background image

www.fmiproducts.com

108796-01U

18

oPeratIoN

1.  STOP!  Read  the  safety  information,  in 

column 1.

2.  Turn off all electric power to appliance.

3.  Turn wall switch to the OFF position.
4.  Fully open glass doors if installed.
5.  Remove  front  refractory  brick  access 

panel.

6.  Turn equipment shutoff valve clockwise 

 to the OFF position (see Figure 

37). Do not force.

7.  Wait five (5) minutes to clear out any gas. 

Then  smell  for  gas,  including  near  the 

floor. If you smell gas, STOP! Follow “B” 

in  the  safety  information,  above.  If  you 

don’t smell gas, go to the next step.

8.  Turn  equipment  shutoff  valve  counter

-

clockwise 

 to the ON position. Do 

not force.

9.  Replace  front  refractory  brick  access 

panel.

10. Fully close glass doors if installed.

11. Turn on all electric power to appliance.

12. Turn wall switch to the ON position.
13. Visually  locate  pilot. The  ignitor  should 

begin  to  spark  and  main  burner  should 

ignite once flame appears at pilot.
• If lighting appliance for the first time each 

season,  it  may  take  several  attempts 

before the supply gas can reach the pilot 

and main burners.

• If  the  appliance  will  not  stay  lit  after 

several attempts, follow the instructions 

To Turn Off Gas To Appliance

, page 19, 

and call your service technician or gas 

supplier.

Figure 37 - Turning Equipment Shutoff 

Valve to the OFF Position

Equipment 

Shutoff Valve

Adjustment 

Screw

FOR YOUR SAFETY 

READ BEFORE LIGHTING

 WARNING: If you do not fol-

low these instructions exactly, 

a  fire  or  explosion  may  result 

causing property damage, per

-

sonal injury or loss of life.

A.  This appliance has a pilot which must 

be  lighted  by  hand.  When  lighting 

the  pilot,  follow  these  instructions 

exactly.

B.  BEFORE  LIGHTING  smell  all  around 

the appliance area for gas. Be sure to 

smell next to the floor because some 

gas is heavier than air and will settle 

on the floor.

 

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do 

not use any phone in your building.

• Immediately  call  your  gas  supplier 

from a neighbor’s phone. Follow the 

gas supplier’s instructions.

• If you cannot reach your gas supplier, 

call the fire department.

C.  Use only your hand to push in or turn 

the gas control knob. Never use tools. 

If the knob will not push in or turn by 

hand, don’t try to repair it, call a quali

-

fied service technician or gas supplier. 

Force or attempted repair may result in 

a fire or explosion.

D.  Do not use this appliance if any part 

has  been  under  water.  Immediately 

call  a  qualified  service  technician  to 

inspect the appliance and to replace 

any  part  of  the  control  system  and 

any gas control which has been under 

water.

LIGHTING 

INSTRUCTIONS

NOTICE: During initial operation 

of new heater, burning logs will 

give off a paper-burning smell. 

Orange flame will also be pres

-

ent. Open damper or window to 

vent smell. This will only last a 

few hours.

Содержание M36E, M36E

Страница 1: ...GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instruction...

Страница 2: ...nce may be installed in an aftermarket per manently located manufactured mobile home where not prohibited by state or local codes This appliance is only for use with the type of gas indi cated on the...

Страница 3: ...rating plate This appliance is not convertible for use with other gases unless a certified kit is used 2 For propane LP fireplace do not place propane LP supply tank s inside any structure Locate prop...

Страница 4: ...pped on cardboard Three 3 plastic bags containing lava rock pan and ember materials Rear Log Remove two plastic quick ties from around burner and grate Grate Stand Lift off of burner pan Check all ite...

Страница 5: ...ly piping system at test pressures equal to or less than 1 2 psig 3 5 kPa For the purpose of input adjustment two pressure taps for IN and OUT pressures are provided on the gas control valve for test...

Страница 6: ...2 66 kPa 10 5 WC 2 66 kPa Orifice Size 30 29 GAS RATING PROPANE LP M36P B H VM36P B H M42P B H VM42P B H Max Input Rating 40 000 Btu Hr 45 000 Btu Hr Manifold Pressure 10 WC 2 49 kPa 10 WC 2 49 kPa M...

Страница 7: ...ents in relation to fireplace opening Spacer 3 7 6 cm 1 1 2 3 8 cm Max B 6 15 2 cm A 12 22 9 cm Combustible Materials Header Figure 5 Mantel Clearances Side View Cross Section 1 1 2 3 8 cm Max 3 7 6 c...

Страница 8: ...ack iron pipe does not mate with fitting at the end of flexible gas line remove fitting and replace with a 37 degree flare 3 4 12 1 2 NPT female fitting WARNING When finishing appliance do not overlap...

Страница 9: ...st terminate vertically into a listed type vent cap and extend a sufficient height through an approved roof flashing roof jack or a roof thimble At all points the listed clearances must be maintained...

Страница 10: ...r installation It is not recommended that this appliance be common vented with an existing gas burning appliance However if it becomes necessary to common vent this appliance the venting system must b...

Страница 11: ...te Control Receiver Extension Cord Ignition Module Plug NOTICE This appliance is equipped with a vent safety shutoff switch which will shut down the appliance in the case of aventingproblem Donotbypas...

Страница 12: ...TS LLC recommends that a black iron gas line be routed from the gas source through a sediment trap shown in Figure 18 and into appliance Once con nected through appliance a flexible gas line may be us...

Страница 13: ...appear leaks can be detected and corrected Donotuseanopenflameforleak testing and do not operate any appliance if a leak is detected Installation Continued Complete your gas installation by connect in...

Страница 14: ...5 into notch on left of log 2 see Figure 25 Rest lower end of log 5 on grate as shown in Figure 26 6 Insert lower end of log 6 between first two grate fingers as shown in Figure 26 and position upper...

Страница 15: ...5 Place upper end of log 5 into notch on top inner right of log 1 see Figure 29 Rest lower end of log 5 on middle grate finger as shown in Figure 30 6 Place log 6 into notch on top right of log 1 see...

Страница 16: ...Sealing Between Appliance and Framing Installing optional GLASS DOOR Accessory CAUTION Use only glass doors certified for use with this appliance Note Glass door may be heavy for some individuals If...

Страница 17: ...is free of clip 2 Fully fold frame assembly and slide upper edge towards center of firebox opening until guide pins are free of frame rail see Figure 35 CAUTION Always operate the appliance with the...

Страница 18: ...toff Valve Adjustment Screw FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not fol low these instructions exactly a fire or explosion may result causing property damage per sonal injury or los...

Страница 19: ...sure to press ON OFF buttons on hand held remote control unit for up to 3 seconds to assure proper operation 2 Press the ON OFF button to turn burner on and off Check pilot flame pattern and burner f...

Страница 20: ...and replace when cleaning is complete Burner and controls should be cleaned with compressed air to remove dust dirt or lint Use a vacuum cleaner or small soft bristled brush to remove excess dust dir...

Страница 21: ...ne Wiring Diagram Service Hints When Gas Pressure Is Too Low pilot will not stay lit burner will have delayed ignition fireplace will not produce specified heat propane LP gas supply may be low if usi...

Страница 22: ...ltage REMEDY 1 Check to see if you have gas supply and that equipment shutoff valve is opened 2 Repeat lighting procedure several times to purge all air out of lines If after repeated attempts applian...

Страница 23: ...pane LP gas low fuel supply 3 Gas leak See Warning statement at top of page 1 Gas leak See Warning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner...

Страница 24: ...36EP B H M42E B H M42EP B H VM36E B H VM36EP B H VM42E B H and VM42EP B H 51 21 1 10 11 6 50 50 22 3 8 20 9 52 13 43 14 45 48 62 44 40 23 4 39 17 2 42 41 9 55 7 46 19 47 7 47 18 5 16 12 15 52 33 31 28...

Страница 25: ...Deflector 1 25 11165 11165 Screw 10 x 5 8 2 26 107796 01 107796 02 Grate Assy 1 27 107742 01 107742 02 Burner Pan 1 28 107795 01 107831 01 Burner Tube 1 29 107748 01 107748 01 Burner Brckt 1 30 107985...

Страница 26: ...M42EH 1 106660 01 107816 01 Rear Refractory Std Brick VM36EB VM42EB 1 108166 01 108171 01 Rear Refractory Herringbone VM36EH VM42EH 1 15 106661 02 107818 02 Bottom Rear Refractory Std Brick M36 ME42...

Страница 27: ...and VM36P B H KEY NO PART NO DESCRIPTION QTY 107999 01 Log Set 1 108724 01 Right Front 9 Split Log 1 2 901098 01 Rear Log 1 3 108720 01 Top Right Log 11 3 4 1 4 108721 01 Top Right Log 16 1 5 108722 0...

Страница 28: ...01 Left Front Log 11 1 2B 108839 01 Right Front Log 15 3 4 Round 1 3 108722 01 Top Left Log 13 1 2 Y Log 1 4 108838 01 Inside Top Left Log 15 3 4 Split 1 5 108721 01 Inside Top Right Log 16 1 6 108720...

Страница 29: ...M42 B H and M42P B H BL36 36 Refractory Standard Brick BL42 42 Refractory Standard Brick BL36H 36 Refractory Herringbone Brick BL42H 42 Refractory Herringbone Brick For VM36 B H VM36P B H VM42 B H and...

Страница 30: ...______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____...

Страница 31: ..._______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ___...

Страница 32: ...product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic mat...

Отзывы: