3
©
202
1
Focal Point Fires Ltd.
2.0 INSTALLATION REQUIREMENTS
3.0 APPLIANCE DATA
Supply Voltage and rating power : 220-240V AC
~
50Hz, 1
800
W
Heating Elements :
2 x 900W
Location :
Indoor use only
Fuse Rating :
1
3
Amp
Lighting :
LED's
Supply plug/cord :
BS1363/1.6 metres length
The appliance is supplied with a pre-wired three pin BS1363 plug (1
3
Amp fuse rated) and 1.6
meters
of electrical flex. It is therefore
necessary for a suitable electrical socket to be located within this distance of the appliance and be easily accessible. The stove may be
installed on a combustible or non-combustible floor, however the heater outlet is underneath the stove and certain types of floor cov-
ering may be affected by the heat produced by the stove. The ability of the floor covering to withstand the heat produced by the stove
should be ascertained before proceeding with the installation of the stove. If in doubt then the stove should be mounted on a non-com-
bustible hearth or plinth which extends for at least 150mm in front of the stove.
This appliance should be positioned on a firm level
sur-face. If the stove is to be sited in a fire surround then the suitability of the surround for use with electrical heaters should be estab-
lished with the fire surround manufacturer.
If fitted into an open draught fireplace, it is advisable to block off the chimney to reduce the
risk of draught through the stove which may cause the safety cut out system in the fan heater to operate. If you are placing the heater
in an alcove, make sure that there is at least 150mm of space on all sides to ensure good air circulation.
•
DO NOT
run the mains cable under carpets, rugs etc.
•
DO NOT
cover or obstruct the heater in any way. Overheating will result if it is acci-
dentally covered.
• Never immerse the product in water or any other liquids.
•
DO NOT
use the appliance outdoors.
• Before cleaning the appliance, ensure it is unplugged from the power and that it is com-
pletely cool.
•
DO NOT
clean the appliance with abrasive chemicals.
• Never use accessories that are not recommended or supplied by the manufacturer. It
could cause danger to the user or damage to the appliance.
•
DO NOT
insert or allow foreign objects to enter the inlet or outlet vents as this may
result in electric shock, fire or damage to the appliance.
•
DO NOT
install the fire using an extension cord.
• Unplug from the mains supply if the appliance is not to be used for long periods.
• This product is only suitable for well insulated spaces or occasional use.
1.0 IMPORTANT NOTES - CONTINUED
GB IE
Model
ND-
1
8
1
MLR
Item
Symbol
Value
Unit
Item
Unit
Heat output
Types of heat input, for electric storage local
space heaters only
Nominal
heat output
P
nom
1.8
KW
Manual heat charge control with
integrated thermostat
N/A
Minimum heat
output
(indicative)
P
min
0.9
KW
Manual heat charge control with
room and/or outdoor temperature
feedback
N/A
Maximum
continuous heat
output
P
max, c
1.8
KW
Electronic heat charge control with
room and/or outdoor temperature
feedback
N/A
Auxiliary electricity consumption
Fan assisted heat output
N/A
At nominal
heat output
el
max
0.0
13 (fan motor)
KW
Type of heat output/room temperature control
At minimum
heat output
el
min
KW
Single stage heat output and no
room temperature control
No
In standby mode
el
SB
0.
35
W
Two or more manual stages no tem-
perature control
No
With mechanical thermostat room
temperature control
Yes
With electronic room temperature
control
No
Electronic room temperature con-
trol plus day timer
No
Electronic room temperature con-
trol plus week timer
No
0.0
13 (fan motor)