DO NOT
-
mount on a wall.
-
recess any part of the appliance into the wall.
-
site in a position where curtains or drapes could cover the appliance.
-
site in a position where other soft materials could cover e.g. below a coat rack.
-
site behind an opening door where mechanical impact/damage could occur.
-
site where the supply cable would become a trip hazard.
-
sit, stand or forcefully pull on the appliance.
-
obstruct, cover or force items into the openings.
-
use the heater to dry clothes.
-
site/use in an outdoor location(s).
-
run the supply cable under carpets
.
It is important that the following clearances are maintained from the appliance to combustible materials and are dependant on the desired
mounting location as defined below.
This appliance is designed to be floor mounted only.
The minimum distance from the top of the appliance to a ceiling is 500mm.
The minimum distance to the sides of the appliance is 100mm.
The minimum distance to the front of the applaince is 500mm.
A shelf of any size or design may me mounted above the appliance.
Caution: This appliance is heavy. Always seek assistance whilst unpacking and/or during installation.
Read
all
the instructions before continuing to unpack or install this appliance. Carefully remove the appliance from its packaging and lay on the
floor with it`s back surface downward. Check that the remaining packaging contents correlate with the component checklist below. Please dis-
pose of all packaging with care at your local recycling centre.
QUANTITY
DESCRIPTION
1
Fire suite
1
Remote control handset
1
Mains supply cord
1
Instruction Booklet
Read All Instructions Before Use
Check that the heater outlet grille, mounted at the top of the appliance, is not covered or obstructed in anyway, and ensure the power to the
fire is switched on. The power to the LCD display panel and the heater functions are controlled using four switches mounted underneath the
opening at the right hand side.
Controlling the heater functions
The first switch towards the top,
marked (0I)
, controls the main power to the appliance and switches on the LCD display panel. This feature
can be used independently of the heating features.
The next switch down,
marked (
*
)
operates the fan blower without heat, and can be used for cool air circulation. However for this feature,
the main power switch (0I), must also be in the “on” position.
The next switch down, with a “single bar”
marked (I)
operates the low heat, (1kW), setting.
The switch at the bottom, with “two single bars”
marked (II),
operates the high heat, (2kW) setting.
To operate the fire in any of the above modes, the top switch
marked (OI)
must be switched to the “on” position.
To operate the fire, the
(OI)
switch must be on, followed by the
(
*
)
switch to start the blower. To obtain heat from the appliance, the
blower must be on and the I switch must then be operated for LOW heat, followed by the II switch for the HIGH heat setting.