21
107599
OWNER’S MANUAL
For more information, visit www.desatech.com
STOVE AND
DIRECT-VENT
BURNER SYSTEM
INSTALLATION
Continued
Pressure Testing Burner
System Gas Connections
1.
Open equipment shutoff valve (see Fig-
ure 45, page 20).
2.
Open propane/LP supply tank valve for
propane/LP burner system or main gas
valve located on or near gas meter for
natural gas burner system.
3.
Make sure control knob of burner sys-
tem is in the OFF position.
4.
Check all joints from equipment shutoff
valve to thermostat gas valve (see Fig-
ure 46 for propane/LP or Figure 47 for
natural). Apply commercial leak test so-
lution to all gas joints. Bubbles forming
show a leak. Correct all leaks at once.
5.
Light burner system (see Operating
Stove with Burner System, pages 25
through 27). Check all other internal
joints for leaks.
6.
Turn off burner system (see To Turn Off
Gas to Appliance, page 25).
Figure 46 - Checking Gas Joints for Propane/LP Gas Burner System
Propane/
LP Supply
Tank
Equipment Shutoff Valve
Gas Valve
Equipment Shutoff Valve
Gas Valve
Gas Meter
Figure 47 - Checking Gas Joints for Natural Gas Burner System
Continued