8.2 OPERATING THE APPLIANCE

9.0 BRIEFING THE CUSTOMER

1. Lay out the dustsheet and tools.

2. Remove the control handle and the decorative casting assembly. See section 7.1. 

3. Remove the glass door assembly (4 screws) and clean carefully.

4. Inspect the burner, ceramics and the catalyst and clean if necessary with a soft brush.

5. Disconnect the gas supply.

6. Undo the two screws retaining the burner assembly to the left and right hand side of the firebox. 

7. Remove the burner unit, strip off the burner pipes and clean thoroughly.

8. Clean the injector, pilot assembly and the burner tube. Do not attempt to remove the pilot injector as this can cause damage.

9. Re-assemble components.

10. Turn on the gas supply and leak test. Check pilot and burner for good ignition.

11. Refit the glass door assembly, ensuring correct orientation and a good seal.

12. Refit the decorative casting assembly. Installation is reverse of section 7.1. 

13. Check the purpose provided ventilation is un-obstructed.

14. Light the fire and test the operating pressures.

15. Check safe operation of the appliance by performing a combustion test as detailed in section 10.3.  

For specific servicing instructions, see relevant sections.

10.0 SERVICING

8

GB IE

The control handle is located in the centre of the appliance. The

control handle is marked as shown in figure 18.

The pilot is visible behind the centre of the burner. 

Move the control handle fully right to the SPARK position, and hold

there for approximately ten seconds. Now release the control han-

dle and the pilot should stay alight. When the pilot light has estab-

lished, move the control handle left to the LOW flame setting. If the

pilot is extinguished during use, wait three minutes before repeating

the  ignition  procedure.  To  achieve  the  HIGH  setting,  move  the

control handle left to the HIGH flame setting.  The fire can also be

set to operate anywhere between HIGH and LOW by moving the control handle to an intermediate position. 

To turn the fire OFF, move the control handle left fully to the position marked ‘O’.

Figure 18

8.3 OPERATING PRESSURE

The pressure test point is located on the inlet restrictor elbow in the

centre of the burner as shown in figure 19.

Release the pressure test point screw, and attach a pressure gauge.

Light the fire on the HIGH setting. To commission the appliance, the

operating pressure must be in accordance with the figures stated in

section 2.0 of these instructions. The fire is factory set to achieve the

correct flow rates at the specified inlet pressure. 

Any  significant  variation  in  the  operating  pressure  could  indicate  a

supply  problem.  If  the  inlet  pressure  is  too  high,  the  gas  supply

meter/governor may be set incorrectly.

This should be checked with the fire running and if necessary reset by

the gas supplier. If the operating pressure is too low, then check the

meter/governor pressure with the appliance running. If this is less than

the inlet pressure stated in section 2.0 of these instructions it will

need to be reset by the gas supplier. If the inlet pressure is too low, but the meter/governor pressure is acceptable, then a problem in

the supply pipework is to be suspected.  

Upon satisfactory checking of the inlet pressure, turn the fire off, disconnect the pressure gauge and refit the test point screw. Light the

fire and check for gas soundness. In the event that the inlet pressure is not in accordance with the figures stated in the data section of

these instructions, the appliance must not be commissioned, and the problem investigated and rectified.

Figure 19

All instructions must be handed to the user for safekeeping. Show the customer how to light and control the fire. 

After commissioning the appliance, the customer should be instructed on the safe use of the appliance and the need for regular servic-

ing.  Frequency of service depends on usage, but MUST be carried out at least once annually.

Advise that cleaning of the fire may be achieved when the fire is cold using a damp cloth and mild detergent on most surfaces.  Advise

that on first light up of a new appliance, initial curing of high temperature paint and burning off of lubricants may occur for the first few

hours  of  operation.  During  this  period  some  smoke  may  be  emitted  from  the  outlet  grille,  this  should  be  no  cause  for  concern.

Accordingly, the room should be well ventilated with all windows and doors open during this period. During this period the appliance

may cause smoke alarms to sound. If this happens, reset the alarms, but do not remove the batteries.  Recommend that a guard be used

for the protection of the young, pets, the elderly and the infirm. Advise the customer that the ventilation openings should not be blocked

or obstructed in any way. IMPORTANT; Show the customer where the battery compartment is and how to change the battery.

Isolate the fire from the gas supply.  Ensure that the fire is fully cold before attempting service.  

A suggested procedure for servicing is detailed below.

© 2014 Focal Point Fires plc.

Содержание DALVIK

Страница 1: ...ritten per mission of Focal Point Fires plc 1 Revision B 11 14 GB IE INTHE UK ALWAYS USE A GAS SAFE REGISTERED ENGINEERTO INSTALL REPAIR OR SERVICETHIS APPLIANCE MODEL SHOWN DALVIK FLUELESS STOVE LEIR...

Страница 2: ...form of background heating present If the appliance is used in a room as the sole source of heat then condensation may occur on colder surfaces within the room On first light up of a new appliance bur...

Страница 3: ...e in cubic feet ft3 by 35 3 This appliance may be installed in any room in the home except bathrooms In accordance with BS5871 part 4 installation in bedrooms is permitted If the appliance is to be in...

Страница 4: ...ends on the depth or protrusion from the wall of the TV but must extend at least 50mm outward from the front of the TV See figure 5 If a minimum distance of 50mm to the TV from the shelf front cannot...

Страница 5: ...UNPACKING THE APPLIANCE Remove the outer packaging remove any instructions Read ALL these instructions before continuing to unpack or install this appliance Lift off the remaining packaging components...

Страница 6: ...ront casting using the M6 x 15mm screw supplied 9 To re assemble the castings read instructions in reverse order 10 Attach the control handle to the burner assembly through the opening in the front pa...

Страница 7: ...t be lit manually Figure 17 Spark gap Turn on and test the gas supply up to the fire for any leaks in accordance with the current edition of BS 6891 natural gas installations or the current edition of...

Страница 8: ...section 2 0 of these instructions The fire is factory set to achieve the correct flow rates at the specified inlet pressure Any significant variation in the operating pressure could indicate a supply...

Страница 9: ...val Ensure setting pressures are as stated in Section 2 Appliance Data It is recommended that the catalysts are inspected for signs of damage and dirt during routine servicing procedures The expected...

Страница 10: ...aft Fire is too close to an air vent Fire is sited on disused chimney breast which has not been adequately sealed up Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly Pilot lig...

Страница 11: ...servicing section for further reference The guard glass front is to prevent the risk of fire or injury from burns and no part of it should be permanently removed It Does Not Give Full Protection ForYo...

Страница 12: ...d be properly de commissioned and sealed at the base using non com bustible materials The old flue should be ventilated to prevent condensation and possible damage to the fabric of the building This v...

Страница 13: ...or can be moveable and can be used with open fires including combination grates or closed fires including room heaters and stoves See figures 6 7 for fireguard examples The fireguards specified are n...

Страница 14: ...is visible behind the centre of the burner Move the control handle fully right to the SPARK position and hold there for approximately ten seconds Now release the control han dle and the pilot should s...

Страница 15: ...reate dust from the logs Where neces sary replace damaged components with genuine spares Seal scrap components in plastic bags and dispose of at proper refuse sites as directed 10 0 REPLACING THE BATT...

Страница 16: ...GAS SAFE registration No Model Fire serial No Supplied by Name contact details of installer 13 0 SERVICE HISTORY Date of service Serviced by name Contact details of Engineer GAS SAFE No Date installed...

Страница 17: ...ide together with the registration number 3 Your appliance must have been serviced annually by Gas Safe registered installer evidence of which must be provided such as the receipt 4 Purchase s must be...

Отзывы: