• The installation and Servicing of this fire MUST only be carried out by a competent person in accordance with local Codes
and/or Regulations, Building Regulations and the manufacturer's instructions. Failure to comply with these could lead to pros-
ecution and invalidate the appliance warranty. In the event of gas leakage from the appliance, the gas supply must be turned off
at the nearest isolating valve. This appliance is only suitable for the gas type for which it is supplied.
• Keep a note of the installer's name and address, GAS SAFE registration number and the original purchase receipt and the date
of installation. Failure to produce this information may invalidate the warranty. The appliance should be serviced regularly to
ensure continued safe operation. See the servicing section for further reference.
• Parts of this appliance become naturally hot during use. It is recommended that a suitable fireguard is used, especially where
young children, pets, the elderly or infirm are concerned. The manufacturer of this appliance considers all surfaces as working
surfaces with the exception of the control knob and ash pan door.
• As with any gas fire, a fire guard complying with BS 8423 must be used in presence of pets, children, and the
elderly or infirm.
• The appliance should be serviced regularly to ensure continued safe operation. Frequency of service will depend on use, but
MUST be carried out at least once annually.
• Combustible items, such as flooring and furniture and soft wall coverings (such as blown vinyl or embossed paper), low tem-
perature surrounds etc may discolour if fitted too close to the fire. See relevant section for further details on clearances to
combustibles. No combustible materials or flooring should protrude onto the hearth.
• This appliance incorporates a combustion monitoring system (ODS).
• DO NOT burn any foreign material on this fire, the coals must be of the correct type and laid out in accordance with the rel-
evant section of these instructions. Failure to do so could create a hazard or lead to sooting.
• The fire is only suitable for use with the gas type for which it is supplied.
• This appliance is fitted with a flue blockage safety device which will shut down the fire if abnormal flue conditions occur. It is
NOT a substitute for an independently mounted Carbon Monoxide detector.
• This fire is supplied with a particular style of firefront. Use of the firefront will ensure an adequate airflow under the firebed
for the correct functioning of this appliance. Use ONLY the firefront supplied with the appliance. Use of any other firefront
could be dangerous.
• Should any home improvements be carried out to the property after the fire is installed, such as installation of extractor fans
for example, the fire should be re-checked by a competent person for safe operation.
U S E R I N S T R U C T I O N S
2.0 CLEARANCES TO COMBUSTIBLES
A combustible shelf may be fixed to the wall above the fire, providing that it complies with the dimensions given below.
A non-combustible shelf may be fitted to within 10mm of the top edge of the fireplace opening.
Combustible materials, such as wood, may be fitted to within 100mm of either side of the fireplace opening, providing the for-
ward projection does not exceed 100mm.
Any combustible side walls must be at least 500mm to the side of the radiant heat source.
As with all heating appliances, any decorations, soft furnishings, and wall coverings (i.e. flock, blown vinyl and embossed paper)
positioned too close to the appliance may discolour or scorch.
1.0 IMPORTANT NOTES
1
'
2013 Focal Point Fires plc.
GB IE
Maximum depth of shelf Minimum distance from finished hearth
surface to underside of shelf
100mm
745mm
150mm
845mm
203mm
895mm
Section
1.0
2.0
3.0
4.0
5.0
6.0
6.1
7.0
8.0
Contents
Important Notes
Clearances To Combustilbles
Fire Guards
Servicing
Ventilation
Operating The Fire
(Manual Control Versions)
Operating The Fire
(Remote Control Versions)
Flue Spillage Monitoring Systerm
Fuel Bed Layout
(Coal Effect)
Page No.
1
1
2
2
2
3
3
4
4
Section
8.1
8.2
9.0
10.0
11.0
12.0
13.0
14.0
Contents
Fuel Bed Layout
(Pebble Effect)
Fuel Bed Layout
(Log Effect)
Cleaning
Replacing The Batteries
(Remote
Control Versions)
List Of Replacement Parts
Installation Details
Service History
Guarantee
Page No.
5
7
8
8
8
9
9
9