background image

• The installation and Servicing of this fire MUST only be carried out by a competent person in accordance with local Codes

and/or Regulations, Building Regulations and the manufacturer's instructions. Failure to comply with these could lead to pros-

ecution and invalidate the appliance warranty. In the event of gas leakage from the appliance, the gas supply must be turned off

at the nearest isolating valve. This appliance is only suitable for the gas type for which it is supplied.

• Keep a note of the installer's name and address, GAS SAFE registration number and the original purchase receipt and the date

of installation. Failure to produce this information may invalidate the warranty. The appliance should be serviced regularly to

ensure continued safe operation.  See the servicing section for further reference.

• Parts of this appliance become naturally hot during use. It is recommended that a suitable fireguard is used, especially where

young children, pets, the elderly or infirm are concerned. The manufacturer of this appliance considers all surfaces as working

surfaces with the exception of the control knob and ash pan door.

• As with any gas fire, a fire guard complying with BS 8423 must be used in presence of pets, children, and the

elderly or infirm.

• The appliance should be serviced regularly to ensure continued safe operation. Frequency of service will depend on use, but

MUST be carried out at least once annually.

• Combustible items, such as flooring and furniture and soft wall coverings (such as blown vinyl or embossed paper), low tem-

perature surrounds etc may discolour if fitted too close to the fire. See relevant section for further details on clearances to

combustibles. No combustible materials or flooring should protrude onto the hearth.

• This appliance incorporates a combustion monitoring system (ODS).

• DO NOT burn any foreign material on this fire, the coals must be of the correct type and laid out in accordance with the rel-

evant section of these instructions. Failure to do so could create a hazard or lead to sooting.

• The fire is only suitable for use with the gas type for which it is supplied.

• This appliance is fitted with a flue blockage safety device which will shut down the fire if abnormal flue conditions occur. It is

NOT a substitute for an independently mounted Carbon Monoxide detector.

•  This fire is supplied with a particular style of firefront. Use of the firefront will ensure an adequate airflow under the firebed

for the correct functioning of this appliance. Use ONLY the firefront supplied with the appliance. Use of any other firefront

could be dangerous.

• Should any home improvements be carried out to the property after the fire is installed, such as installation of extractor fans

for example, the fire should be re-checked by a competent person for safe operation.

U S E R     I N S T R U C T I O N S

2.0 CLEARANCES TO COMBUSTIBLES

A combustible shelf may be fixed to the wall above the fire, providing that it complies with the dimensions given below.

A non-combustible shelf may be fitted to within 10mm of the top edge of the fireplace opening.

Combustible materials, such as wood, may be fitted to within 100mm of either side of the fireplace opening, providing the for-

ward projection does not exceed 100mm.

Any combustible side walls must be at least 500mm to the side of the radiant heat source.

As with all heating appliances, any decorations, soft furnishings, and wall coverings (i.e. flock, blown vinyl and embossed paper)

positioned too close to the appliance may discolour or scorch.

1.0 IMPORTANT NOTES

1

'

2013 Focal Point Fires plc.

GB IE

Maximum depth of shelf                       Minimum distance from finished hearth

surface to underside of shelf

100mm

745mm

150mm

845mm

203mm

895mm

Section

1.0

2.0

3.0

4.0

5.0

6.0

6.1

7.0

8.0

Contents

Important Notes

Clearances To Combustilbles

Fire Guards

Servicing

Ventilation

Operating The Fire 

(Manual Control Versions)

Operating The Fire 

(Remote Control Versions)

Flue Spillage Monitoring Systerm

Fuel Bed Layout 

(Coal Effect)

Page No.

1

1

2

2

2

3

3

4

4

Section

8.1

8.2

9.0

10.0
11.0

12.0

13.0

14.0

Contents

Fuel Bed Layout 

(Pebble Effect)

Fuel Bed Layout 

(Log Effect)

Cleaning

Replacing The Batteries 

(Remote

Control Versions)

List Of Replacement Parts

Installation Details

Service History

Guarantee

Page No.

5

7

8

8
8

9

9

9

Содержание HANNINGTON

Страница 1: ...oint Fires plc You are not per mitted to copy or adapt any of the content without the prior written permission of Focal Point Fires plc INTHE UK ALWAYS USE A GAS SAFE REGISTERED ENGINEERTO INSTALL REP...

Страница 2: ...onsiders all surfaces as working surfaces with the exception of the control knob and ash pan door As with any gas fire a fire guard complying with BS 8423 must be used in presence of pets children and...

Страница 3: ...e with an inset Decorative Fuel Effect Fire BS5871 part 3 contains further details The fireplace opening should be inspected and repairs made where nec essary Any chair brick may be left in place The...

Страница 4: ...to unpack or install this appliance Remove the box containing the firefront and the bag containing the coals Remove the cardboard packing pieces and any bags contain ing other fittings or parts Remove...

Страница 5: ...e main burner control shown in figure 3 on left hand side of control valve knob fully anti clockwise Turn ignition knob shown on right hand side of control valve slightly left towards the ignition pos...

Страница 6: ...to the back of the gas control valve may also have worked loose during installation simply tighten to remedy if this is the case If pilot disturbance is not the cause then the ODS safety system may be...

Страница 7: ...with smoke pellet for correct operation 7 Strip off the burner pipes and clean thoroughly 8 Clean out the injector and pilot assembly DO NOT attempt to dismantle the pilot unit 9 Ensure the injector...

Страница 8: ...rthing to metal work reset gap correctly Blocked pilot clean out internally Pilot lights but then goes out Severe restriction in gas supply clear obstruction Faulty thermocouple replace pilot unit Hol...

Страница 9: ...The fire is only suitable for use with the gas type for which it is supplied This appliance is fitted with a flue blockage safety device which will shut down the fire if abnormal flue conditions occur...

Страница 10: ...lowing the instructions given in the Installation section The Installation instructions carry full servicing details for the use of the installer If debris from the flue or other foreign matter is fou...

Страница 11: ...ontrol valve slightly left towards the ignition position until reaching the stop press down and hold for 5 seconds only pilot gas is flowing Continue pressing down the knob while turning further to th...

Страница 12: ...should sit snugly behind the back edge of the burner rails as shown in figure 7 Do not fit the matrix on top of the burner rails 2 Position the front coal strip as shown in figure 8 The rear edge of...

Страница 13: ...of the fuel matrix 6 Finally take the two remaining coals and place at the back of the fuel matrix in the centre as shown in figure 12 Adding these coals should complete the appearance of the fuel be...

Страница 14: ...take another two pebbles and place behind the second row of pebbles next to each other in the centre of the fuel bed as shown in fig ure 16 The pebbles may be orientated as desired to achieve a reali...

Страница 15: ...al ly as shown in figure 21 ensuring correct orientation The base of this log must rest securely on the front log strip Take one of the smaller logs numbered 14 and position in between the two vertica...

Страница 16: ...f handset and insert 1 x PP3 9 volt battery Replace cover Before carrying out any of the following operations ensure that the fire is OFF and completely cold Appliance Ensure appliance is off and cool...

Страница 17: ...nditions for your product have been met then please submit the following information for the attention of the 3G Service Department to the address below Alternatively you can email or fax Please note...

Отзывы: