TO TURN OFF GAS 

TO APPLIANCE

1.  Turn off the wall switch.
2.  Turn off all electric power to the appliance 

if service is to be performed.

3.  Remove control access panel.
4.  Push in gas control knob and turn clockwise 

 to OFF. Do not force.

5.  Close shutoff valve (see Figure 14, page 9).
6.  Replace control access panel.

ELECTRONIC MODELS

FOR YOUR SAFETY 

READ BEFORE LIGHTING

 WARNING: If you do not fol-

low these instructions exactly, 

a  fire  or  explosion  may  result 

causing property damage, per

-

sonal injury or loss of life.

A.  This appliance is equipped with an ignition 

device which automatically lights the pilot. 

Do not light the pilot by hand.

B.  BEFORE LIGHTING smell all around the 

appliance area for gas. Be sure to smell next 

to the floor because some gas is heavier than 

air and will settle on the floor.

 

WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.

•  Do not touch any electric switch; do not 

use any phone in your building.

•  Immediately call your gas supplier from 

a neighbor’s phone. Follow the gas sup-

plier’s instructions.

•  If you cannot reach your gas supplier, 

call the fire department.

C.  Use only your hand to push in or turn the 

gas control knob. Never use tools. If the 

knob will not push in or turn by hand, don’t 

try to repair it, call a qualified service tech-

nician or gas supplier. Force or attempted 

repair may result in a fire or explosion.

D.  Do not use this appliance if any part has 

been  under  water.  Immediately  call  a 

qualified service technician to inspect the 

appliance and to replace any part of the 

control system and any gas control which 

has been under water.

OPERATING FIREPLACE

Continued

LIGHTING 

INSTRUCTIONS

NOTICE: During initial operation 

of new heater, burning logs will 

give off a paper-burning smell. 

Orange flame will also be pres

-

ent. Open window to vent smell. 

This will only last a few hours.

1.  STOP!  Read  the  safety  information, 

column 1.

2.  Set the thermostat to lowest setting (if 

applicable).

3.  Turn off wall switch.
4.  Open control access panel or louver.
5.  Smell for gas, including near the floor. If you 

smell gas, STOP! Follow “B” in the safety 

information in column 1. If you don’t smell 

gas, go to the next step.

6.  Turn the main burner wall switch to the ON 

position for ignition. There will be a spark 

at the electrode. The electrode is located by 

main burner (see Figure 21).

7.  Replace control access panel or louver once 

there is a flame at the burner.

8.  If burner will not stay lit after several tries, 

flip the wall switch to OFF and call your 

service technician or gas supplier.

Figure 22 - Electronic Control Valve

E

A

From 

Gas 

Supply

To 

Main 

Burner

Inlet Pressure Outlet Pressure

Figure 21 - Pilot

TO TURN OFF GAS 

TO APPLIANCE

1.  Turn off all electric power to the appliance 

if service is to be performed.

2.  Remove control access panel.
3.  Close shutoff valve (see Figure 14, page 9).

Содержание (V)gl36cl(e)

Страница 1: ...ighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference WARNING If the information in these instructions is not followed exactly a fire or ...

Страница 2: ...lified installer service agency or the gas supplier NOT FOR USE WITH SOLID FUEL CHECK LOCAL CODES PRIOR TO INSTALLATION SAVE THIS BOOK This book is valuable In addition to instructing you on how to install and maintain your appliance it also con tains information that will enable you to obtain replace ment parts or optional accessory items when needed Keep it with your other important papers This ...

Страница 3: ...nly for use with the type of gas indicated on the rating plate This ap pliance is not convertible for use with other gases 2 For propane LPfireplace donotplacepropane LP supply tank s inside any structure Locate propane LPsupplytank s outdoors Toprevent performance problems do not use propane LP fuel tank of less than 100 lbs capacity 3 If you smell gas shut off gas supply do not try to light any ...

Страница 4: ...esaroundairopeningsintothecombus tion chamber along with adequate accessibility clearance for servicing and proper operation Safety information Continued 16 Do not install fireplace directly on carpeting vinyl tile or any combustible material other than wood The fireplace must set on a metal or wood panel extending the full width and depth of the fireplace 17 Do not use fireplace if any part has b...

Страница 5: ... PRODUCTS LLC in combination with this appliance C Installation and or operation in a manner other than instructed in this manual D The burning of anything other than the type of gas approved for use in this gas appliance This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 Theinst...

Страница 6: ...d 1 Do not connect this appliance to a chimney system used for a solid fuel burning fire place 2 Install in an area providing ventilation and adequate combustion air 3 Due to high temperatures do not locate this appliance in high traffic areas or near furniture and draperies 4 Never obstruct the front opening of the appli ance or the flow of combustion and ventilation air Keep control compartments...

Страница 7: ...tallation A6 B 1 type gas vent pipe is a double wall vent ing system not supplied which must be installed during rough framing of the appliance Any B 1 type gas vent system may be used for proper vent ing as long as the vent system is installed per the vent manufacturer s recommendations FMI PRODUCTS LLC supplies this appliance with a tapered starter pipe for a snug fit Slide B 1 type vent pipe ov...

Страница 8: ...s are supplied with a wall switch kit for ready connection and mounting CAUTION Do not connect the remote wall switch to a regular 120v power source Gas valve will be damaged beyond repair Connect 18 ga wires from wall switch to gas control valve terminals marked TH and TPTH or to ignition module using pigtails and wire nut connectors supplied with appliance Note If any of the original supplied wi...

Страница 9: ...n extra gas shutoff valve outside the ap pliance s enclosure check with local codes where it can be accessed more conveniently with a key through a wall as shown in Figure 14 Route a 1 2 NPT gas line towards appliance coming in from back of appliance If installation permits you may alternately route your incoming gas line from bottom of appliance toward either end It is recommended to route gas pi...

Страница 10: ... twigs onto alignment pins on two bottom logs see Figure 16 Fireplace Installation Continued Fireplace Facing Any noncombustible material may be used for facing glass tile brick etc as long as the proper clearances are adhered to and the fireplace open ings are not blocked or obstructed in any way See Clearances page 6 and Figure 17 Use only heat resistant noncombustible mortar or adhesive when se...

Страница 11: ...NS 1 STOP Read the safety information above 2 Turn wall switch to the OFF position 3 Turn off all electric power to the appliance 4 Open control access panel 5 Push in gas control knob and turn clock wise to the OFF position see Figure 19 Note It is recommended that you maintain the gas control knob in the full OFF position during lengthy periods of seasonal non usage 6 Wait five 5 minutes to clea...

Страница 12: ...s supplier Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water OPERATING FIREPLACE Continued LIGHTING INSTRUCTIONS NOTICE Duringinitialoperation of new heater burnin...

Страница 13: ...sary and should be done by a qualified technician The pilot assembly is located behind the burner next to the rear refractory piece at the right hand side The thermopile in millivolt models or the sensor in electronic models should be engulfed with the pilot flame approximately 3 8 to 1 2 in order for the regulator to receive proper signal see Figures 23 and 24 Burner Flame Adjustment The air shut...

Страница 14: ...and electrical power before servic ingappliance Anysafetyscreen or guard removed for servicing must be replaced prior to oper ating the appliance WARNING Make certain that wires and gas lines are not touching underside of firebox WARNING Do not abuse strike or slam glass doors WARNING Do not operate appliance with panel s and glass removed cracked or bro ken Replacement of panel s shouldbedonebyal...

Страница 15: ...ifice Size at Altitudes 0 2 000 ft 49 2 000 4 000 ft 51 For the purpose of input adjustment DO NOT CONNECT N C SW HEAT LIMIT SWITCH TH TP TP TH WALL SWITCH SUPPLIED TO 120V THERMOPILE PILOT IGNITOR O FF P I L O T ON PILOT SAFETY WIRE MAIN GAS INCOMING SUPPLY millivolt wiring diagram Electronic wiring diagram Wiring Diagrams STEP DOWN TRANSFORMER EV2 SUPPLY INCOMING MAIN GAS EV1 TO GAS LINE BURNER ...

Страница 16: ...ow causing safety pilot to drop out 1 Millivolt output on thermo pile too high 1 Defective ignitor no spark at electrode 2 Defective pilot or misaligned electrode at pilot spark at electrode 3 Low line pressure 4 No propane LP gas in tank Propane LP units only REMEDY 1 Check to see if you have gas supply 2 Hold regulator control valve in PILOTpositionfor2 3minutes to purge air If you smell gas sto...

Страница 17: ... Main burner flame too low 4 Bad ignition assembly 1 Wall switch wires defective 1 Burner flame is too low or ignitor is misaligned casing safety main burner to drop out REMEDY 1 Check to see if you have gas supply 2 Repeat lighting procedure until air is removed If after repeated attempts fireplace does not light call a qualified service and repair technician 3 Remove debris and dirt in spect and...

Страница 18: ... For use with all models orifice Natural Gas 23105 Propane LP Gas 23106 For use with all models Wall Switch Kit GWMS2 For use with all models Ignition Control 110286 01 For use with all models Gas Valve Conversion Kit Millivolt Propane LP Gas PC GL36 Millivolt Natural Gas NC GL36 Electronic Propane LP Gas PC GL36E Electronic Natural Gas NC GL36E Cabinet Style Door Kit Brushed Brass DBBGL36C Platin...

Страница 19: ..._____________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________...

Страница 20: ...s product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic material labor and incidental costs associated with warranty repairs unless expressly covered by this warranty are not reimbursable under this warranty and are the responsibility of the owner Excluded f...