8.4.4  Software Reset 

The MES card supports soft resets to the diagnostics microcontroller (uC DIAG) and to the MES switch core for 
a full system reset. These soft resets can be applied to the card via Telnet commands.  
 
A uC DIAG soft reset will re-initialize the diagnostics microcontroller interface and peripherals. 
 
An MES switch core soft reset will reset the MES switch. This system reset will re-initialize the MES operating 
system and switch fabric and will also re-load the last saved EEPROM configuration. The system reset will cause 
an Ethernet link disconnection on all ports of the MES and start a standard  boot up sequence that lasts about 
1.5 min.  
 

Notes: 

1.  Any software changes made to the MES not saved in EEPROM will revert back to the last saved state. 
2.  In the current diagnostics firmware version, an MES switch core reset (Telnet command: 

bp reboot

must be followed by  a  uC  DIAG soft reset (Telnet command: 

reset

) 5 sec. (min.) to 10 sec. (max.) 

later. Missing this time window will require a power cycle to the card to re-connect to diagnostics. 

8.4.5  Watchdog Reset 

The  card  has  a  built  in  watchdog  timers  which  are  used  to  trigger  a  uC  DIAG  watchdog  reset  in  case  of  a 
diagnostics lock up or to trigger a watchdog reset in case of an MES switch core operating system lock up. 

 
Note

: The exact timing parameters of the watchdog reset are beyond the scope of this document.

 

8.4.6  Automatic User Switch Configuration Loading 

The card automatically loads its configuration from EEPROM. The EEPROM is configured at the factory for full 
switching  functionality.  The  user  can  modify  most  of  the  factory  pre-defined  values  to  accommodate  specific 
requirements and network topologies.  
 
The initial user configuration of the card can be done via the Telnet interface or via the sample GUI, and changes 
can be saved into the EEPROM such that on power up the MES switch core can load its configuration as defined 
by the user.  
 

Note that the user has to make sure that they save a valid switch configuration in the EEPROM. Failure 
to do so may result in loss of connectivity to the card.

 

 

MES cards with uC DIAG firmware 922-1008-00 version 

≥ 0xA3 

 
Cards with diagnostics firmware version 

≥0xA3 support saving card configuration changes to EEPROM via the 

Telnet interface and also via Modbus. EEPROM changes made via Modbus require user confirmation after a 
power cycle to take permanent effect, without user confirmation the card will return to the previous state after a 
second power cycle. This behavior allows the user a second chance to confirm the full switch functionality of the 
card before making them permanent and also allows the user to go back to a previous switch configuration state. 
 

Extended User Switch Configuration 
 

In  cases  where  additional  switch  settings  are  needed,  the  diagnostics  microcontroller  (uC  DIAG)  allows  the 
end-user  to  automatically  load  extended  switch  and  system  configuration  options  from  EEPROM.  This 
functionality can be enabled or disabled through the Telnet interface by sending a “

scfg on

” or “

scfg off

” 

command. If  this  feature  is  enabled, then  on  power-up  and  after  the  uC  DIAG  is  running  and  after  the  basic 
switch configuration is loaded, the card will load the extended switch configuration from the EEPROM after ~40 
seconds. By default this option is disabled. 
 

 

 

Содержание 922-MES

Страница 1: ...GRANTED BY CONTRACT OR BY OPERATION OF LAW NO PORTION OF THIS DATA DRAWING DOCUMENT SHALL BE REPRODUCED OR DISCLOSED OR COPIED OR FURNISHED IN WHOLE OR IN PART TO OTHERS OR USED BY OTHERS FOR ANY PURP...

Страница 2: ...ion Details of Revision Author s Date yyyy mm dd Rev 1 Initial release ACC 2018 01 29 Reference Documents Document Number Document Title and Description 922 2005 00 Configuration Drawing Model 922 MES...

Страница 3: ...s 6 4 6 5 96 pin DIN 41612 Backplane Connector J11 6 4 6 6 3 5 mm Jack Factory Diagnostics Port J3 6 5 6 7 LED Connector J5 6 5 6 8 Electrical Interfaces 6 6 6 8 1 24V Power Input 6 6 6 8 2 Ethernet I...

Страница 4: ...t Content From uC DIAG 8 7 Table 9 1 Diagnostics Information 9 1 LIST OF FIGURES Figure 1 1 Model 922 MES 1 1 Figure 3 1 Model 922 MES Ethernet Ports 3 1 Figure 3 2 Model 922 MES Block Diagram and Por...

Страница 5: ...sation LED Light Emitting Diode MAC Media Access Control Ethernet MES Managed Ethernet Switch MTBF Mean Time between Failures MIB Management Information Base MRC Media Redundancy Client MRM Media Redu...

Страница 6: ...t No 922 0662 00 Rev 1 0 SMT Surface Mount Technology STP Spanning Tree Protocol or Shielded Twisted Pair cable TCP Transmission Control Protocol TTL Transistor Transistor Logic uC Microcontroller UDP...

Страница 7: ...iple cards within a distribution unit or SEM Redundancy protocols supported by the MES include MRP Media Redundancy Protocol and RSTP Rapid Spanning Tree Protocol Advanced diagnostics provide real tim...

Страница 8: ...lengths 1471 to 1611 nm Optical Power Budget 20 to 45 dB depending on SFP installed Range 10 to 200 km depending on SFP installed Options Bidirectional single fiber transceivers 1 See Subsea Qualified...

Страница 9: ...operation The Ethernet ports and media types available for the MES is shown in the figure below Figure 3 1 Model 922 MES Ethernet Ports The 922 MES PCB has a Eurocard form factor with a 96 pin DIN hea...

Страница 10: ...l P2 CU1 User External P3 CU2 User External P4 CU3 User External P5 CU4 User External P6 CU5 User External P7 CU6 User External P8 CU7 User External P9 CU8 User External Connection types shown as User...

Страница 11: ...cally daisy chaining the second card can provide a second pair of optical connections for other subsea nodes With RSTP functionality enabled in the MES the copper ports can also be used to electricall...

Страница 12: ...switch are set by a combination of installed optical transceivers and switch register settings The Ethernet switch settings may be changed from their default settings using a Modbus TCP connection to...

Страница 13: ...which are sent automatically by the card every 5 seconds factory default The MES card also includes a remote firmware upgrade feature which offers an upgrade path to support future protocols or appli...

Страница 14: ...oftware Link Speed 10BASE T 100BASE TX 1000BASE T 10BASE T 100BASE TX 1000BASE T Duplex Mode Full Duplex or Half Duplex Full Duplex Negotiation Autonegotiation Enabled Disabled Autonegotiation Enabled...

Страница 15: ...ttings from A EEPROM user factory configuration or B Fail safe factory Option A Future Use Factory Reserved Parameters Software Reserved Network IP address 192 168 0 201 Subnet 255 255 255 0 Gateway 1...

Страница 16: ...nd CU1 or any other copper port of the card under configuration 2 Power up the card 24 VDC Note The card boot up time is about 1 5 minutes and on board LEDs will indicate a physical link after this pe...

Страница 17: ...TP changes etc Note that in the Model 922 Config Editor window changes made by the user will only take effect after the Save Configuration button is pressed and after one subsequent power cycle To mak...

Страница 18: ...sub rack card cage or wiring harness using a 96 pin DIN 41612 connector This connector provides the interface for power and eight 8 copper Ethernet ports On the front of the PCBA are two 2 SFP ports a...

Страница 19: ...ck connections If the card is intended to be used for extended periods beyond 40 C ambient other heat dissipation or heatsink options should be considered to extended product life Contact the factory...

Страница 20: ...ry testing headers and jumpers may not be exactly as shown REF DESCRIPTION SFP1 2 SFP CAGES ETHERNET SFP1 2 JP2 uC DIAG CODE RESET J3 FACTORY DIAGNOSTICS CONNECTOR RS 232 J5 LED HEADER I2C J11 DIN 416...

Страница 21: ...00 Rev 1 0 The 922 MES card has three 3 unique MAC addresses used for diagnostics MAC UC and Ethernet switching functions MAC PS and MAC PL The location of the serial number and MAC addresses labels a...

Страница 22: ...LINK 3 D23 CU6 ACTIVITY 4 D24 CU7 LINK 3 D25 CU7 ACTIVITY 4 D26 CU8 LINK 3 D27 CU8 ACTIVITY 4 Notes 1 Green ON Solid No loss of optical signal No LOS OFF Loss of optical signal LOS 2 Green ON Solid B...

Страница 23: ..._CU1 REF_CU1 DB _CU1 2 DA _CU1 REF_CU1 DB _CU1 3 DC _CU1 DB _CU5 DD _CU1 4 DC _CU1 DB _CU5 DD _CU1 5 DA _CU5 DC _CU5 DD _CU5 6 DA _CU5 DC _CU5 DD _CU5 7 VIN1 VIN1 VIN1 8 VIN2 VIN2 VIN2 9 DC _CU2 DC _...

Страница 24: ...ort is an output only and writing to this port is not supported and will have no effect CAUTION This RS 232 serial diagnostics port is non isolated and it is intended for bench testing and factory deb...

Страница 25: ...w shows the input protection diodes common mode EMC filter and DC DC converter Power input must be within 20VDC to 28VDC Ideal input voltage is 24VDC and provided by a supply with a Safety Extra Low V...

Страница 26: ...heat plate in place If required these five holes can also be accessed by reconfiguring the heat plate hardware Please consult the factory for recommendations Figure 6 6 Mounting Holes Locations Refere...

Страница 27: ...with 100 km range Contact the factory for qualified SFP options and for instructions on installation 7 2 Optical Fiber The card communicates using up to two SFP transceivers per card which requires up...

Страница 28: ...cal power so a fixed attenuator is recommended even when using a VOAT to ensure a minimum attenuation at all times Adding attenuators for bench testing simulates only the insertion loss of a field sys...

Страница 29: ...ve dust covers on fiber connectors and bushings when not in use Do not touch the white ceramic ferrules of the connectors with bare hands or objects other than cleaning materials Prior to making a fib...

Страница 30: ...for future protocols or application specific requirements 8 1 Network Settings and Accessibility 8 1 1 IP Address Configuration Each 922 MES board is assigned with three unique MAC addresses during f...

Страница 31: ...the MES cards are shipped from the factory with MRP enabled in MRC mode which allows the use of the two SFP ports at the same time When connecting two MES card ports via both SFP ports for redundancy...

Страница 32: ...2 MES core FW 922 1008 55 supports RSTP on all ports SFP1 2 and CU1 8 and does not provide MRP functionality on the SFP1 2 ports The RSTP features included in the MES are Very low latency Ethernet pa...

Страница 33: ...al Technologies Corporation Page 8 4 A Moog Inc Company Document No 922 0662 00 Rev 1 0 IEEE 1588 v2 PTP E2E Management Information Base MIB Counters Detailed description of these features is availabl...

Страница 34: ...switch configurations from into an EEPROM The current Ethernet switch configuration can be saved to the EEPROM via a Telnet and or Modbus TCP IP interface The user can also revert back to the factory...

Страница 35: ...OM The EEPROM is configured at the factory for full switching functionality The user can modify most of the factory pre defined values to accommodate specific requirements and network topologies The i...

Страница 36: ...adjusted to any value between 1 and 253 seconds through Telnet The table below shows an example of the diagnostics information contained in each type of UDP packet The heartbeat packet type can be cha...

Страница 37: ...DIAG The MES card includes an IP validation feature in the Telnet interface This feature checks for a valid IP and subnet combination If an invalid IP Address is entered using the set ip command the...

Страница 38: ...a a non isolated interface J3 It is intended for factory bench testing and debugging purposes only See section 6 6 for details Diagnostics information and control provided by the card is shown in the...

Страница 39: ...3 02 9 2 Telnet Interface The 922 MES card implements a Telnet server on port 23 The server can be accessed from a PC based Telnet client such as Microsoft Telnet ClientTM or Tera Term by entering the...

Страница 40: ...use on Microsoft Windows with a Modbus TCP backend for integration and bench testing the Model 922 Modbus functionality Typically users have or develop their own Modbus TCP interfaces for local PLCs a...

Отзывы: