INSTALLATION INSTRUCTIONS

Preliminary Notes Before Installation

This appliance is an Inset live fuel effect gas fire which provides radiant warmth
utilising the latest type burner technology.

The fire is designed to fit various types of fireplaces and natural draught flues as
listed in the Installation Requirements.

The appliance must be installed by a competent person in accordance with
Gas Safety (Installation and Use) Regulations 1998. It is strongly recommended
that a GAS SAFE registered engineer be used for this purpose.

Read all these instructions before commencing installation.

This appliance must be installed in accordance with the rules in force and only
used in a sufficiently ventilated space.

The appliance is designed for installation on to a non-combustible hearth of at
least 300mm depth.

This appliance is factory set for operation on the gas type, and at the pressure
stated on the appliance data plate.

This appliance is available in either a manual control version, or a battery pow-
ered remote control version, with a number of fuel effect options. These
instructions cover both control options, and all fuel effect options. See the rele-
vant sections of these instructions for further details.

©

2010 Focal Point Fires plc.

©

2010 Focal Point Fires plc.

Please note : Except where otherwise stated, all rights, including copyright in the text, images and layout of this booklet is
owned by Focal Point Fires plc.  You are not permitted to copy or adapt any of the content without the prior written permis-
sion of Focal Point Fires plc. 

Содержание Exselsior Multiflue

Страница 1: ...anded to user for safekeeping Revision F 05 10 Country s of destination GB IE Focal Point Fires plc Christchurch Dorset BH23 2BT Tel 01202 499330 Fax 01202 499326 www focalpointfires co uk e mail sale...

Страница 2: ...ed in a sufficiently ventilated space The appliance is designed for installation on to a non combustible hearth of at least 300mm depth This appliance is factory set for operation on the gas type and...

Страница 3: ...are constructed from ceramic fibre Note Remote control models only This appliance features a battery operated remote control system and under normal usage will need new batteries approximately every t...

Страница 4: ...in the flue apart from the one that the appliance is installed into and the one venting the gases into the air A suitable terminal may be fitted such as class GC1 as regulations allow This appliance h...

Страница 5: ...must have a 50mm minimum clearance between it and the back wall of the opening or any other obstruction The area immediately above the outlet must form a smooth path into the flue Any type of fire su...

Страница 6: ...inimum dimensions given in the diagram below are complied with Constructional Note The frame of the fire any back panel or other infill panels and the flue box must be sealed together so that there is...

Страница 7: ...mer and fit the rubber grommet supplied A small incision can now be made in the rubber to slip snugly around the outside of the supply pipe and sleeving Note DO NOT install or use the appliance withou...

Страница 8: ...ts ends The open end of the gas supply pipe should be temporarily sealed to prevent ingress of dust and dirt during installation CABLE FIXING Drill four holes as shown in the diagram and fit the fibre...

Страница 9: ...irefront will clear the supply route If the data control plate is not already fitted attach with two screws ensuring the control knob is free to be depressed fully FUEL BED LAYOUT Coal effect option T...

Страница 10: ...ebbles making sure that the flat sides are firmly against the brick panel and side cheeks as shown Note The pebbles must not be crammed together or inserted into the holes in the matrix A well laid ou...

Страница 11: ...g the ignition procedure To turn the main burner OFF whilst keeping the pilot flame lit turn the ignition control knob to the pilot position then only the pilot will remain lit To shut the fire off co...

Страница 12: ...If the initial spillage test fails run the fire for a further 10 minutes and repeat the test When the test has been complet ed satisfactorily repeat with any extractor fans in the premises running on...

Страница 13: ...tive front and frame Remove the ceramics and the data control plate Remove the two screws securing the tray legs to the firebox Pull tray forward slightly and lift away Refitting is the reverse of abo...

Страница 14: ...plate Missing grommet seal in firebox replace Fire does not spark at pilot HT lead detached refit Spark gap too large or small reset correctly Faulty piezo unit replace Debris shorting out electrode c...

Страница 15: ...er details on clearances to combustibles No combustible material or flooring should protrude onto the hearth DO NOT burn any foreign material on this fire the coals pebbles must be of the correct type...

Страница 16: ...the spark click to the PILOT light position ensuring the pilot has lit If not return the knob clockwise and repeat When the pilot lights after the spark keep the knob depressed for approximately ten s...

Страница 17: ...is OFF and completely cold Debris that may form on the fuelbed should be periodically removed by a competent person Large deposits could indicate deterioration of the flue This should be repaired by...