CLEANING AND
MAINTENANCE
WARNING: Installation and
repair should be done by a
qualified service person. The
appliance should be inspected
before each use and at least
annually by a qualified service
person. More frequent clean-
ing may be required due to
excessive lint from carpeting,
bedding material, pet hair, etc.
It is imperative that the control
compartments, burners and
circulating air system be kept
clean.
WARNING: The logs can be
hot. Handle only when cool.
TO TURN OFF GAS
TO APPLIANCE
1. Turn off all electric power to the appliance
if service is to be performed.
2. Remove control access panel.
3. Close the gas valve.
OPERATING FIREPLACE
Continued
Figure 26 - Pilot
WARNING: Turn off gas and
electrical power before servicing
appliance. Any safety screen
or guard removed for servicing
must be replaced prior to operat
-
ing the appliance.
WARNING: Failure to keep
the primary air opening(s) of
the burner(s) clean may result in
sooting and property damage.
Keep control compartment, logs, burner and area
surrounding logs clean by vacuuming or brushing
at least twice a year. Take care not to alter the set-
tings on the pilot assembly.
Do not use abrasive liquids or cleaners for cleaning
glass doors and trims. Any household glass cleaner
should suffice. Do not clean doors when hot. Allow
appliance to cool before cleaning.
TECHNICAL SERVICE
You may have further questions about installation,
operation or troubleshooting. If so, contact FMI
PRODUCTS, LLC’s Technical Service Depart-
ment at 1-866-328-4537. When calling please
have your model and serial numbers of your
heater ready.
You can also visit our web site at
www.fmiproducts.com
.
SPECIFICATIONS
(V)GL36ST, (V)GL36STE
• Maximum Input Rating at Altitudes: 2,000 ft.
- 42,000 Btu/hr., 2,000 ft. to 4,000 ft. - 37,800
Btu/hr.
• Manifold Pressure: 3.5 W.C. (.87 kPa)
• Supply Pressure (in. of water): Minimum* - 4.5"
(1.12 kPa), Maximum - 11.0" (2.74 kPa)
• Orifice Size at Altitudes: 2,000 ft. - #30, 2,000 ft.
to 4,000 ft. - #31
(V)GL36STP, (V)GL36STEP
• Maximum Input Rating at Altitudes: 2,000 ft.
- 42,000 Btu/hr., 2,000 ft. to 4,000 ft. - 37,800
Btu/hr.
• Manifold Pressure: 11.0 W.C. (2.74 kPa)
• Supply Pressure (in. of water): Minimum* -
12.0" (2.89 kPa), Maximum - 13.0" (3.23 kPa)
• Orifice Size at Altitudes: 2,000 ft. - #49, 2,000 ft.
to 4,000 ft. - #51
* For the purpose of input adjustment