The Oblique electric wall heater provides convected heating in conjunction with a visual fuel effect display. 

The appliance is designed for indoor use, and can be flat wall mounted in the majority of wall positions antici-

pated. However as an alternative, it can be wall mounted in a corner location using the corner  mounting brack-

et. The appliance can be be located in any household room, with the exception of bathrooms. Read all of the

instructions before commencing installation. Retain for future reference and pass on as necessary to subsequent

owners of the appliance.

DO NOT use this appliance immediately below a fixed socket outlet.

DO NOT use this appliance in the immediate vicinity of a bath, shower, swimming pool or other area where

water/moisture could present a hazard.

CAUTION:  TThis aappliance m

must nnot bbe uused iin cconjunction w

with aany ttimer, pprogrammer oor tthermal ccontrol, oor

any oother ddevice tthat w

will sswitch oon tthe aappliance aautomatically, aas aa ffire rrisk m

may ooccur iif tthe hheaters aare aacci-

dentally ccovered oor ddisplaced. N

Note: TThe hheater ooutlet iis llocated oon tthe ttop ssurface bbehind tthe ffront fframe. 

Do not allow the heater to be covered as this may cause overheating. Additionally, DO NOT place any items on

top of this appliance. The appliance must not be placed near curtains or similar material. A clearance space of

at least 500mm should be allowed in front of the appliance. 

The eelectrical ssocket tthat tthe aappliance uuses M

MUST bbe eeasily aaccessible. D

Do nnot rroute tthe ssupply ccord ddirectly

over oor aabove tthe hheater uunit. IIf tthe ccord iis ddamaged, iit m

must bbe rreplaced bby aa sservice aagent oor ccompetent pper-

son.

APPLIANCE D

DATA

ELECTRICAL INSTALLATION REQUIREMENTS

The appliance is supplied with a pre-wired 3-pin BS1363 plug (13 Amp fuse rated), and 2 metre cable. A stan-

dard switched outlet/wall socket, (including earth provision), must therefore be located within this distance, and

be easily accessible in order to isolate the supply for maintenance and cleaning. This socket 

must not be mount-

ed behind or above the appliance. Note: the pre-wired 3-pin plug should not be removed, as this may invalidate

warrenty.     

It is recommended that the installation should be protected by a 30mA RCD, (Residual Circuit Device),
either via the existing main consumer unit if fitted, or by a dedicated device as part of this installation. 

1

Section Contents      

PPage N

No

1.0

Preliminary Notes 

1

2.0

Appliance Data/Specifications

1

3.0

Electrical Installation Requirements

1

4.0

Site Requirements

2

5.0

Clearances to Combustible Materials

2

6.0

Unpacking the Appliance

3

7.0

Component Checklist

3

1.0

Section Contents      

PPage N

No

8.0

Preparing the Appliance

3

9.0

Fixing the Appliance

4

10.0

Operating the Appliance

6

11.0

Safety Cut-Out System

12.0  Maintenance - Lamp Replacement

7

13.0

Cleaning

8

14.0

Servicing

8  

Weight ((kg):

11.2 kg (13.3kg including corner mounting bracket)

Dimensions ((mm):

H 675 x W 546 x D 171(excluding corner mounting bracket) 

Voltage ((Volts):

230-240V a.c. 50Hz

Heating EElements:

2 x 900/1000 Watts

Supply C

Cord:

2 metres

Supply PPlug:

BS1363, (13A BS1362 Fused)

Location:

Indoor Use Flat or Corner Wall - Non Bathroom/Shower Rooms

Lighting:

1 x 60W Amber “bayonet connection” lamp

2.0

3.0

This aappliance cconforms tto EEuropean D

Directive: 

73/23/EEC LLow V

Voltage ((Safety), aand C

CE M

Marking D

Directive.

IMPORTANT

THIS A

APPLIANCE MUST BE EARTHED

The m

manufacturer ddeclines aall lliabilities ffor iinjury tto ppersons, oor ddamage tto pproperty, rresulting ffrom ffailure tto

observe tthis rregulation, aand/or ffailure tto ffollow oor oobserve tthese iinstructions. 

©

2007 Focal Point Fires plc.

Содержание OBLIQUE ELECTRIC

Страница 1: ...these i instructions c completely b before c commencing a any a assembly o or i installation Check t that a all c components a are i included i in t the p pack Revision C 09 07 Focal Point Fires plc...

Страница 2: ...per son APPLIANCE D DATA ELECTRICAL INSTALLATION REQUIREMENTS The appliance is supplied with a pre wired 3 pin BS1363 plug 13 Amp fuse rated and 2 metre cable A stan dard switched outlet wall socket i...

Страница 3: ...any electrical equipment e g plasma screen TV sets etc on the wall above the appliance site in a position where curtains or drapes could cover the appliance site in a position where other soft materi...

Страница 4: ...st below Please dispose of all packaging with care at your local recycling centre COMPONENT C CHECKLIST QUANTITY DESCRIPTION 1 Fire Appliance fitted with Decorative Frame and Corner Wall Bracket 1 Bag...

Страница 5: ...be used Depending on the condition of the wall it may be necessary to use additional fixings In this situation any additional fix ings and wall plugs should be of the same size and type as the ones p...

Страница 6: ...xing hole aligns with the wall plug and then insert 1 x 37mm long fixing screw and fully tighten Finally fully tighten the two upper fixing screws through the two panel acess holes at the front of the...

Страница 7: ...Before U Use Check that the heater outlet grille mounted at the top of the appliance is not covered or obstructed in any way and ensure the power to the fire is switched on The appliance is controlled...

Страница 8: ...minutes ensuring any obstructions are removed 3 Plug in the power supply cable at t the o outlet s socket a and t then s switch o on a at t the a appliance If the appliance fails to operate correctly...

Страница 9: ...e cover and then refit both into plug If the fuse cover A is missing or lost the plug must not be used until a replacement is fitted Replacements are available from your local electrical store 8 As ou...

Страница 10: ...Appliance Views and Dimensions All dimensions in mm Corner W W all M M ounting B B racket 9 2007 Focal Point Fires plc 416 5 CTRS 304 CTRS...

Отзывы: