background image

7

4.0

Structure appearance

1 Input monitoring port: USB-A, 9-PIN male;

2 Input monitoring port: TYPE-C, 24-PIN female socket;
3 input monitoring port: Micro-USB, 5-PIN female
socket; 4 output monitoring port: TYPE-C, 24-PIN
female socket; 5 PD communication switch
6 output monitoring port: USB-A, 9-PIN

female; 7 touch switch: BACK button;
8 Multi-function switches: left button, middle button, right

button; 9 PC connection port: Micro-USB, 5-PIN female socket.

.

Содержание FNB48

Страница 1: ...1 FNB48 User Manual V0 6...

Страница 2: ...charge trigger 5 3 0 5 Wire identification class 6 3 0 5 Miscellaneous 6 4 0 Structure appearance 7 5 0 Technical index 10 6 0 Main page 11 6 0 1 Concise page 11 6 0 2 Record page 12 6 0 7 Fast charge...

Страница 3: ...8 0 7 PD Protocol trigger 21 8 0 8 PD Protocol conversion 21 8 0 9 VOOC WARP Constant voltage trigger 22 8 0 9 SVOOC Trigger 22 9 0 Charging tool 23 9 0 1 PD Listener 23 9 0 2 Read E Marker cable 25 9...

Страница 4: ...l situations Please read the relevant content carefully and strictly abide by all warnings and precautions 2 0 Safety Precautions 1 Do not connect the monitoring interface to a power supply exceeding...

Страница 5: ...ch 3 Touch switch 3 0 3 Voltage and Current 1The highest six digit display of voltage current and power the highest resolution is 0 00001 V A W 2 Record the minimum maximum and average values of volta...

Страница 6: ...e trigger and automatically close the trigger when the time comes 3 0 5 Wire identification class 1 The internal resistance measurement of the wire by the differential pressure method 2 E Marker Cable...

Страница 7: ...3 input monitoring port Micro USB 5 PIN female socket 4 output monitoring port TYPE C 24 PIN female socket 5 PD communication switch 6 output monitoring port USB A 9 PIN female 7 touch switch BACK but...

Страница 8: ...wer 0 156W 0 00001W 0 5 2 Load equivalent internal resistance 0 9999 9 0 0001 0 5 2 D D voltage 0 3 3V 0 001V 1 0 2 Equipment temperature 1 1 2 3 1 1 2 4 Capacity 0 9999 99Ah 0 00001Ah Energy used 0 9...

Страница 9: ...alid 6 0 1 Concise page Description Only the three key parameters of voltage current and power are displayed indicates the direction of current This page can change the display direction Instructions...

Страница 10: ...re are two text boxes in the lower right corner the first 1 0 from top to bottom is the setting menu recording offline recording time in hours it is highlighted when recording otherwise it is grayed o...

Страница 11: ...cols stop triggering the charger will restart The dark blue below the trigger timing is the load resistance The first column of the bottom white table is D D voltage The second column is the current c...

Страница 12: ...e 3 Record offline curve Mode 4 High speed voltage ripple AC coupling Instructions 1 Long press the left button time base minus 2 Click the middle button start pause drawing the curve Except in mode 3...

Страница 13: ...age and current value as the reference value Measurement procedure 1 Connection mode charger FNB48 constant current load the current is adjusted to about 0 5 1A and record the reference value 2 Connec...

Страница 14: ...ameters from left to right are group number capacity energy the selected group is displayed in green and the lower left corner is the selected group Statistics time the lower right corner is the group...

Страница 15: ...eft right button Each item is explained below 1 Group is the statistical group selected for calculation This instrument can be selected from 1 10 groups statistical time capacity energy It is displaye...

Страница 16: ...CP SCP SamsungAFC trigger VOOC DASH constant pressure mode PD2 0 3 0 trigger and QC2 0 PD2 0 protocol conversion Note Once you enter the quick charge trigger detection interface All operations must be...

Страница 17: ...d continue testing During the test it is forbidden to connect to any equipment at the back end It does not respond to any key operation during the test If you want to exit during the test please unplu...

Страница 18: ...Click BACK to return Press the left right keys to quickly decrease increase the voltage 8 0 4 Huawei FCP trigger The operation method is the same as QC2 0 trigger 8 0 5 Huawei SCP trigger The operati...

Страница 19: ...re use Switch the PD communication switch to ON Then enter the PD protocol conversion mode after entering Plug in PD appliances You can perform PD fast charge In this mode Click the middle button and...

Страница 20: ...method is the same as QC3 0 trigger 8 0 9 SVOOC Trigger SuperVOOC requires a load greater than 500mA on the back end to deceive And SuperVOOC only has a voltage of 10 5V Therefore you can only press B...

Страница 21: ...ovide external power Use the PD listener function Need 2 C C cables Connect the charger and PD electrical appliances from the Type CIN interface and Type COUT interface respectively When the connectio...

Страница 22: ...for the gear required for charging for example it is 6 gears in this example request one of them indicates the direction of data transmission It means that this message was sent by the PD consumer to...

Страница 23: ...the Type C interface cannot be used for power supply PC port USB A Micro USB interface can all be used for power supply The PD communication switch needs to be turned ON After entering this function F...

Страница 24: ...uch thread in hand Only FNB48 tester and a C C cable But want to trigger VOOC WARP flash charge At this time the function of simulating DASH cable can be started And use the C C cable to connect to th...

Страница 25: ...the standby screen brightness Adjustable range 0 20 level when set to 0 Enter the standby state and turn off the screen directly 10 1 3 Standby time Set the standby time the last time you operate the...

Страница 26: ...settings except the recorded data 10 2 Settings menu Record Set the configuration required for logging data 10 2 1 Curve recording time Set the recording time of the voltage and current curve Maximum...

Страница 27: ...Off by default 10 4 Settings menu system You can view information such as the operating times of the instrument SN serial number and software version 11 0 Upgrade firmware instructions 1 Open the FNIR...

Отзывы: