![FoamPRO MultiFlo Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/foampro/multiflo/multiflo_installation-and-operation-manual_2313349013.webp)
13
Installation and Operation Manual
MultiFlo
will show a “?” symbol. This symbol will be seen as the
flow stops when the discharge valve is closed or when
very little water is flowing.
The combined total flow of all paddlewheel flowmeter
equipped discharge outlets that are connected is
totalized by the FoamPro MultiFlo Control Module, and
this total value is displayed on the FoamPro Digital
Display Control Module. The only time the two flow
readings will match is when water or foam solution is
flowing through one paddlewheel flowmeter equipped
discharge.
The FoamPro MultiFlo Control Module constantly
monitors the flow signals from the flowmeter sensors.
The pump operator monitors the flow reading of any one
of four paddlewheel flowmeter equipped discharges by
depressing the corresponding button on the FoamPro
MultiFlo Control Module. The system is automatic and
requires no adjustment after the initial installation
calibration.
The readout on the FoamPro MultiFlo display is
designed to read in whole flow units per minute. If less
than the minimum flow per minute is flowing, the display
5
Operation