www.fmiproducts.com
125326-01A
21
SPECIFICATIONS
GWN10A, VSHN10M
• Natural Gas Only
• 5,500/10,000 Btu/h
• Piezo Ignition
• Pressure Regulator Setting: 3" W.C.
• Inlet Gas Pressure* (in. of water):
Maximum - 10.5" W.C., Minimum - 4" W.C.
GWN10TA, VSHN10T
• Natural Gas Only
• 5,000/10,000 Btu/h
• Piezo Ignition
• Pressure Regulator Setting: 3" W.C.
• Inlet Gas Pressure* (in. of water):
Maximum - 10.5" W.C., Minimum - 4" W.C.
GWP10A, VSHP10M
• Propane/LP Gas Only
• 5,500/10,000 Btu/h
• Piezo Ignition
• Pressure Regulator Setting: 8" W.C.
• Inlet Gas Pressure* (in. of water):
Maximum - 14" W.C., Minimum - 11" W.C.
GWP10TA, VSHP10A
• Propane/LP Gas Only
• 5,000/10,000 Btu/h
• Piezo Ignition
• Pressure Regulator Setting: 8" W.C.
• Inlet Gas Pressure* (in. of water):
Maximum - 14" W.C., Minimum - 11" W.C.
TECHNICAL SERVICE
You may have further questions about installa
-
tion, operation or troubleshooting. If so, contact
FMI PRODUCTS, LLC at 1-866-328-4537.
When calling please have your model and
serial numbers of your heater ready.
You can also visit our web site at
www.fmiproducts.com
.
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low
You may feel your gas pressure is too low. If
so, contact your local natural or propane/LP
gas supplier.
REPLACEMENT PARTS
Note: Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call FMI PRODUCTS, LLC at
1-866-328-4537.
When calling, have ready:
• your name
• your address
• model and serial numbers of your heater
• how heater was malfunctioning
• type of gas used (propane/LP or natural
gas)
• purchase date
Usually, we will ask you to return the part to
the factory.