Focal 922-MES Скачать руководство пользователя страница 23

 

 

Model 922-MES 

– User Manual 

 

Focal Technologies Corporation

 

 

Page 6-4

 

A Moog Inc. Company 

 

Document No. 922-0662-00, Rev 1.0

 

6.4  Connector Part Numbers 

The 922-MES connectors and their mating connector part number is shown below. 

Table 6-3: Connector/Mating Connector Part Numbers 

On-board Connector 

Mating Connector 

Ref 

Description 

Manufacturer 

Manufacturer Part Number 

Manufacturer Part Number 

J11 

96-Pin DIN 41612 

Harting 

0903-196-6921 

09032966824 (Vert. PCB Mount) 

J3 

3.5 mm Stereo Jack 

CUI Inc. 

SJ1-3523NG 

SP-3501 

6.5  96-pin DIN 41612 Backplane Connector (J11) 

A  96-pin  DIN  41612  backplane  connector  provides  access  to  eight  (8)  copper  ports  (CU1-CU8)  and  power 
interface. 

 

Figure 6-3: DIN 41612 (96-pin) Backplane Connector (Front View) 

Table 6-4: DIN 41642 (96-pin) Backplane Connector Pin-out 

Pin 

Name 

Row A 

Row B 

Row C 

DA+_CU1 

REF_CU1 

DB+_CU1 

DA-_CU1 

REF_CU1 

DB-_CU1 

DC+_CU1 

DB+_CU5 

DD+_CU1 

DC-_CU1 

DB-_CU5 

DD-_CU1 

DA+_CU5 

DC+_CU5 

DD+_CU5 

DA-_CU5 

DC-_CU5 

DD-_CU5 

VIN1+ 

VIN1+ 

VIN1+ 

VIN2+ 

VIN2+ 

VIN2+ 

DC-_CU2 

DC+_CU2 

REF_CU5 

10 

VIN- 

VIN- 

VIN- 

11 

VIN- 

VIN- 

VIN- 

12 

DD+_CU2 

DD-_CU2 

REF_CU5 

13 

DA+_CU2 

DB+_CU2 

REF_CU2 

14 

DA-_CU2 

DB-_CU2 

REF_CU2 

15 

DA+_CU3 

DB+_CU3 

REF_CU3 

16 

DA-_CU3 

DB-_CU3 

REF_CU3 

17 

DA+_CU6 

DD+_CU3 

DC+_CU3 

18 

DA-_CU6 

DD-_CU3 

DC-_CU3 

19 

DC+_CU6 

DB+_CU6 

REF_CU6 

20 

DC-_CU6 

DB-_CU6 

REF_CU6 

21 

DA+_CU7 

DB+_CU7 

DD+_CU6 

22 

DA-_CU7 

DB-_CU7 

DD-_CU6 

23 

DC+_CU7 

REF_CU7 

DD+_CU7 

24 

DC-_CU7 

REF_CU7 

DD-_CU7 

25 

DA+_CU8 

DB+_CU8 

DD+_CU8 

26 

DA-_CU8 

DB-_CU8 

DD-_CU8 

27 

DC+_CU8 

DC+_CU4 

REF_CU8 

28 

DC-_CU8 

DC-_CU4 

REF_CU8 

29 

DA+_CU4 

DB+_CU4 

REF_CU4 

30 

NC 

NC 

DD+_CU4 

31 

DA-_CU4 

DB-_CU4 

REF_CU4 

32 

NC

 

NC

 

DD-_CU4

 

Notes: 
1. 

NC = No Connect 

2. 

VIN1+ (24V ) and VIN2+ (24V ) are independent power inputs, each with reverse protection diodes and can be 
connected to separate power supplies or both from one power supply.

 

 

C

B

A

1

32

Содержание 922-MES

Страница 1: ...GRANTED BY CONTRACT OR BY OPERATION OF LAW NO PORTION OF THIS DATA DRAWING DOCUMENT SHALL BE REPRODUCED OR DISCLOSED OR COPIED OR FURNISHED IN WHOLE OR IN PART TO OTHERS OR USED BY OTHERS FOR ANY PURP...

Страница 2: ...ion Details of Revision Author s Date yyyy mm dd Rev 1 Initial release ACC 2018 01 29 Reference Documents Document Number Document Title and Description 922 2005 00 Configuration Drawing Model 922 MES...

Страница 3: ...s 6 4 6 5 96 pin DIN 41612 Backplane Connector J11 6 4 6 6 3 5 mm Jack Factory Diagnostics Port J3 6 5 6 7 LED Connector J5 6 5 6 8 Electrical Interfaces 6 6 6 8 1 24V Power Input 6 6 6 8 2 Ethernet I...

Страница 4: ...t Content From uC DIAG 8 7 Table 9 1 Diagnostics Information 9 1 LIST OF FIGURES Figure 1 1 Model 922 MES 1 1 Figure 3 1 Model 922 MES Ethernet Ports 3 1 Figure 3 2 Model 922 MES Block Diagram and Por...

Страница 5: ...sation LED Light Emitting Diode MAC Media Access Control Ethernet MES Managed Ethernet Switch MTBF Mean Time between Failures MIB Management Information Base MRC Media Redundancy Client MRM Media Redu...

Страница 6: ...t No 922 0662 00 Rev 1 0 SMT Surface Mount Technology STP Spanning Tree Protocol or Shielded Twisted Pair cable TCP Transmission Control Protocol TTL Transistor Transistor Logic uC Microcontroller UDP...

Страница 7: ...iple cards within a distribution unit or SEM Redundancy protocols supported by the MES include MRP Media Redundancy Protocol and RSTP Rapid Spanning Tree Protocol Advanced diagnostics provide real tim...

Страница 8: ...lengths 1471 to 1611 nm Optical Power Budget 20 to 45 dB depending on SFP installed Range 10 to 200 km depending on SFP installed Options Bidirectional single fiber transceivers 1 See Subsea Qualified...

Страница 9: ...operation The Ethernet ports and media types available for the MES is shown in the figure below Figure 3 1 Model 922 MES Ethernet Ports The 922 MES PCB has a Eurocard form factor with a 96 pin DIN hea...

Страница 10: ...l P2 CU1 User External P3 CU2 User External P4 CU3 User External P5 CU4 User External P6 CU5 User External P7 CU6 User External P8 CU7 User External P9 CU8 User External Connection types shown as User...

Страница 11: ...cally daisy chaining the second card can provide a second pair of optical connections for other subsea nodes With RSTP functionality enabled in the MES the copper ports can also be used to electricall...

Страница 12: ...switch are set by a combination of installed optical transceivers and switch register settings The Ethernet switch settings may be changed from their default settings using a Modbus TCP connection to...

Страница 13: ...which are sent automatically by the card every 5 seconds factory default The MES card also includes a remote firmware upgrade feature which offers an upgrade path to support future protocols or appli...

Страница 14: ...oftware Link Speed 10BASE T 100BASE TX 1000BASE T 10BASE T 100BASE TX 1000BASE T Duplex Mode Full Duplex or Half Duplex Full Duplex Negotiation Autonegotiation Enabled Disabled Autonegotiation Enabled...

Страница 15: ...ttings from A EEPROM user factory configuration or B Fail safe factory Option A Future Use Factory Reserved Parameters Software Reserved Network IP address 192 168 0 201 Subnet 255 255 255 0 Gateway 1...

Страница 16: ...nd CU1 or any other copper port of the card under configuration 2 Power up the card 24 VDC Note The card boot up time is about 1 5 minutes and on board LEDs will indicate a physical link after this pe...

Страница 17: ...TP changes etc Note that in the Model 922 Config Editor window changes made by the user will only take effect after the Save Configuration button is pressed and after one subsequent power cycle To mak...

Страница 18: ...sub rack card cage or wiring harness using a 96 pin DIN 41612 connector This connector provides the interface for power and eight 8 copper Ethernet ports On the front of the PCBA are two 2 SFP ports a...

Страница 19: ...ck connections If the card is intended to be used for extended periods beyond 40 C ambient other heat dissipation or heatsink options should be considered to extended product life Contact the factory...

Страница 20: ...ry testing headers and jumpers may not be exactly as shown REF DESCRIPTION SFP1 2 SFP CAGES ETHERNET SFP1 2 JP2 uC DIAG CODE RESET J3 FACTORY DIAGNOSTICS CONNECTOR RS 232 J5 LED HEADER I2C J11 DIN 416...

Страница 21: ...00 Rev 1 0 The 922 MES card has three 3 unique MAC addresses used for diagnostics MAC UC and Ethernet switching functions MAC PS and MAC PL The location of the serial number and MAC addresses labels a...

Страница 22: ...LINK 3 D23 CU6 ACTIVITY 4 D24 CU7 LINK 3 D25 CU7 ACTIVITY 4 D26 CU8 LINK 3 D27 CU8 ACTIVITY 4 Notes 1 Green ON Solid No loss of optical signal No LOS OFF Loss of optical signal LOS 2 Green ON Solid B...

Страница 23: ..._CU1 REF_CU1 DB _CU1 2 DA _CU1 REF_CU1 DB _CU1 3 DC _CU1 DB _CU5 DD _CU1 4 DC _CU1 DB _CU5 DD _CU1 5 DA _CU5 DC _CU5 DD _CU5 6 DA _CU5 DC _CU5 DD _CU5 7 VIN1 VIN1 VIN1 8 VIN2 VIN2 VIN2 9 DC _CU2 DC _...

Страница 24: ...ort is an output only and writing to this port is not supported and will have no effect CAUTION This RS 232 serial diagnostics port is non isolated and it is intended for bench testing and factory deb...

Страница 25: ...w shows the input protection diodes common mode EMC filter and DC DC converter Power input must be within 20VDC to 28VDC Ideal input voltage is 24VDC and provided by a supply with a Safety Extra Low V...

Страница 26: ...heat plate in place If required these five holes can also be accessed by reconfiguring the heat plate hardware Please consult the factory for recommendations Figure 6 6 Mounting Holes Locations Refere...

Страница 27: ...with 100 km range Contact the factory for qualified SFP options and for instructions on installation 7 2 Optical Fiber The card communicates using up to two SFP transceivers per card which requires up...

Страница 28: ...cal power so a fixed attenuator is recommended even when using a VOAT to ensure a minimum attenuation at all times Adding attenuators for bench testing simulates only the insertion loss of a field sys...

Страница 29: ...ve dust covers on fiber connectors and bushings when not in use Do not touch the white ceramic ferrules of the connectors with bare hands or objects other than cleaning materials Prior to making a fib...

Страница 30: ...for future protocols or application specific requirements 8 1 Network Settings and Accessibility 8 1 1 IP Address Configuration Each 922 MES board is assigned with three unique MAC addresses during f...

Страница 31: ...the MES cards are shipped from the factory with MRP enabled in MRC mode which allows the use of the two SFP ports at the same time When connecting two MES card ports via both SFP ports for redundancy...

Страница 32: ...2 MES core FW 922 1008 55 supports RSTP on all ports SFP1 2 and CU1 8 and does not provide MRP functionality on the SFP1 2 ports The RSTP features included in the MES are Very low latency Ethernet pa...

Страница 33: ...al Technologies Corporation Page 8 4 A Moog Inc Company Document No 922 0662 00 Rev 1 0 IEEE 1588 v2 PTP E2E Management Information Base MIB Counters Detailed description of these features is availabl...

Страница 34: ...switch configurations from into an EEPROM The current Ethernet switch configuration can be saved to the EEPROM via a Telnet and or Modbus TCP IP interface The user can also revert back to the factory...

Страница 35: ...OM The EEPROM is configured at the factory for full switching functionality The user can modify most of the factory pre defined values to accommodate specific requirements and network topologies The i...

Страница 36: ...adjusted to any value between 1 and 253 seconds through Telnet The table below shows an example of the diagnostics information contained in each type of UDP packet The heartbeat packet type can be cha...

Страница 37: ...DIAG The MES card includes an IP validation feature in the Telnet interface This feature checks for a valid IP and subnet combination If an invalid IP Address is entered using the set ip command the...

Страница 38: ...a a non isolated interface J3 It is intended for factory bench testing and debugging purposes only See section 6 6 for details Diagnostics information and control provided by the card is shown in the...

Страница 39: ...3 02 9 2 Telnet Interface The 922 MES card implements a Telnet server on port 23 The server can be accessed from a PC based Telnet client such as Microsoft Telnet ClientTM or Tera Term by entering the...

Страница 40: ...use on Microsoft Windows with a Modbus TCP backend for integration and bench testing the Model 922 Modbus functionality Typically users have or develop their own Modbus TCP interfaces for local PLCs a...

Отзывы: