Parameter Setting over the Front Panel
7.1
Basic Instructions for Parameter Setting
The force amplifier EMGZ321 can be configured via its parameters. Moreover,
several adjustment procedures can be activated to capture or calculate application
relevant values. Parameters and all other settings are stored in the parameter list.
This list is organised in 4 parameter groups. In detail these are:
•
Amplifier Parameter Group
•
Outputs Parameter Group
•
Relay Outputs Parameter Group
•
System Parameter Group
The workflow in the Parametrisation State has three basic operator modi:
•
Parameter Group Selection
•
Parameter Selection within the group
•
Parameter Change or Setting
Parameter setting can be performed via the front panel or via a web browser.
The Parametrisation State can only be accessed from the “Operation State”. The
EMGZ321 displays only the parameters that are relevant for a used application (see
Fig. 8)
7.2
Amplifier Parameter Group
With the two procedures 6.3 “Offset Compensation” and 6.5 “Calibration Procedure”
the application specific parameter are determinate and the system calibrated.
These parameters are stored in the Amplifier Parameter Group.
7.3
Description of Amplifier Parameters
Offset A
Offset B
LCD:
Offset A
LCD:
Offset B
Use:
With the Offset Compensation procedure you can automatically
compensate the roller weight. It is always performed before the
calibration procedure. The value for offsetting the roller weight is stored
in the parameter
Offset
in
the parameter group Amplifier.
Unit
Parameter Range
Selection
Default
Min
Max
Digit -8000 +8000
-
0