Operating Manual EMGZ 321
12.03.2020
24
Output Mode Selection
LCD:
Out1Mode
Use:
This parameter selects the output mode. The analogue output 1 can
be set to work as a voltage or as a current output.
Unit
Parameter Range
Selection
Default
Min
Max
- - -
0..10V
0..20mA
4..20mA
+/- 10V
+/-10V
Output Mode Selection
LCD:
Out2Mode
Use:
This parameter selects the output mode.
Unit
Parameter Range
Selection
Default
Min
Max
- - -
0..10V
+/- 10V
0..10V
Output Tension
LCD:
Out1 Ten
LCD:
Out2 Ten
Use:
This parameter determines the tension value at the maximum
output.
Unit
Parameter Range
Selection
Default
Min
Max
N
1)
0.1 100’000.0
-
1000.0
Filter
LCD:
Out1Filt
LCD:
Out2Filt
Use:
The amplifier provides an upstream low-pass filter to prevent noise
and interferences being overlaid to the output signal. This parameter
determines the cut off frequency of the filter. The lower the cut off
frequency, the more sluggish the output signal will be.
Unit
Parameter Range
Selection
Default
Min
Max
Hz 0.1 200.0
-
10