background image

www.fmiproducts.com

108796-01UT

3

saFety

 WARNING: This product con-

tains and/or generates chemicals 

known to the State of California 

to cause cancer or birth defects 

or other reproductive harm.

IMPORTANT: Read this owner’s 

manual carefully and completely 

before trying to assemble, op

-

erate  or  service  this  fireplace. 

Improper  use  of  this  fireplace 

can cause serious injury or death 

from  burns,  fire,  explosions, 

electrical  shock  and  carbon 

monoxide poisoning.

 DANGER: Carbon monoxide 

poisoning may lead to death!

This fireplace is a vented product. This fireplace 

will not produce any gas leakage into your home 

if  properly  installed. This  fireplace  must  be 

properly installed by a qualified service person. 

If this unit is not properly installed by a qualified 

service person, gas leakage can occur.

Carbon Monoxide Poisoning:

 Early signs of 

carbon monoxide poisoning resemble the flu, 

with headaches, dizziness or nausea. If you 

have these signs, the fireplace may not have 

been installed properly. 

Get fresh air at once!

 

Have fireplace inspected and serviced by a 

qualified service person. Some people are more 

affected by carbon monoxide than others. These 

include pregnant women, people with heart or 

lung disease or anemia, those under the influ

-

ence of alcohol and those at high altitudes.
Propane/LP  gas  and  natural  gas  are  both 

odorless. An  odor-making  agent  is  added 

to each of these gases. The odor helps you 

detect a gas leak. However, the odor added 

to these gases can fade. Gas may be present 

even though no odor exists.
Make  certain  you  read  and  understand  all 

warnings. Keep this manual for reference. It 

is your guide to safe and proper operation of 

this fireplace.

  WARNING:  Any  change  to 

this fireplace or its controls can 

be dangerous.

1.  This appliance is only for use with the type 

of gas indicated on the rating plate. This 

appliance is not convertible for use with 

other gases unless a certified kit is used.

2.  For  propane/LP  fireplace,  do  not  place 

propane/LP  supply  tank(s)  inside  any 

structure.  Locate  propane/LP  supply 

tank(s) outdoors. To prevent performance 

problems, do not use propane/LP fuel tank 

of less than 100 lbs. capacity.

3.  If you smell gas

• shut off gas supply

• do not try to light any appliance

• do not touch any electrical switch; do not 

use any phone in your building

• immediately call your gas supplier from 

a neighbor’s phone. Follow the gas sup

-

plier's instructions

• if you cannot reach you gas supplier, call 

the fire department.

4.  Never install the fireplace 

• in a recreational vehicle

• where curtains, furniture, clothing or other 

flammable objects are less than 36" from 

front and 42" from top of fireplace. For 

side clearances see Figure 6, page 7

• in high traffic areas

• in windy or drafty areas

5.  This fireplace reaches high temperatures. 

Keep children and adults away from hot 

surfaces to avoid burns or clothing igni

-

tion. Fireplace will remain hot for a time 

after  shutdown. Allow  surfaces  to  cool 

before touching.

6.  Carefully supervise young children when 

they are in the room with fireplace.

7.  A hearth extension is not required with this 

appliance. If one is installed, it is for aes

-

thetic purposes only and does not have 

to meet the standard requirements.

8.  Turn fireplace off and let cool before ser

-

vicing or repairing. Only a qualified service 

person  should  install,  service  or  repair 

this  fireplace.  Have  fireplace  inspected 

annually by a qualified service person.

9.  You  must  keep  control  compartments, 

burners and circulating air passages clean. 

More frequent cleaning may be needed due 

to excessive lint and dust from carpeting, 

bedding material, etc. Turn off the gas valve 

and pilot light before cleaning fireplace.

10. Have venting system inspected annually by 

a qualified service person. If needed, have 

venting system cleaned or repaired. See 

Cleaning and Maintenance

, page 20.

Содержание M36E, M36E

Страница 1: ...GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instruction...

Страница 2: ...nce may be installed in an aftermarket per manently located manufactured mobile home where not prohibited by state or local codes This appliance is only for use with the type of gas indi cated on the...

Страница 3: ...rating plate This appliance is not convertible for use with other gases unless a certified kit is used 2 For propane LP fireplace do not place propane LP supply tank s inside any structure Locate prop...

Страница 4: ...pped on cardboard Three 3 plastic bags containing lava rock pan and ember materials Rear Log Remove two plastic quick ties from around burner and grate Grate Stand Lift off of burner pan Check all ite...

Страница 5: ...ly piping system at test pressures equal to or less than 1 2 psig 3 5 kPa For the purpose of input adjustment two pressure taps for IN and OUT pressures are provided on the gas control valve for test...

Страница 6: ...2 66 kPa 10 5 WC 2 66 kPa Orifice Size 30 29 GAS RATING PROPANE LP M36P B H VM36P B H M42P B H VM42P B H Max Input Rating 40 000 Btu Hr 45 000 Btu Hr Manifold Pressure 10 WC 2 49 kPa 10 WC 2 49 kPa M...

Страница 7: ...ents in relation to fireplace opening Spacer 3 7 6 cm 1 1 2 3 8 cm Max B 6 15 2 cm A 12 22 9 cm Combustible Materials Header Figure 5 Mantel Clearances Side View Cross Section 1 1 2 3 8 cm Max 3 7 6 c...

Страница 8: ...ack iron pipe does not mate with fitting at the end of flexible gas line remove fitting and replace with a 37 degree flare 3 4 12 1 2 NPT female fitting WARNING When finishing appliance do not overlap...

Страница 9: ...st terminate vertically into a listed type vent cap and extend a sufficient height through an approved roof flashing roof jack or a roof thimble At all points the listed clearances must be maintained...

Страница 10: ...r installation It is not recommended that this appliance be common vented with an existing gas burning appliance However if it becomes necessary to common vent this appliance the venting system must b...

Страница 11: ...te Control Receiver Extension Cord Ignition Module Plug NOTICE This appliance is equipped with a vent safety shutoff switch which will shut down the appliance in the case of aventingproblem Donotbypas...

Страница 12: ...TS LLC recommends that a black iron gas line be routed from the gas source through a sediment trap shown in Figure 18 and into appliance Once con nected through appliance a flexible gas line may be us...

Страница 13: ...appear leaks can be detected and corrected Donotuseanopenflameforleak testing and do not operate any appliance if a leak is detected Installation Continued Complete your gas installation by connect in...

Страница 14: ...5 into notch on left of log 2 see Figure 25 Rest lower end of log 5 on grate as shown in Figure 26 6 Insert lower end of log 6 between first two grate fingers as shown in Figure 26 and position upper...

Страница 15: ...5 Place upper end of log 5 into notch on top inner right of log 1 see Figure 29 Rest lower end of log 5 on middle grate finger as shown in Figure 30 6 Place log 6 into notch on top right of log 1 see...

Страница 16: ...Sealing Between Appliance and Framing Installing optional GLASS DOOR Accessory CAUTION Use only glass doors certified for use with this appliance Note Glass door may be heavy for some individuals If...

Страница 17: ...is free of clip 2 Fully fold frame assembly and slide upper edge towards center of firebox opening until guide pins are free of frame rail see Figure 35 CAUTION Always operate the appliance with the...

Страница 18: ...toff Valve Adjustment Screw FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not fol low these instructions exactly a fire or explosion may result causing property damage per sonal injury or los...

Страница 19: ...sure to press ON OFF buttons on hand held remote control unit for up to 3 seconds to assure proper operation 2 Press the ON OFF button to turn burner on and off Check pilot flame pattern and burner f...

Страница 20: ...and replace when cleaning is complete Burner and controls should be cleaned with compressed air to remove dust dirt or lint Use a vacuum cleaner or small soft bristled brush to remove excess dust dir...

Страница 21: ...ne Wiring Diagram Service Hints When Gas Pressure Is Too Low pilot will not stay lit burner will have delayed ignition fireplace will not produce specified heat propane LP gas supply may be low if usi...

Страница 22: ...ltage REMEDY 1 Check to see if you have gas supply and that equipment shutoff valve is opened 2 Repeat lighting procedure several times to purge all air out of lines If after repeated attempts applian...

Страница 23: ...pane LP gas low fuel supply 3 Gas leak See Warning statement at top of page 1 Gas leak See Warning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner...

Страница 24: ...36EP B H M42E B H M42EP B H VM36E B H VM36EP B H VM42E B H and VM42EP B H 51 21 1 10 11 6 50 50 22 3 8 20 9 52 13 43 14 45 48 62 44 40 23 4 39 17 2 42 41 9 55 7 46 19 47 7 47 18 5 16 12 15 52 33 31 28...

Страница 25: ...Deflector 1 25 11165 11165 Screw 10 x 5 8 2 26 107796 01 107796 02 Grate Assy 1 27 107742 01 107742 02 Burner Pan 1 28 107795 01 107831 01 Burner Tube 1 29 107748 01 107748 01 Burner Brckt 1 30 107985...

Страница 26: ...M42EH 1 106660 01 107816 01 Rear Refractory Std Brick VM36EB VM42EB 1 108166 01 108171 01 Rear Refractory Herringbone VM36EH VM42EH 1 15 106661 02 107818 02 Bottom Rear Refractory Std Brick M36 ME42...

Страница 27: ...and VM36P B H KEY NO PART NO DESCRIPTION QTY 107999 01 Log Set 1 108724 01 Right Front 9 Split Log 1 2 901098 01 Rear Log 1 3 108720 01 Top Right Log 11 3 4 1 4 108721 01 Top Right Log 16 1 5 108722 0...

Страница 28: ...01 Left Front Log 11 1 2B 108839 01 Right Front Log 15 3 4 Round 1 3 108722 01 Top Left Log 13 1 2 Y Log 1 4 108838 01 Inside Top Left Log 15 3 4 Split 1 5 108721 01 Inside Top Right Log 16 1 6 108720...

Страница 29: ...M42 B H and M42P B H BL36 36 Refractory Standard Brick BL42 42 Refractory Standard Brick BL36H 36 Refractory Herringbone Brick BL42H 42 Refractory Herringbone Brick For VM36 B H VM36P B H VM42 B H and...

Страница 30: ...______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____...

Страница 31: ..._______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ___...

Страница 32: ...product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic mat...

Отзывы: