background image

www.fmiproducts.com

119303-01G

15

INSTALLATION

Continued

Figure 19 - Removing Log Base 

Assembly From Fireplace 

Figure 20 - Attaching Flexible Gas Lines 

Flexible Gas Line 

from Fireplace 

Gas Regulator

To Fireplace 

Gas Regulator

Equipment 

Shutoff Valve 

Provided by 

Installer

Propane/LP

To External 

Regulator

Natural Gas

To Gas Meter

  CAUTION:  Do  not  pick  up 

log  base  assembly  by  burner. 

This could damage burner. Only 

handle base by grates.

3.  Route gas line (provided by installer) 

from equipment shutoff valve to fireplace. 

Route flexible gas supply line through one 

of the access holes.

NOTICE:  Most  building  codes 

do  not  permit  concealed  gas 

connections. A flexible gas line 

is provided to allow accessibility 

from the fireplace (see Figure 20). 

The flexible gas supply line con

-

nection to the equipment shutoff 

valve should be accessible.

4.  Attach the flexible gas line to gas supply 

(see Figure 20). Check tightness of flex

-

ible gas line attached to gas regulator of 

fireplace (see Figure 20).

5.  Check all gas connections for leaks. See 

Checking Gas Connections, 

page 16.

6.  Replace log base assembly back into 

fireplace. Feed flexible gas line into fire

-

place base area while replacing log base 

assembly.  Make  sure  the  entire  flexible 

gas line is in fireplace base area. Reat

-

tach log base assembly to fireplace with 

screws removed in step 2.

  WARNING:  Use  pipe  joint 

sealant that is resistant to liquid 

petroleum (LP) gas.

We recommend that you install a sediment 

trap in supply line as shown in Figure 18. 

Locate sediment trap where it is within reach 

for cleaning. Install in piping system between 

fuel  supply  and  fireplace.  Locate  sediment 

trap where trapped matter is not likely to 

freeze. A sediment trap traps moisture and 

contaminants. This keeps them from going 

into fireplace gas controls. If sediment trap 

is not installed or is installed wrong, fireplace 

may not run properly.

CONNECTING FIREPLACE TO GAS 

SUPPLY

Installation Items Needed

•  5/16" hex socket wrench or nut-driver
•  Phillips screwdriver 
•  sealant (resistant to propane/LP gas, not 

provided)

1.  Remove  fireplace  screen.  Remove  one 

screw that holds fireplace screen in place 

for shipping. This screw is located near top 

left side of screen. Discard screw. Lift fire

-

place screen up and pull out to remove.

2.  Remove screws that attach log base 

assembly  to  fireplace  (see  Figure  19). 

Carefully lift up log base assembly and 

remove from fireplace (see Figure 19).

Note: If adding the HFL series brick liner ac

-

cessory, install it now. Follow instructions in 

HFL series accessory kit.

Содержание VSGF28NTF

Страница 1: ...Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas suppli...

Страница 2: ...xygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ven tilation section on page 6 of this manual This...

Страница 3: ...tions if you cannot reach your gas supplier call the fire department SAFETY Continued DANGER Carbon monoxide poisoning may lead to death Carbon Monoxide Poisoning Early signs of carbon monoxide poison...

Страница 4: ...all local codes In the absence of local codes use the latest edition of The National Fuel Gas Code ANSI Z223 1 NFPA 54 Available from American National Standards Institute Inc 1430 Broadway New York N...

Страница 5: ...safety information 1 With utility knife cut carton all the way around above staples on bottom tray Lift carton off of heater Remove packing Note Hood is located in packing on right hand side of heater...

Страница 6: ...entilation Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of un usually tight construction yo...

Страница 7: ...theInternationalFuelGasCode or applicable local codes 40 000 39 000 79 000 DETERMINING FRESH AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to...

Страница 8: ...not provide openings for inlet or outlet air into attic if attic has a thermo stat controlled power vent Heated air entering the attic will activate the power vent Figure 4 Ventilation Air from Outdo...

Страница 9: ...l If fireplace is not level log set will not work properly CHECK GAS TYPE Use the correct gas type natural or propane LP for your fireplace If your gas supply is not correct do not install fireplace C...

Страница 10: ...3 1 2 from the wall This com bustible material must be 4 from the side of the fireplace opening see Figure 8 B Clearances from the top of the fireplace opening to the ceiling should not be less than...

Страница 11: ...hammer or pliers 8 Place cardboard or other protective mate rial on top of hearth base Carefully set fireplace on protective material with back of fireplace inside mantel opening 9 If blower is insta...

Страница 12: ...ce to Wall Studs Nailing Flanges Nails or Wood Screws 3 Install gas piping into fireplace location This installation includes an approved flexible gas line if allowed by local codes after the equipmen...

Страница 13: ...CE Ifyourinstallationdoes not meet the minimum clear ances shown you must do one of the following raise the mantel to an accept able height remove the mantel NOTICE Surface temperatures of adjacent wa...

Страница 14: ...dealer Minimum inlet pressure for purpose of input adjustment Figure 18 Gas Connection Sediment Trap Equipment Shutoff Valve With 1 8 NPT Tap 3 Minimum Cap Pipe Tee Nipple Joint Natural Gas From Gas M...

Страница 15: ...replacing log base assembly Make sure the entire flexible gas line is in fireplace base area Reat tach log base assembly to fireplace with screws removed in step 2 WARNING Use pipe joint sealant that...

Страница 16: ...f gas supply piping sys tem Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak 5 Correct all leaks at once 6 Reconnect fireplace and equipment shutoff valve to gas suppl...

Страница 17: ...or failure to use only parts specifically approved with this heater may result in property damage or personal injury CAUTION Do not remove the data plates attached to the heater base assembly The data...

Страница 18: ...gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or...

Страница 19: ...s Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information page 18 If you don t smell gas go to the next step 5 Turn control knob counterclockwise to the PI...

Страница 20: ...your fireplace could pro duce increased levels of carbon monoxide Followinstructionsat bottomofthispage Yellowflame on rear burner is normal NOTICE Do not mistake orange flames with yellow tipping Di...

Страница 21: ...r store hardware store or home center may carry compressed air in a can If using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could dam...

Страница 22: ...ure Manifold 3 4 W C Inlet Gas Pressure in of water Maximum 10 5 W C Minimum 5 W C Shipping Weight 100 lbs For input adjustment Model VSGF28PTF Rating Variable 23 000 28 000 Btu Hr Type Gas Propane LP...

Страница 23: ...ocated behind base panel 4 Replace ignitor cable 5 Replace piezo ignitor 6 Replace pilot assembly 7 Replace pilot assembly 1 Turn on gas supply or open equipment shutoff valve 2 Turn control knob to P...

Страница 24: ...30 seconds 3 Fully open equipment shut off valve 4 A Contact local natural or propane LP gas company B Clean ODS pilot see Cleaning page 21 or re place ODS pilot assembly 5 Hand tighten until snug th...

Страница 25: ...gas line checked by local natural or propane LP gas company 3 Observe minimum instal lation clearances see page 10 4 Clean burners see Clean ing page 21 or replace burner orifice s 1 Turn heater off...

Страница 26: ...Clean ing page 21 1 Locate and correct all leaks see Checking Gas Con nections page 16 2 Replace control valve or gas control 1 Take apart gas tubing and remove foreign matter 2 Locate and correct al...

Страница 27: ...ss listed on the back page of this manual FIREBOX BRICK LINER HFL300 Stacked Brick Pattern AgedAlmond HFL301 Stacked Brick Pattern Aged Red HFL310 Herringbone Brick Pattern Aged Almond HFL311 Herringb...

Страница 28: ...www fmiproducts com 119303 01G 28 11 13 23 17 9 4 6 10 18 7 8 27 1a 1b 1f 1c 1d 1e 15 3 2 19 22 20 16 21 12 12 24 18 25 14 26 5 PARTS MODELS VSGF28NTF AND VSGF28PTF...

Страница 29: ...1 10 098271 10 Ignitor Cable 1 11 Firebox Bottom 1 12 098867 10 Gas Regulator 1 098867 09 Gas Regulator 1 13 101004 01 Front Burner Injector 1 101004 04 Front Burner Injector 1 14 102845 01 Inlet Tub...

Страница 30: ...www fmiproducts com 119303 01G 30 PARTS MODELS VSGF28NTF AND VSGF28PTF 1 2 3 4 16 16 6 12 18 10 10 7 13 16 26 24 16 23 25 20 24 24 21 16 16 27 17 14 5 16 16 15 8 9 19 22 11 11 11...

Страница 31: ...ox Support 2 11 099230 01 Shoulder Screw 4 12 101872 03 Firebox Top 1 13 101346 01 Outer Base 1 14 Firebox Wrapper 1 15 101614 02 Limit Switch Thermal Disk Assembly 1 16 M11084 26 Hex Screw 10 57 17 0...

Страница 32: ...s product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic ma...

Отзывы: