important guarantee of lightning arresting and interference
rejection. Therefore, system must follow this rule:
1. Coaxial cable’s outer conductor and isolation layer should
keep sound electric conducting with the metal housing of device.
2. Grounding conductor must adopt copper conductor in order to
reduce high frequency impedance, and the grounding wire must
be as thick and short as possible.
3. The 2 terminals of grounding wire must make sure for well
electric conducting, and process for antirust.
4. It is prohibited that users use other devices as part of
grounding wire’s electric circuit
3.2.3.1 Frame Grounding
All the machine frames should connect to protective copper strip.
The grounding wire should be as short as possible and avoid
circling. The section of the conjunction between grounding wire
and grounding strip should be equal or greater than 25mm2.
3.2.3.2 Device Grounding
User can connect the device’s grounding rod to frame’s
grounding strip with copper wire.
3.2.4 Wires’ Connection
The power supply outlet is located at the right of rear panel, and
the power switch is just above it. The protective grounding wire