background image

• This appliance is an Inset Decorative Fuel Effect appliance which provides radiant warmth utilising the latest type burner technology.
• The fire is designed to suit various types of fireplaces and natural draught flues as detailed in this manual.
• The appliance must be installed by a competent person in accordance with Gas Safety (Installation and Use) Regulations 1998. It is
strongly recommended that a GAS SAFE registered engineer be used for this purpose.
• Read all these instructions before commencing installation.
• This appliance must be installed in accordance with the rules in force and used only in a sufficiently ventilated space.
• The appliance is designed for installation on to a non-combustible hearth of at least 300mm depth.
• This appliance is factory set for operation on the gas type, and at the pressure stated on the appliance data plate.
• In the event of gas leakage from the appliance, the gas supply must be turned off at the nearest isolating valve.
• The appliance must be installed in accordance with the following:
• Failure to comply with the above could lead to prosecution and deem the manufacturer’s warranty invalid.
•  The appliance is designed to fit various types of situations as described in sections 3.0 and 4.0.

• It should be noted that heaters create warm air currents.  These currents move heat to wall surfaces next to the heater. Installing the
heater next to vinyl or cloth wall coverings or operating the heater where impurities in the air (such as tobacco smoke, candle smoke
etc.) exist, may cause the walls to become discoloured.
• WARNING: The manufacturer of this appliance considers all surfaces as working surfaces with the exception of the control knob
and ash pan door. 

• As with any gas fire, a fire guard complying with BS 8423 must be used in presence of pets, children, and the elder-

ly or infirm.
• Consult ALL instructions before installation and use of this appliance. 
• This appliance is intended for decorative purposes. 
• This appliance is free from any asbestos material. 
• Refractories and fuel bed are constructed from ceramic fibre.

1.0 IMPORTANT NOTES

I N S T A L L A T I O N   I N S T R U C T I O N S

'

2011 Focal Point Fires plc.

2

GB IE

'

2013 Focal Point Fires plc.

• Manufacturers' Instructions.

• The Building Regulations issued by the Department for Communities and Local Government, the Building Standards  

(Scotland)   

(Consolidation) Regulations issued by the Scottish Development Department.

• Relevant British Standards insofar as the relevant areas are not covered by these instructions.

• For Republic of Ireland, reference should be made to the current edition of IS813 (the relevant standards governing 

installation).

Section

1.0

2.0

3.0

4.0

5.0

6.0

6.1

7.0

8.0

9.0

10.0

11.0

11.1

Contents

Important Notes

Appliance Data

Installation Requirements

Site Requirements

Ventilation

Unpacking the Appliance

Component Checklist

Installing the Burner

Fuel Bed Layout

Fire Front

Testing & Commissioning

Operating the fire 

(Manual Models)

Operating the fire 

(Remote Models)

Page No.

2

3

3

3

4

4

4

4

5

5

5

5

5

Section

12.0

12.1

12.2

12.3

12.3

13.0

13.1

13.2

13.3

13.4

13.5

14.0

Contents

Spark Gap

Operating Pressure

Flue Spillage Monitoring System

Testing For Spillage

Briefing the Customer

Servicing

Cleaning the Ceramics

Removing the Burner

Servicing the Burner

Pilot Assembly

Replacing the Batteries 

(Remote Control Models)

Troubleshooting Guide

User Instructions

Page No.

6

6

6

6

6

6

6

7

8

8

8

8

Содержание HANNINGTON

Страница 1: ...oint Fires plc You are not per mitted to copy or adapt any of the content without the prior written permission of Focal Point Fires plc INTHE UK ALWAYS USE A GAS SAFE REGISTERED ENGINEERTO INSTALL REP...

Страница 2: ...onsiders all surfaces as working surfaces with the exception of the control knob and ash pan door As with any gas fire a fire guard complying with BS 8423 must be used in presence of pets children and...

Страница 3: ...e with an inset Decorative Fuel Effect Fire BS5871 part 3 contains further details The fireplace opening should be inspected and repairs made where nec essary Any chair brick may be left in place The...

Страница 4: ...to unpack or install this appliance Remove the box containing the firefront and the bag containing the coals Remove the cardboard packing pieces and any bags contain ing other fittings or parts Remove...

Страница 5: ...e main burner control shown in figure 3 on left hand side of control valve knob fully anti clockwise Turn ignition knob shown on right hand side of control valve slightly left towards the ignition pos...

Страница 6: ...to the back of the gas control valve may also have worked loose during installation simply tighten to remedy if this is the case If pilot disturbance is not the cause then the ODS safety system may be...

Страница 7: ...with smoke pellet for correct operation 7 Strip off the burner pipes and clean thoroughly 8 Clean out the injector and pilot assembly DO NOT attempt to dismantle the pilot unit 9 Ensure the injector...

Страница 8: ...rthing to metal work reset gap correctly Blocked pilot clean out internally Pilot lights but then goes out Severe restriction in gas supply clear obstruction Faulty thermocouple replace pilot unit Hol...

Страница 9: ...The fire is only suitable for use with the gas type for which it is supplied This appliance is fitted with a flue blockage safety device which will shut down the fire if abnormal flue conditions occur...

Страница 10: ...lowing the instructions given in the Installation section The Installation instructions carry full servicing details for the use of the installer If debris from the flue or other foreign matter is fou...

Страница 11: ...ontrol valve slightly left towards the ignition position until reaching the stop press down and hold for 5 seconds only pilot gas is flowing Continue pressing down the knob while turning further to th...

Страница 12: ...should sit snugly behind the back edge of the burner rails as shown in figure 7 Do not fit the matrix on top of the burner rails 2 Position the front coal strip as shown in figure 8 The rear edge of...

Страница 13: ...of the fuel matrix 6 Finally take the two remaining coals and place at the back of the fuel matrix in the centre as shown in figure 12 Adding these coals should complete the appearance of the fuel be...

Страница 14: ...take another two pebbles and place behind the second row of pebbles next to each other in the centre of the fuel bed as shown in fig ure 16 The pebbles may be orientated as desired to achieve a reali...

Страница 15: ...al ly as shown in figure 21 ensuring correct orientation The base of this log must rest securely on the front log strip Take one of the smaller logs numbered 14 and position in between the two vertica...

Страница 16: ...f handset and insert 1 x PP3 9 volt battery Replace cover Before carrying out any of the following operations ensure that the fire is OFF and completely cold Appliance Ensure appliance is off and cool...

Страница 17: ...nditions for your product have been met then please submit the following information for the attention of the 3G Service Department to the address below Alternatively you can email or fax Please note...