background image

www.fmiproducts.com

55173H

10

To install:
1.  Remove gas line cover plate from appliance’s 

outer surround at the location to be used.

2.  Remove insulation from inside the gas line 

conduit sleeve.

3.  Run gas line through sleeve.
4.  Prepare  incoming  black  iron  gas  line  with 

Teflon tape or pipe joint compound. (Check 

local codes as to the use of Teflon tape.)

 CAUTION: Compounds used 

on threaded joints of gas piping 

shall be resistant to the action 

of  Liquefied  Petroleum  (LP  or 

propane) and should be applied 

lightly to ensure excess sealant 

does not enter the gas line.

5.  Connect incoming gas line to regulator. Secure 

all joints tightly with wrench, but do not over 

tighten. If a flexible gas line is used, take care 

not to kink the connector.

6.  Re-pack insulation in and around the conduit 

sleeve and flexible gas line.

  WARNING:  All  gas  piping 

and connections must be tested 

for leaks after the installation is 

completed.

After ensuring that the gas valve 

is on, apply a commercial leak 

detection  solution  to  all  con-

nections and joints. If bubbles 

appear,  leaks  can  be  detected 

and corrected.

Do not use an open flame for leak 

testing and do not operate any 

appliance if a leak is detected.

Typical Exterior Wall Gas 

Shutoff Installation

Key

Extension

Shutoff 

Valve

FIREPLACE 

INSTALLATION

Continued

Figure 15 - Typical Exterior Wall Gas 

Shut-Off Installation

LOG SET PLACEMENT

Carefully remove log set from packaging. Place 

the two bottom logs over grate and align with pins. 

Place three loose logs, or twigs, onto alignment 

pins on two bottom logs (see Figure 16).

Figure 16 - Log Placement

FIREPLACE FACING

Any non-combustible material may be used for 

facing (glass, tile, brick, etc.) as long as the proper 

clearances are adhered to and the fireplace open-

ings are not blocked or obstructed in any way. See 

Clearances

, page 6, and Figure 17 on page 11.

Use only heat-resistant, noncombustible mortar 

or adhesive when securing facing material to the 

front of the fireplace.

Bottom Logs

Top Logs (Twigs)

Содержание (V)GL36ST

Страница 1: ...light any appliance Do not touch any electrical switch Do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier INSTALLER Leave this manual with the appliance CO...

Страница 2: ...ow to install and maintain your appliance it also con tains information that will enable you to obtain replace ment parts or optional accessory items when needed Keep it with your other important papers This appliance is only for use with the type of gas indi cated on the rating plate This appliance is not convertible for use with other gases TABLE OF CONTENTS Safety Information 3 Dimensions 4 Int...

Страница 3: ...ly for use with the type of gas indicated on the rating plate This ap pliance is not convertible for use with other gases 2 For propane LPfireplace donotplacepropane LP supply tank s inside any structure Locate propane LPsupplytank s outdoors Toprevent performance problems do not use propane LP fuel tank of less than 100 lbs capacity 3 If you smell gas shut off gas supply do not try to light any a...

Страница 4: ...ith adequate accessibility clearance for servicing and proper operation Safety information Continued 16 Do not install fireplace directly on carpeting vinyl tile or any combustible material other than wood The fireplace must set on a metal or wood panel extending the full width and depth of the fireplace 17 Do not use fireplace if any part has been ex posed to or under water Immediately call a qua...

Страница 5: ...CTS LLC in combination with this appliance C Installation and or operation in a manner other than instructed in this manual D The burning of anything other than the type of gas approved for use in this gas appliance This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 Theinstallati...

Страница 6: ...be observed 1 Do not connect this appliance to a chimney system used for a solid fuel burning fire place 2 Install in an area providing ventilation and adequate combustion air 3 Due to high temperatures do not locate this appliance in high traffic areas or near furniture and draperies 4 Never obstruct the front opening of the appli ance or the flow of combustion and ventilation air Keep control co...

Страница 7: ...le Material Other Than Wood 52 3 4 1340 mm Min 46 11688 mm 22 3 4 578 mm vent pipe installation A6 B 1 type gas vent pipe is a double wall vent ing system not supplied which must be installed during rough framing of the appliance Any B 1 type gas vent system may be used for proper vent ing as long as the vent system is installed per the vent manufacturer s recommendations FMIPRODUCTS LLCsupplies t...

Страница 8: ...d repair Wall Switch Installation 1 Remove the J box cover plate from side of appliance s outer surround 2 Using the 18 ga millivolt wire and wall switch both supplied connect wiring per wiring diagram see Figure 11 For more detail see Wiring Diagrams on page 16 Note If any of the original 10 feet supplied wire must be replaced use Thermostat Millivolt Wire 18 AWG Type CL2 105 C or equivalent only...

Страница 9: ...d to the unit when field converting See Specifications page 15 when derating The gas control valve is secured to the burner pan assembly underneath the front ledge A 1 8 NPT plugged tapping is provided on the gas control valve for a test gauge connection immediately upstream of the gas supply connection to the ap pliance see Figures 13 and 14 Figure 12 Wiring Through Outer Surround Figure 13 Milli...

Страница 10: ...e installation is completed Afterensuringthatthegasvalve is on apply a commercial leak detection solution to all con nections and joints If bubbles appear leaks can be detected and corrected Donotuseanopenflameforleak testing and do not operate any appliance if a leak is detected Typical Exterior Wall Gas Shutoff Installation Key Extension Shutoff Valve Fireplace Installation Continued Figure 15 T...

Страница 11: ... Facing Material Figure 18 Correct Pilot Flame Pattern Millivolt Assembly Figure 19 Correct Pilot Flame Pattern Electronic Assembly Burner Flame Adjustment The air shutter located at the base of the main burner tube has been factory preset to the proper air to bas ratio which results in a long blue cleaner burning flame see Figure 20 If readjustment is necessary loosen the air shut ter screw and r...

Страница 12: ...FT your left as you face the fireplace moves glass door s top inner corner UP moving spring clip to the RIGHT moves glass door s top inner corner DOWN c When door alignment is satisfactory use Phillips screwdriver to retighten spring clip screw WARNING When fireplace is in operation both sets of cabinetdoorsoneachsideofthe fireplace must be either FULLY OPEN or FULLY CLOSED If not a fire hazard ma...

Страница 13: ...r burning logs will give off a paper burning smell Orange flame will also be pres ent Open window to vent smell This will only last a few hours 1 STOP Read the safety information column 1 2 Turn wall switch to the OFF position 3 Turn off all electric power to the appliance 4 Open control access panel 5 Push in gas control knob and turn clock wise to the OFF position see Figure 23 Note It is recomm...

Страница 14: ... turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service tech nician or gas supplier Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control sys...

Страница 15: ... logs clean by vacuuming or brushing at least twice a year Take care not to alter the set tings on the pilot assembly Do not use abrasive liquids or cleaners for cleaning glass doors and trims Any household glass cleaner should suffice Do not clean doors when hot Allow appliance to cool before cleaning Technical Service You may have further questions about installation operation or troubleshooting...

Страница 16: ...SUPPLY millivolt wiring diagram STEP DOWN TRANSFORMER EV2 SUPPLY INCOMING MAIN GAS EV1 TO GAS LINE BURNER 24V AC N C SW HEAT LIMIT SWITCH 120V AC 120V AC INCOMING OR BREAKER FUSE BOX OFF ON SUPPLIED WALL SWITCH GREEN BLACK WHITE 120v 60Hz 0 7A ELECTRICAL RATING BLACK WHITE GREEN OPTIONAL REMOTE CONTROL SENSOR PILOT IGNITOR PV GND PV MV TR MV TH IGN Electronic wiring diagram Wiring Diagrams ...

Страница 17: ...fective control valve 1 Wall switch wires defective 2 Thermopile or sensor not generating sufficient voltage 1 Pilot flame may be too low causing safety pilot to drop out 1 Millivolt output on thermo pile too high REMEDY 1 Check to see if you have gas supply 2 Hold regulator control valve in the PILOT position for 2 to 3 minutes to purge air If you smell gas stop and wait for a few minutes before ...

Страница 18: ... current is being sent back to regulator 2 If valve knob and wall switch are in the ON position prob able defective control valve 1 Wall switch wires defective 2 Thermocouple generator or sensor not generating suf ficient voltage 1 Pilot flame may be too low causing safety pilot to drop out 1 Output on flame sensor too high REMEDY 1 Check to see if you have gas supply 2 Remove debris and dirt in s...

Страница 19: ...all models orifice Natural Gas 23105 Propane LP Gas 23106 For use with all models Wall Switch Kit 22180 Wall Switch 14112 Cover Plate 14113 For use with all models Ignition Control 110286 01 For use with all models Gas Valve Conversion Kit Millivolt Propane LP Gas PC GL36 Millivolt Natural Gas NC GL36 Electronic Propane LP Gas PC GL36E Electronic Natural Gas NC GL36E Burner Assembly 23439 For use ...

Страница 20: ...product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic material labor and incidental costs associated with warranty repairs unless expressly covered by this warranty are not reimbursable under this warranty and are the responsibility of the owner Excluded fro...