To obtain heat from the appliance, the I switch must then be operated for LOW heat, followed by
the II switch for the HIGH heat setting. 

The aappliance ccan bbe sswitched ooff aat aany ttime, iirrespective oof  tthe pparticular m

mode sselected, bby ssimply sswitch-

ing tthe ffirst sswitch m

marked ((OI) tto tthe ““off” pposition. 

It iis aalso rrecommended tto uunplug tthe ppower ssupply ccable aat tthe ssupply ooutlet w

when nnot iin uuse.  

SAFETY C

CUT-O

OUT SSYSTEM

This appliance has a safety cut-out system fitted which will activate if the air inlets or heater outlets are obstruct-
ed. For safety reasons the fire WILL N

NOT switch on again automatically. 

NOTE: TThe vvisual llight eeffect w

will rremain ooperational iif tthe ccut-oout iis aactivated, oonly tthe ffan hheater eelements aare

prevented ffrom ooperating. 

The ffollowing pprocedure m

must bbe ccarried oout bbefore tthe ffire ccan bbe ooperated aagain:

1. Unplug the power supply cable at tthe ooutlet ssocket aand pplace aall sswitches tto ooff aat tthe aappliance. 

2. Leave the fire OFF for a period of not less than 10 minutes, ensuring any obstructions are removed. 

3. Plug in the power supply cable at tthe ooutlet ssocket, aand tthen sswitch oon aat tthe aappliance.

If the appliance fails to operate correctly, repeat the above procedure.

If an attempt to switch on is made before the safety cut-out has reset, the heaters may cut-out for a further peri-
od of time. If the sequence has been followed correctly and the heaters still fail to function, check the power
supply cable plug is plugged in at the outlet socket.  If this is not the cause, call an electrician.

MAINTENANCE aand LLAMP REPLACEMANT

ALWAYS  D

DISCONNECT/ISOLATE  TTHE  A

APPLIANCE  A

AT  TTHE  SSUPPLY/OUTLET  SSOCKET  A

AND ALLOW  TTO

COOL BBEFORE U

UNDERTAKING A

ANY M

MAINTENANCE.

Excluding the lamp and fuse, use only genuine spare parts available from your supplier. Replacement lamps must
be of the same wattage and specification as those stated in Section 2.0 Appliance Data/Specifications.

Replacing tthe LLight BBulb. 

1. Switch off at the appliance, and then disconnect the plug
from the outlet socket.

2. Fully open the door and remove the lower lamp cover plate
(2 x screws), as described in section 8.0 to gain access to the
bulb. Note: the fuel bed can be removed if necessary to aid
replacement.

3. The bulb has a conventional bayonet fitting. Remove and
replace with the new bulb (see Fig 8 opposite).

4. Reposition the lower lamp cover plate and replace the two No 8 POZI screws, and tighten fully.  

5. Re-connect electrical supply and check for correct operation of the lamp and spinner assembly. 

77

11.0

12.0

Fig 88

©

2007 Focal Point Fires plc.

Содержание OBLIQUE ELECTRIC

Страница 1: ...these i instructions c completely b before c commencing a any a assembly o or i installation Check t that a all c components a are i included i in t the p pack Revision C 09 07 Focal Point Fires plc...

Страница 2: ...per son APPLIANCE D DATA ELECTRICAL INSTALLATION REQUIREMENTS The appliance is supplied with a pre wired 3 pin BS1363 plug 13 Amp fuse rated and 2 metre cable A stan dard switched outlet wall socket i...

Страница 3: ...any electrical equipment e g plasma screen TV sets etc on the wall above the appliance site in a position where curtains or drapes could cover the appliance site in a position where other soft materi...

Страница 4: ...st below Please dispose of all packaging with care at your local recycling centre COMPONENT C CHECKLIST QUANTITY DESCRIPTION 1 Fire Appliance fitted with Decorative Frame and Corner Wall Bracket 1 Bag...

Страница 5: ...be used Depending on the condition of the wall it may be necessary to use additional fixings In this situation any additional fix ings and wall plugs should be of the same size and type as the ones p...

Страница 6: ...xing hole aligns with the wall plug and then insert 1 x 37mm long fixing screw and fully tighten Finally fully tighten the two upper fixing screws through the two panel acess holes at the front of the...

Страница 7: ...Before U Use Check that the heater outlet grille mounted at the top of the appliance is not covered or obstructed in any way and ensure the power to the fire is switched on The appliance is controlled...

Страница 8: ...minutes ensuring any obstructions are removed 3 Plug in the power supply cable at t the o outlet s socket a and t then s switch o on a at t the a appliance If the appliance fails to operate correctly...

Страница 9: ...e cover and then refit both into plug If the fuse cover A is missing or lost the plug must not be used until a replacement is fitted Replacements are available from your local electrical store 8 As ou...

Страница 10: ...Appliance Views and Dimensions All dimensions in mm Corner W W all M M ounting B B racket 9 2007 Focal Point Fires plc 416 5 CTRS 304 CTRS...

Отзывы: