![FMS EMGZ 490 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/fms/emgz-490/emgz-490_operating-manual_2313007020.webp)
Operation Manual EMGZ 490
15.12.2015
20
Index
Access Mode
1)
Parameter
Instruction
Data
Type
Range
Data Format
Uni
t
Description
0x2
3
R/
W
Scaling
Analogue
Output
unsigned
long
(unsigne
d 32 Bit)
0
to
200‘000‘000
#0.000 N
Determines
at
what force the
analogue output
outputs the its
maximal value
10V.
0x2
4
R/
W
Cut-off
frequency low
pass filter
feedback
(PROFINET)
unsigned
int
(unsigne
d 16 Bit)
1
to
2000
#0.0
Hz
Cut-off frequency
of PROFINET filter
0x2
5
R/
W
Cut-off
frequency low
pass filter
Analogue
output
unsigned
int
(unsigne
d 16 Bit)
1
to
2000
#0.0 Hz Cut-off
frequency
of analogue
output filter
0x3
0
W
Offset
compensation
-
-
-
-
Calculate offset
and store value
0x3
1
W Calibration signed
long
(signed
32 Bit)
±200‘000‘000 ±#0.00
0
N Calibrate
the
amplifier with
weight in N (must
correspond with
the used weight
for calibration).
1)
R = read, W = write, R/W = read and write.