The FoamPro MultiFlo Control Module and FoamPro

Digital Display Control Module are shown in Figure 1.

The FoamPro Multiflo allows a FoamPro system to

cover a wider flow range by allowing the proper size

flow sensor to be used for different discharges. For

example, a truck with one or more booster lines, 1

3

4

"

pre-connects, 2

1

2

" discharges and 3" deluge gun would

not be within the flow range of any one flow sensor.

(See flow ranges on the flowmeter drawing in Section

8). However, using a FoamPro Multiflo system will allow

a 1

1

2

" flow sensor to supply one or more booster lines,

a 2" flow sensor for the pre-connects, and 2

1

2

" and 3"

flow sensors for the other discharges. By combining

manifolds with multiple flowmeters, many discharges

may be accommodated over a wide flow range. It is

important to note that whether the piping is designed

using a mini manifold or a field fabricated manifold

system (see Figure 2), all discharges are supplied with

foam concentrate by a single foam injection point.

Figure 1. FoamPro MultiFlo Control Module and Digital Display Control Module

FoamPro MultiFlo Control Module

Digital Display Control Module

The FoamPro MultiFlo System is designed to monitor

up to four paddlewheel flowmeters and display the

individual flow rates of the foam discharge outlets. The

FoamPro MultiFlo control module transmits the total

flow of all operating discharges to the FoamPro System

which in turn displays the total flow value on the digital

control module display. For example, if Flow A is 200

GPM and Flow B is 300 GPM, the FoamPro Digital

Display Control Module will read 500 GPM.

Buttons are provided on the FoamPro MultiFlo control

module to allow the operator to read individual

discharge flow rates. By pressing a button, the flow for

that particular discharge outlet will be shown on the

FoamPro MultiFlo control module display. The rate

shown is the amount of water or foam solution flowing

through the flowmeter being monitored.

After calibration has been accomplished as described in

Section 4, the system is fully automatic and needs no

further adjustments.

2

Introduction

HYPRO

HYPRO

Содержание MultiFlo

Страница 1: ...ly inspected and tested In order to maintain the high quality of your unit and to keep it in a ready condition it is important to follow the instructions on care and operation Proper use and good prev...

Страница 2: ...OPERATION 13 6 DIAGNOSTIC PROCEDURES 14 7 PARTS IDENTIFICATION 15 8 INSTALLATION TEMPLATE 16 9 WARRANTY 20 NOTE TO SYSTEM INSTALLERS IMPORTANT Please provide a copy of the FoamPro manual to the end us...

Страница 3: ...it Improper handling and forcing connections can damage these cables which could result in other system damage 1 Always disconnect the power source before attempting to service any part of the FoamPro...

Страница 4: ...with foam concentrate by a single foam injection point Figure 1 FoamPro MultiFlo Control Module and Digital Display Control Module FoamPro MultiFlo Control Module Digital Display Control Module The F...

Страница 5: ...ortioner being used For example If the FoamPro 2001 foam proportioning system is used the maximum foam concentrate flow will be 2 6 GPM 9 8 LPM When the foam concentrate injection is set to 0 1 the am...

Страница 6: ...has five connectors on the back of the case see Figure 3 to connect the cables from the flowmeters and FoamPro Digital Display Control Module The FoamPro MultiFlo Control Module receives operating po...

Страница 7: ...lowmeter see Figure 5 10 times is even better the longer the straight run the lower the turbulence Here are some examples of required straight run Pipe Recommended Size Straight Run Pipe 11 2 38 mm 71...

Страница 8: ...mPro Digital Display Control Module Connect the cables from the flowmeter sensors to the connectors marked A B C or D on the back of the control module see Figure 3 If all connections are not used mak...

Страница 9: ...aking round coils see Figure 8 Install clamp on beads at the locations indicated in Figure 7 Use a small amount of RTV silicone electrical tape or heat shrink tubing to keep the beads from moving afte...

Страница 10: ...re 1 Remove the cover screw and the o ring to the left of the display readout panel on the MultiFlo Control 4 Calibration Procedures Module see Figure 9 Use a 3 32 allen wrench to remove the screw and...

Страница 11: ...e cover screw and o ring to keep water and dirt from entering the control module as it can cause serious damage to the components Flow Method of Calibration The flow method of calibration is being use...

Страница 12: ...dust from entering the control module 8 Proceed with the FoamPro foam proportioner system calibration per the applicable manual Total Volume Method of Calibration If a pitot gauge is not available th...

Страница 13: ...l match is when water or foam solution is flowing through one paddlewheel flowmeter equipped discharge The FoamPro MultiFlo Control Module constantly monitors the flow signals from the flowmeter senso...

Страница 14: ...control module display for any one of the paddlewheel flowmeters the flowmeter cable or flowmeter sensor could be defective and further diagnosis is required If no reading shows for any flowmeter the...

Страница 15: ...ng 3 2660 0030 11 2 NPT Paddle Wheel Flowmeter Assembly Note 1 Bore 2660 0031 11 2 NPT Paddle Wheel Flowmeter Assembly 2660 0032 2 NPT Paddle Wheel Flowmeter Assembly 2660 0033 21 2 NPT Paddle Wheel F...

Страница 16: ...ation and Operation Manual 8 4 25 2 75 4 25 78 3 50 3 70 10 24 x 44 DP 4 Holes Display requires a 3 875 inch 98mm diameter hole to be drilled in operator panel Additional space 3in 76mm required for c...

Страница 17: ...1 2 8 NPT 3 Pipe 5 3 8 137 mm 4 9 16 116 mm 20 750 8 900 2600 0033B 2 1 2 11 BSP 3 Pipe 5 3 8 137 mm 4 9 16 116 mm 20 750 8 900 2660 0034 3 8 NPT 4 Pipe 5 1 2 140 mm 4 7 8 124 mm 30 1150 12 1380 2600...

Страница 18: ...18 Installation and Operation Manual N O T E S...

Страница 19: ...19 Installation and Operation Manual MultiFlo N O T E S...

Страница 20: ...cts as above stated THERE ARE NO OTHER EXPRESS WARRANTIES ANY IMPLIED WARRANTIES INCLUDING IMPLIED WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO ONE YEA...

Отзывы: