background image

10.0 OPERATING THE FIRE 

R E A D  A L L   I N S T RU C T I O N S   B E F O R E   U S E !

Check that the fan outlet, mounted underneath the opening at the top, is not covered or obstructed in any way, and ensure the power
to the fire is switched on. The appliance is controlled using four switches mounted underneath the opening at the right hand side. 

To operate the fire in any of the above modes, the left hand switch marked (OI) must be switched to the “on” position. To oper-
ate the fire, the left switch must be turned on first, followed by the second switch to start the blower, if required. To obtain heat
from the appliance, the I switch must then be operated for LOW heat, followed by the II switch for the HIGH heat setting. 
The appliance can be switched off at any time, irrespective of  the particular mode selected, by simply switching the left hand
switch marked (OI) to the “off” position. It is also recommended to unplug the power supply cable at the supply outlet when not
in use.  

This appliance has a safety cut-out system fitted which will activate if the air inlets or outlets are obstructed. For safety reasons
the fire WILL NOT switch on again automatically.  NOTE: The visual light effect will remain operational if the cut-out is activated,
only the fan heater is prevented from operating. 

The following procedure must be carried out before the fire can be operated again:
Unplug the power supply cable at the outlet socket and place all switches to off at the appliance. Leave the fire OFF for a period
of not less than 10 minutes, ensuring any obstructions are removed. Plug in the power supply cable at the outlet socket, and then
switch on at the appliance. 

If the appliance fails to operate correctly, repeat the above procedure. If an attempt to switch on is made before the safety cut-
out has reset, the heaters may cut-out for a further period of time. If the sequence has been followed correctly and the heaters
still fail to function, check the power supply cable plug is plugged in to the outlet socket.  If this is not the cause, call an electri-
cian.

ALWAYS DISCONNECT THE APPLIANCE FROM THE MAINS SUPPLY OUTLET SOCKET BEFORE

UNDERTAKING ANY  MAINTENANCE!

Excluding lamps and fuses, use only genuine spare parts available from your supplier. Replacement lamps must be of the same
wattage and specification as those stated in Section 3.0 Appliance Data.

Replacing the light bulbs. 
1. Switch off at the appliance, and then disconnect the appliance at the outlet socket.
2. Remove the decorative facia from the appliance (see section 7.0).
3. Remove the six screws as shown in figure 4 and remove the lower panel.
4. Remove the light bulb(s). Note that the bulbs have a conventional bayonet fitting. Replace with a new bulb(s). Refer to section 14.0.
5. Replace the lower panel and replace the six screws shown in figure 4. 
6. Replace the decorative facia.
7. Reconnect electrical supply and check for correct operation of lamps and both spinner assemblies. 

ALWAYS DISCONNECT THE APPLIANCE FROM THE MAINS SUPPLY OUTLET SOCKET BEFORE

UNDERTAKING ANY  MAINTENANCE!

There are no specific requirements for care, other than regular cleaning of the general appliance. A wipe with a dry cloth is nor-
mally sufficient. DO NOT use abrasive cleaners as they can damage the finish. Stainless steel parts (where applicable) may be
cleaned using an appropriate metal cleaner or baby oil. Test on a hidden part of the stainless steel before cleaning. Clean only in
the direction of the grain. Mirror and glass surfaces may be cleaned using normal glass cleaner. 

Refer to Section 3.0 Appliance Data for lamp and fuse specification. Excluding lamps and fuses, use only genuine manufacturers
spare parts available from your supplier. We recommend ‘GE Fireglow’ replacement lamps. Do not use ‘Maxim’ branded lamps as
these have been found to cause discolouration of the white inner firebox.

GB IE

As our policy is one of continuous improvement and development, we therefore hope that you will understand we must retain the right to amend details and/or specifica-
tions without prior notice.

4

©

2010 Focal Point Fires plc.

13.0 CLEANING

11.0 SAFETY CUT-OUT SYSTEM

12.0 MAINTENANCE

14.0 SPARES

Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice.

F860990

• 

The left hand switch marked (0I), controls the main power to the appliance and switches on the visual light display. This fea-

ture can be used independently of the heating features. 

• 

The next switch marked (*) operates the fan blower without heat, and can be used for cool air circulation. However for this

feature, the main power switch (0I), must also be in the “on” position.

• 

The next switch with a “single bar” marked (I) operates the low heat, (1kW), setting. 

• 

The switch with “ two single bars” marked (II) operates the high heat, (2kW), setting.

Отзывы: