FLUE SPILLAGE MONITORING SYSTEM

This fire is fitted with a flue spillage safety device (ODS). If the fire shuts down during use for no apparent reason then several things may be
suspected. If a door or window has been opened creating a draught, then pilot disturbance is the problem, and removal of the draught should
resolve this. The gas pressure reaching the fire must also be checked (again, recall your installer to check and rectify any problem). The ther-
mocouple connection into the back of the gas control valve may also have worked loose during installation, simply get the installer to tight-
en.

If pilot disturbance is not the cause, then the ODS safety system may be in operation. Switch the appliance OFF, check the flue and carry out
any remedial work required. Relight the fire and carry out a spillage test. DO NOT allow the appliance to be used if it continues to fail a
spillage test.

The aeration hole of the pilot must be carefully cleaned out on each annual service to ensure continued function of the ODS.

The spillage monitoring system shall not be adjusted, modified, or put out of operation by the installer. Any spare parts fitted MUST be of a
type supplied for the purpose by the appliance manufacturer.

If the fire is not spilling, then further guidance should be sought, using the Troubleshooting section as a guide.

TESTING FOR SPILLAGE

Close all doors and windows to the room containing the appliance. Let the fire run on HIGH for five minutes. Take a smoke match, light it,
and using a smoke match tube, hold it at the top edge of the fire opening, 25mm down and 25mm in. Starting 50mm in from either side, run
the smoke match across the opening. All the smoke should be drawn away up the flue. Any smoke returning into the room indicates that
spillage is occurring. If the initial spillage test fails, run the fire for a further 10 minutes and repeat the test. When the test has been complet-
ed satisfactorily, repeat with any extractor fans in the premises running on the highest   setting, and any communicating doors open. Finally,
repeat with all doors open.

BRIEFING THE CUSTOMER

All instructions must be handed to the user for safekeeping. Show the customer how to light and control the fire.

After commissioning the appliance, the customer should be instructed on the safe use of the appliance and the need for regular servicing.
Frequency of service depends on usage, but MUST be carried out at least once annually.

Advise that cleaning of the fire may be achieved when the fire is cold using a damp cloth and mild detergent on most surfaces.

Scratched and other superficial damage to the matt black paintwork of the appliance can be covered with   matching heatproof spray. Use
only the manufacturers’ recommended spray paint. Paint only when the fire is OFF and cold. Always mask off the surrounding area to pre-
vent contamination with overspray. Ventilate the room during the use of the spray. DO NOT attempt to spray paint the coals/pebbles or
ceramics, or wash them in water.

Advise that the fire will emit a “newness” smell for a time after initial commissioning and that extra ventilation may be needed during this
time. Advise that the fire is fitted with a spillage safety device (O.D.S.). If the fire shuts down, this system may be in operation. If spillage is
suspected, SWITCH APPLIANCE OFF and call in the installer to investigate any problems.

10

12.0

12.1

13.0

C

C

B

A

Fireplace Opening

Smoke Match

In Tube

Match

Crimp

Tube

Cross section of smoke match tube

Make a smoke match tube from 10mm diameter tube.
Seal off one end and crimp the tube to prevent the
smoke match from sliding down inside.

A.25mm down

from top of open-

ing

B. 25mm in from

front of opening.

C. Disregard

outer 50mm

either side of fire-

place opening

©

2010 Focal Point Fires plc.

Содержание Exselsior Multiflue

Страница 1: ...anded to user for safekeeping Revision F 05 10 Country s of destination GB IE Focal Point Fires plc Christchurch Dorset BH23 2BT Tel 01202 499330 Fax 01202 499326 www focalpointfires co uk e mail sale...

Страница 2: ...ed in a sufficiently ventilated space The appliance is designed for installation on to a non combustible hearth of at least 300mm depth This appliance is factory set for operation on the gas type and...

Страница 3: ...are constructed from ceramic fibre Note Remote control models only This appliance features a battery operated remote control system and under normal usage will need new batteries approximately every t...

Страница 4: ...in the flue apart from the one that the appliance is installed into and the one venting the gases into the air A suitable terminal may be fitted such as class GC1 as regulations allow This appliance h...

Страница 5: ...must have a 50mm minimum clearance between it and the back wall of the opening or any other obstruction The area immediately above the outlet must form a smooth path into the flue Any type of fire su...

Страница 6: ...inimum dimensions given in the diagram below are complied with Constructional Note The frame of the fire any back panel or other infill panels and the flue box must be sealed together so that there is...

Страница 7: ...mer and fit the rubber grommet supplied A small incision can now be made in the rubber to slip snugly around the outside of the supply pipe and sleeving Note DO NOT install or use the appliance withou...

Страница 8: ...ts ends The open end of the gas supply pipe should be temporarily sealed to prevent ingress of dust and dirt during installation CABLE FIXING Drill four holes as shown in the diagram and fit the fibre...

Страница 9: ...irefront will clear the supply route If the data control plate is not already fitted attach with two screws ensuring the control knob is free to be depressed fully FUEL BED LAYOUT Coal effect option T...

Страница 10: ...ebbles making sure that the flat sides are firmly against the brick panel and side cheeks as shown Note The pebbles must not be crammed together or inserted into the holes in the matrix A well laid ou...

Страница 11: ...g the ignition procedure To turn the main burner OFF whilst keeping the pilot flame lit turn the ignition control knob to the pilot position then only the pilot will remain lit To shut the fire off co...

Страница 12: ...If the initial spillage test fails run the fire for a further 10 minutes and repeat the test When the test has been complet ed satisfactorily repeat with any extractor fans in the premises running on...

Страница 13: ...tive front and frame Remove the ceramics and the data control plate Remove the two screws securing the tray legs to the firebox Pull tray forward slightly and lift away Refitting is the reverse of abo...

Страница 14: ...plate Missing grommet seal in firebox replace Fire does not spark at pilot HT lead detached refit Spark gap too large or small reset correctly Faulty piezo unit replace Debris shorting out electrode c...

Страница 15: ...er details on clearances to combustibles No combustible material or flooring should protrude onto the hearth DO NOT burn any foreign material on this fire the coals pebbles must be of the correct type...

Страница 16: ...the spark click to the PILOT light position ensuring the pilot has lit If not return the knob clockwise and repeat When the pilot lights after the spark keep the knob depressed for approximately ten s...

Страница 17: ...is OFF and completely cold Debris that may form on the fuelbed should be periodically removed by a competent person Large deposits could indicate deterioration of the flue This should be repaired by...

Страница 18: ......

Страница 19: ......

Страница 20: ......

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ......

Страница 25: ......

Отзывы: