![Focal 922-MES Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/focal/922-mes/922-mes_user-manual_2313663038.webp)
Model 922-MES
– User Manual
Focal Technologies Corporation
Page 9-1
A Moog Inc. Company
Document No. 922-0662-00, Rev 1.0
9.0
Diagnostics and Control
Remotely accessible, real-time diagnostic data and status information is available from the 922-MES. This
information can be used for real-time health monitoring and long-term trending of critical parameters for
predictive analysis.
Ethernet Diagnostics (Modbus TCP/IP and Telnet):
The Ethernet interface provides full diagnostics and
control of the card. Diagnostics and status information are retrievable using Modbus TCP/IP and/or Telnet over
any Ethernet port (copper or SFP).
Configuration options include:
Ethernet port control registers (e.g. forcing speed/duplex, rate limiting, aging, broadcast protection,
port priority, virtual local area network (VLAN) configuration, etc.)
Field update of embedded firmware, and user-controlled switching between stored firmware versions.
Factory Serial Diagnostics (RS-232):
The RS-232 serial interface provides basic read-only diagnostics
information via a non-isolated interface (J3). It is intended for factory bench testing and debugging purposes
only. See section 6.6 for details.
Diagnostics information and control provided by the card is shown in the table below.
Table 9-1: Diagnostics Information
Diagnostics Type
Description
Ethernet
Telnet
Modbus
UDP
(long)
UDP
(short)
Ethernet Copper Ports
Link speed status (10/100/1000M)
Link speed configuration (10/100/1000M)
Duplex mode
Autonegotiation state
Ethernet SFP Ports
Link speed (100/1000M)
Link speed configuration (100/1000M)
Redundancy Mode
MRP Status (MRC/MRM SFPs only)
MRP configuration
RSTP Status (Copper ports only)
RSTP configuration
Optical SFP
Optical Tx/Rx power levels, Tx bias current, voltage
and temperature
Serial number and wavelength
On-board Sensors
Board temperature
Humidity
ON time counter
OFF event counter
Network, Analog Data and
Board Serials
Network settings and configuration (IP address,
Subnet Mask, Gateway, DNS, DHCP)
Analog data (on-board voltage rails and board current)
Board serial information (including serial number, date
code, FW version, MAC address)
Notes:
1.
Diagnostics data shown is for cards with uC DIAG FW version
≥
0xA3
where
= Diagnostics capability available. Blank =
Diagnostics capability not available.