 WARNING: These models have 

a three-prong, grounded electrical 

plug. This plug helps protect you 

against electrical shock. Only con

-

nect plug to a properly grounded, 

three-prong receptacle. Do not cut 

or remove the grounding prong 

from this plug.

 CAUTION: This fireplace cre

-

ates  warm  air  currents.  These 

currents move heat to wall sur-

faces next to fireplace. Installing 

fireplace next to vinyl or cloth 

wall  coverings  or  operating 

heater  where  impurities  (such 

as, but not limited, to tobacco 

smoke, aromatic candles, clean-

ing fluids, oil or kerosene lamps, 

etc.) in the air exist, may discolor 

walls or cause odors.

Note: Your fireplace is designed to be used in 

zero clearance installations. Wall or framing ma

-

terial can be placed directly against any exterior 

surface on the rear, sides or top of your fireplace, 

except where standoff spacers are integrally at

-

tached. If standoff spacers are attached to your 

fireplace, these spacers can be placed directly 

against wall or framing materials.

Use the dimensions shown for rough openings 

to create the easiest installation. See 

Built-In 

Fireplace Installation

, page 12.

IMPORTANT:

 Vent-free heaters add moisture 

to the air. Although this is beneficial, installing 

fireplace in rooms without enough ventilation 

air may cause mildew to form from too much 

moisture. See 

Air for Combustion and Ventila

-

tion

, page 6.

IMPORTANT:

 Make sure the fireplace is level. 

If fireplace is not level, log set will not work 

properly.

CHECK GAS TYPE

Use the correct gas type (natural or propane/

LP) for your fireplace. If your gas supply is not 

correct,  do  not  install  fireplace.  Call  dealer 

where you bought fireplace for proper type 

fireplace.

 WARNING: This appliance is 

equipped for either natural gas 

or propane/LP gas but not both. 

Gas type is indicated on the rat

-

ing plate. Field conversion is not 

permitted.

ELECTRICAL HOOKUP

This fireplace has a blower assembly with an 

electrical cord. The electrical cord is five feet 

in  length. You  must  locate  fireplace  within 

reach of 120-volt grounded electrical outlet. If 

not, you must install an electrical outlet within 

reach of fireplace power cord. The GA3555 

outlet accessory may be used for built-in 

installation when a blower is installed.

INSTALLING HOOD

Install hood to rail already installed in fireplace 

as shown in Figure 5. Use 3 Phillips screws 

provided.

INSTALLATION

Continued

Figure 5 - Installing Hood

Screw

Hood

Rail

ASSEMBLING AND ATTACHING 

OPTIONAL PERIMETER TRIM

 

(Included with Mantel Accessory)

IMPORTANT: 

If you are recessing the firebox 

in a wall, do not attach trim at this time. See 

Built-In Fireplace Installation

, page 12.

Note: 

These instructions are for assembling 

and attaching trim to fireplace.

1.  Remove packaging from three pieces 

of trim.

2.  Locate four screws, two adjusting plates 

with set screws, and two shims in the 

hardware packet.

3.  Align shim under adjusting plate as shown 

in Figure 6, page 10.

4.  Slide one end of adjusting plate/shim 

in slot on mitered edge of top trim (see 

Figure 6, page 10).

Содержание VSGF28NTF

Страница 1: ...Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas suppli...

Страница 2: ...xygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ven tilation section on page 6 of this manual This...

Страница 3: ...tions if you cannot reach your gas supplier call the fire department SAFETY Continued DANGER Carbon monoxide poisoning may lead to death Carbon Monoxide Poisoning Early signs of carbon monoxide poison...

Страница 4: ...all local codes In the absence of local codes use the latest edition of The National Fuel Gas Code ANSI Z223 1 NFPA 54 Available from American National Standards Institute Inc 1430 Broadway New York N...

Страница 5: ...safety information 1 With utility knife cut carton all the way around above staples on bottom tray Lift carton off of heater Remove packing Note Hood is located in packing on right hand side of heater...

Страница 6: ...entilation Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of un usually tight construction yo...

Страница 7: ...theInternationalFuelGasCode or applicable local codes 40 000 39 000 79 000 DETERMINING FRESH AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to...

Страница 8: ...not provide openings for inlet or outlet air into attic if attic has a thermo stat controlled power vent Heated air entering the attic will activate the power vent Figure 4 Ventilation Air from Outdo...

Страница 9: ...l If fireplace is not level log set will not work properly CHECK GAS TYPE Use the correct gas type natural or propane LP for your fireplace If your gas supply is not correct do not install fireplace C...

Страница 10: ...3 1 2 from the wall This com bustible material must be 4 from the side of the fireplace opening see Figure 8 B Clearances from the top of the fireplace opening to the ceiling should not be less than...

Страница 11: ...hammer or pliers 8 Place cardboard or other protective mate rial on top of hearth base Carefully set fireplace on protective material with back of fireplace inside mantel opening 9 If blower is insta...

Страница 12: ...ce to Wall Studs Nailing Flanges Nails or Wood Screws 3 Install gas piping into fireplace location This installation includes an approved flexible gas line if allowed by local codes after the equipmen...

Страница 13: ...CE Ifyourinstallationdoes not meet the minimum clear ances shown you must do one of the following raise the mantel to an accept able height remove the mantel NOTICE Surface temperatures of adjacent wa...

Страница 14: ...dealer Minimum inlet pressure for purpose of input adjustment Figure 18 Gas Connection Sediment Trap Equipment Shutoff Valve With 1 8 NPT Tap 3 Minimum Cap Pipe Tee Nipple Joint Natural Gas From Gas M...

Страница 15: ...replacing log base assembly Make sure the entire flexible gas line is in fireplace base area Reat tach log base assembly to fireplace with screws removed in step 2 WARNING Use pipe joint sealant that...

Страница 16: ...f gas supply piping sys tem Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak 5 Correct all leaks at once 6 Reconnect fireplace and equipment shutoff valve to gas suppl...

Страница 17: ...or failure to use only parts specifically approved with this heater may result in property damage or personal injury CAUTION Do not remove the data plates attached to the heater base assembly The data...

Страница 18: ...gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or...

Страница 19: ...s Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information page 18 If you don t smell gas go to the next step 5 Turn control knob counterclockwise to the PI...

Страница 20: ...your fireplace could pro duce increased levels of carbon monoxide Followinstructionsat bottomofthispage Yellowflame on rear burner is normal NOTICE Do not mistake orange flames with yellow tipping Di...

Страница 21: ...r store hardware store or home center may carry compressed air in a can If using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could dam...

Страница 22: ...ure Manifold 3 4 W C Inlet Gas Pressure in of water Maximum 10 5 W C Minimum 5 W C Shipping Weight 100 lbs For input adjustment Model VSGF28PTF Rating Variable 23 000 28 000 Btu Hr Type Gas Propane LP...

Страница 23: ...ocated behind base panel 4 Replace ignitor cable 5 Replace piezo ignitor 6 Replace pilot assembly 7 Replace pilot assembly 1 Turn on gas supply or open equipment shutoff valve 2 Turn control knob to P...

Страница 24: ...30 seconds 3 Fully open equipment shut off valve 4 A Contact local natural or propane LP gas company B Clean ODS pilot see Cleaning page 21 or re place ODS pilot assembly 5 Hand tighten until snug th...

Страница 25: ...gas line checked by local natural or propane LP gas company 3 Observe minimum instal lation clearances see page 10 4 Clean burners see Clean ing page 21 or replace burner orifice s 1 Turn heater off...

Страница 26: ...Clean ing page 21 1 Locate and correct all leaks see Checking Gas Con nections page 16 2 Replace control valve or gas control 1 Take apart gas tubing and remove foreign matter 2 Locate and correct al...

Страница 27: ...ss listed on the back page of this manual FIREBOX BRICK LINER HFL300 Stacked Brick Pattern AgedAlmond HFL301 Stacked Brick Pattern Aged Red HFL310 Herringbone Brick Pattern Aged Almond HFL311 Herringb...

Страница 28: ...www fmiproducts com 119303 01G 28 11 13 23 17 9 4 6 10 18 7 8 27 1a 1b 1f 1c 1d 1e 15 3 2 19 22 20 16 21 12 12 24 18 25 14 26 5 PARTS MODELS VSGF28NTF AND VSGF28PTF...

Страница 29: ...1 10 098271 10 Ignitor Cable 1 11 Firebox Bottom 1 12 098867 10 Gas Regulator 1 098867 09 Gas Regulator 1 13 101004 01 Front Burner Injector 1 101004 04 Front Burner Injector 1 14 102845 01 Inlet Tub...

Страница 30: ...www fmiproducts com 119303 01G 30 PARTS MODELS VSGF28NTF AND VSGF28PTF 1 2 3 4 16 16 6 12 18 10 10 7 13 16 26 24 16 23 25 20 24 24 21 16 16 27 17 14 5 16 16 15 8 9 19 22 11 11 11...

Страница 31: ...ox Support 2 11 099230 01 Shoulder Screw 4 12 101872 03 Firebox Top 1 13 101346 01 Outer Base 1 14 Firebox Wrapper 1 15 101614 02 Limit Switch Thermal Disk Assembly 1 16 M11084 26 Hex Screw 10 57 17 0...

Страница 32: ...s product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic ma...