background image

3

© 

202

1

 Focal Point Fires Ltd.

2.0 INSTALLATION REQUIREMENTS

3.0 APPLIANCE DATA

Supply Voltage and rating power : 220-240V AC 

~

50Hz, 1

800

W

 

Heating Elements :

 

2 x 900W

Location :

 

Indoor use only

Fuse Rating :

 

1

3

Amp

Lighting :

 

LED's

Supply plug/cord :

 

BS1363/1.6 metres length

The appliance is supplied with a pre-wired three pin BS1363 plug (1

3

Amp fuse rated) and 1.6 

meters

 of electrical flex. It is therefore

 

necessary for a suitable electrical socket to be located within this distance of the appliance and be easily accessible. The stove may be

 

installed on a combustible or non-combustible floor, however the heater outlet is underneath the stove and certain types of floor cov-

ering may be affected by the heat produced by the stove. The ability of the floor covering to withstand the heat produced by the stove

 

should be ascertained before proceeding with the installation of the stove. If in doubt then the stove should be mounted on a non-com-

bustible hearth or plinth which extends for at least 150mm in front of the stove.

 

This appliance should be positioned on a firm level 

sur-face.  If the stove is to be sited in a fire surround then the suitability of the surround for use with electrical heaters should be estab-

lished with the fire surround manufacturer.

 

If fitted into an open draught fireplace, it is advisable to block off the chimney to reduce the

 

risk of draught through the stove which may cause the safety cut out system in the fan heater to operate. If you are placing the heater

 

in an alcove, make sure that there is at least 150mm of space on all sides to ensure good air circulation.

DO NOT

run the mains cable under carpets, rugs etc.

DO NOT

cover or obstruct the heater in any way. Overheating will result if it is acci-

dentally covered.

• Never immerse the product in water or any other liquids.

DO NOT

use the appliance outdoors.

• Before cleaning the appliance, ensure it is unplugged from the power and that it is com-

pletely cool.

DO NOT

clean the appliance with abrasive chemicals.

• Never use accessories that are not recommended or supplied by the manufacturer. It

could cause danger to the user or damage to the appliance.

DO NOT

insert or allow foreign objects to enter the inlet or outlet vents as this may

result in electric shock, fire or damage to the appliance.

DO NOT

install the fire using an extension cord.

• Unplug from the mains supply if the appliance is not to be used for long periods.

• This product is only suitable for well insulated spaces or occasional use.

1.0 IMPORTANT NOTES - CONTINUED

GB IE

Model

ND-

1

8

1

MLR

Item

Symbol

Value

Unit

Item

Unit

Heat output

Types of heat input, for electric storage local

space heaters only 

Nominal

heat output

P

nom

1.8

KW

Manual heat charge control with

integrated thermostat

N/A

Minimum heat

output
(indicative)

P

min

0.9

KW

Manual heat charge control with

room and/or outdoor temperature
feedback

N/A

Maximum
continuous heat
output

P

max, c

1.8

KW

Electronic heat charge control with
room and/or outdoor temperature
feedback

N/A

Auxiliary electricity consumption

Fan assisted heat output

N/A

At nominal

heat output

el

max

0.0

13 (fan motor)

KW

Type of heat output/room temperature control

At minimum
heat output

el

min

KW

Single stage heat output and no
room temperature control

No

In standby mode

el

SB

0.

35

W

Two or more manual stages no tem-
perature control

No

With mechanical thermostat room
temperature control

Yes

With electronic room temperature
control

No

Electronic room temperature con-
trol plus day timer

No

Electronic room temperature con-
trol plus week timer

No

0.0

13 (fan motor)

Содержание ND-181MLR

Страница 1: ...t per mitted to copy or adapt any of the content without the prior written permission of Focal Point Fires Ltd 1 All instructions must be handed to the user for safekeeping Revision B 03 21 2021 Focal...

Страница 2: ...ot and cause burns Particular attention has to be given where children and vulnerable people are present If the supply cord is damaged it must be replaced by the manufacturer its service agent or simi...

Страница 3: ...he heater in any way Overheating will result if it is acci dentally covered Never immerse the product in water or any other liquids DO NOT use the appliance outdoors Before cleaning the appliance ensu...

Страница 4: ...ions Room temperature control with presence detection No Room temperature control with open window detection No With distance control option No With adaptive start control No With working time limitat...

Страница 5: ...or light will appear to indicate that the function is ON Press the O I button for 3 seconds this will operate the dimmer mode to adjust the desired flame brightness setting Press the 900W button 4 onc...

Страница 6: ...pond with the colour markings identifying the terminals in your plug proceed as follows The blue wire must be connected to the terminal marked with an N or coloured black The brown wire must be connec...

Страница 7: ...f the original guarantee period and the guarantee period will not be extended even if we repair or replace any product or part If we replace any component or product the component or product removed w...

Отзывы: