background image

www.fmiproducts.com

55511F

12

Figure 28 - Gas Line Knockout

Side 
Firebrick 
Finished 
Side

Refractory 
Knockout 
Plug

Outside of 
Fireplace

Gas Line 
Conduit
Insulation

Gas 
Conduit 
Cover

1/2" Dowel

Remove 
Knockout

:$51,1*$TXDOL¿HGVHU

-

vice person must connect gas 

VXSSO\)ROORZDOOORFDOFRGH

s.

NOTICE: 

Before you proceed, make sure your 

gas supply is turned off.
A gas line may be installed for the purpose 
of installing a vented or vent-free decorative 
gas  appliance  available  through  your  local 
distributor. Use only 1/2" black iron pipe and 

DSSURSULDWH ¿WWLQJV :KHQ LQVWDOOLQJ D JDV

line, a shutoff valve designed for installation 
outside the appliance is recommended.
1.  Remove knockout indentation on refrac-

WRU\RU¿UHEULFNZDOOORFDWHGDSSUR[LPDWHO\
DERYHWKHUHIUDFWRU\KHDUWKÀRRU7KH

knockout  indentation  must  be  firmly 
tapped  with  any  solid  object  such  as  a 
1/2"  dowel  until  it  is  released.  Remove 
fragmented  portions  of  refractory  (see 
Figure 28).

2.  Remove gas line cover plate located on 

UHDU RI ¿UHSODFH DQG SXOO RXW LQVXODWLRQ

from gas line conduit sleeve. Save insula-
tion for reuse. 

 5XQEODFNLURQJDVOLQHLQWRWKH¿UHER[

through the rear at 11 

1

/

4

IURPÀRRUDQG

through gas line conduit sleeve (if using 
a  raised  platform,  add  height).  Provide 

VXI¿FLHQW JDV OLQH LQWR ¿UHER[ FKDPEHU
IRU¿WWLQJFRQQHFWLRQVHH)LJXUH

 

Note:  Secure  incoming  gas  line  to  wood 

IUDPLQJWRSURYLGHULJLGLW\IRUWKUHDGHGHQG

4.  Repack insulation around gas line and into 

sleeve opening. Seal any gaps between 
gas line and refractory knockout hole with 
refractory cement or commercial furnace 
cement, Install the gas appliance or cap 
off gas line if desired.

Seal 
Opening 
with 
Refractory 
Cement

Outside of 
Fireplace

Gas 
Line 
Conduit

Repack 
Insulation

Incoming 
1/2" Black 
Iron Pipe

Side 
Firebrick 
Finished 
Side

Provide Enough Threaded 
End for Fitting Connection

Figure 29 - Gas Line Installation

OPTIONAL GAS LINE INSTALLATION

 &$87,21 $OO JDV SLSLQJ

and connections must be tested 
for  leaks  after  the  installation 
is  completed.  After  ensuring 
that the gas valve is on, apply 
soap  and  water  solution  to  all 

FRQQHFWLRQVDQGMRLQWV%XEEOHV
IRUPLQJ VKRZ D OHDN &RUUHFW
DOOOHDNVDWRQFH'212786(
$1 23(1 )/$0( )25 /($.
7(67,1*$1''212723(5

-

$7($1<$33/,$1&(,)$/($.
,6'(7(&7('/($.7(67,1*
6+28/'%('21(%<$48$/,

-

),('6(59,&(3(5621

The  gas  pipe  is  intended  for  connection  to 
an unvented gas log set or a decorative gas 
appliance. 
If  using  an  unvented  gas  log  set,  ONLY 
UNVENTED GAS LOG SETS WHICH HAVE 
BEEN  FOUND  TO  COMPLY  WITH  THE 
STANDARDS  FOR  UNVENTED  ROOM 
HEATERS, ANS  Z21.11.2, ARE  TO  BE  IN-
STALLED IN THIS FIREBOX.
If  installing  a  decorative  gas  appliance,  the 
decorative  gas  appliance  must  comply  with 
the 

Standard for Decorative Gas Appliances 

for Installation in Solid Fuel Burning Fireplac-

HV$16=

 and shall also be installed in 

accordance with the 

National Fuel Gas code, 

$16=

.

Содержание THE WINDSOR 368 ST

Страница 1: ...URYHG WR 16 Z21 60 Z21 84 standards or for use with a vent free gas ORJ KHDWHU DSSURYHG WR 16 VWDQGDUG 7KLV ZRRG EXUQLQJ UHER FRPSOLHV ZLWK 8 1 8 6 6 0 VWDQGDUG DV D 725 8 7 33 1 DQG LV OLVWHG DQG WHV...

Страница 2: ...ER XQ less the manufacturer s instruc WLRQV ZLWK WKH LQVHUW VSHFL FDOO VWDWH WKLV UHER KDV EHHQ WHVWHG for use with the insert 7KLV UHER LV QRW LQWHQGHG WR EH usedasasubstituteforafurnace WR KHDW DQ H...

Страница 3: ...stir the logs while they are burn LQJ 8VH RQO UH ORJV WKDW KDYH beenevaluatedfortheapplication LQ UHSODFH DQG UHIHU WR UH ORJ warnings and caution markings on packaging prior to use 51 1 KLOGUHQ DQG D...

Страница 4: ...Figure 3 Firebox Clearances Existing Wall Projected Wall FP WR Perpendicular Wall 6 7 1 2 7 21 7R GHWHUPLQH WKH VDIHVW DQG PRVW HI FLHQW ORFDWLRQ IRU WKH UHER RX PXVW WDNH LQWR consideration the follo...

Страница 5: ...tal Front Face 2 3 4 Max 6 98 cm 5 0 1 UDPH WKH RSHQLQJ IRU WKH UHER XVLQJ the dimensions shown in Figures 6 and 7 depending on your installation I UHER LV WR EH LQVWDOOHG GLUHFWO RQ carpeting tile ot...

Страница 6: ...earth Extension Z Type Ember Protector Noncombustible Hearth Extension Ember Protector Figure 11 Raised Hearth Extension Figure 9 Nailing Flanges Nailing Flanges Prepared Framing Nails or Screws 1 2 1...

Страница 7: ...in the required clearance between the chimney and the combustible materials KHQ SHQHWUDWLQJ D RRU RU FHLOLQJ DW DQ DQJOH XVH UHVWRS VSDFHU QXPEHU 6 0 VHH Replacement and Accessory Parts page 14 When t...

Страница 8: ...top Spacer Screws or Staples Min of 8 Existing Ceiling Frame 2 5 1cm Minimum Angled Firestop Ceiling Support Return Elbow 30 FT 9 14m 30 FT 9 14m Figure 16 Elbow Offset Return Elbow 12S 8DM Support Re...

Страница 9: ...ve the roof line use support wires to keep chimney secure Support wires may be attached to outer pipe of chimney with screws if screws do not SHQHWUDWH LQQHU XH SLSH 0 1 080 0 080 01 7 The minimum hei...

Страница 10: ...and LJXUH SDJH Figure 24 Storm Collar Chimney Pipe Waterproof Caulk Storm Collar Flashing 6 1 167 7 21 HWHUPLQH DVKLQJ WR EH XVHG ZLWK URRI RSHQ LQJ FKDUW 6OLGH DVKLQJ RYHU SLSH XQWLO EDVH LV DW DJDLQ...

Страница 11: ...HU IRU VSHFL FDWLRQV 1 6 1 5 2 QVWDOOLQJ LUHER DFLQJ Any noncombustible material may be used for facing glass tile brick etc as long as SURSHU FOHDUDQFHV DUH DGKHUHG WR DQG UHER openings are not obstr...

Страница 12: ...HFWLRQ VHH LJXUH Note Secure incoming gas line to wood IUDPLQJ WR SURYLGH ULJLGLW IRU WKUHDGHG HQG 4 Repack insulation around gas line and into sleeve opening Seal any gaps between gas line and refrac...

Страница 13: ...DWLRQ GRRUV PXVW EH IXOO RSHQ RU IXOO FORVHG SRVLWLRQ RQO RU D UH KD DUG PD EH FUHDWHG VHH LJXUH RU UHER HTXLSSHG ZLWK JODVV GRRUV RSHUDWHV PXFK GLIIHUHQWO WKDQ D UHER ZLWK DQ RSHQ IURQW UHER ZLWK JOD...

Страница 14: ...FKLOGUHQ VKRXOG EH FDUH fully supervised when they are in WKH VDPH URRP DV UHER TECHNICAL SERVICE You may have further questions about instal lation operation or troubleshooting If so contact FMI PROD...

Страница 15: ...able in triple wall 28 3 3 6833257 66 0 6 0 28 2 2 6 7 0 5 6723 63 5 6 0 for Straight 3LSH 212 723 7 50 1 7 21 7 0 7 2 0 Vent Plaster Collar Vent Hood Connector Duct 4 x 3 Return Elbow Starter Elbow 6...

Страница 16: ...55511 Rev F 67 UXVKHG UDVV 67 3ODWLQXP 3 67 ODFN REPLACEMENT AND ACCESSORY PARTS Continued 2 66 2256 6 DUERU OYG 6DQWD QD 1 866 328 4537 www fmiproducts com...

Отзывы: