Flame is dim or not 
present 

1.  Dimmer control button is set too 

low. 

2.  Light bulbs are burned out.

 

 
3.  “Flame wand” has come loose 

from bracket. 

 
4.  “Flame wand” motor is not 

functioning. 

1.  Push button E“+” to increase light.

 

2.  Inspect light bulbs and replace if 

necessary.    (see Maintenance 
section of this manual) 

3.  Remove back panel.    Secure 

end of “flame wand” back into the 
support bracket. 

4.  Call FMI Technical Service at

 1-866-328-4537.

 

The appliance turns off 
and will not turn back on 

1.  The overheat protection device in 

the appliance has been triggered. 

 
2.  House circuit breaker has been 

tripped. 

1.  Turn all controls off, unplug the 

appliance, allow to cool for at 
least 10 minutes, then plug back 
in and restart. 

2.  Reset house circuit breaker. 

The appliance does not 
turn on when the button is 
pushed to “ON” 

1.  The overheat protection device in 

the appliance has been triggered. 

1.  Turn all controls off, unplug the 

appliance, allow to cool for at 
least 10 minutes, then plug back 
in and restart. 

Remote control does not 
work 

2.  Low batteries. 
 
3.  Manual controls on the appliance 

must be ON ” before operating 
the remote control.

 

1.  Replace all batteries in the 

remote control. 

2.  Push the appliance “ON” using

 the manual control panel, then 
use remote control to operate.   

If using the remote control to 

operate the appliance, you must 

 also turn the  appliance “ON”  

 using the remote control.

 

 

Problem

Possible Cause

Corrective Action

“ 

7

Содержание FEF26

Страница 1: ...FMI PRODUCTS LLC 26 IN ELECTIC FIREPLACE MODEL FEF26 Optional face trim kit model FT26 F2609E FMI products LLC 1...

Страница 2: ...Service Replacement Parts 8 Warranty 9 TABLE OF CONTENTS Safety Information 3 Operation Instructions 4 Installation Instructons 5 Care and Maintenance 6 Troubleshooting 7 2...

Страница 3: ...e plug from the electrical outlet 8 The appliance comes equipped with a 3 prong grounding plug Do not cut the grounding prong Connect to properly grounded 120V outlets only 9 Do not insert or allow fo...

Страница 4: ...indow on the front Fig 1 Fig 1 Fig 2 Using the Control Panel and the Remote Control Simulated Flame Effect o Push button A power ON OFF o Push button D to turn the flame ON OFF o Push button E to flam...

Страница 5: ...g plug extending from the adapter must be securely connected to a permanent ground such as a properly grounded outlet box The adapter should only be used if a proper 3 slot receptacle is not available...

Страница 6: ...See Fig 6 Examine the light bulbs to determine which bulbs require replacement Remove the burnt out bulb and replace with a new 40W bulb Replace the cover panel See Fig 7 do not over tighten To remove...

Страница 7: ...device in the appliance has been triggered 2 House circuit breaker has been tripped 1 Turn all controls off unplug the appliance allow to cool for at least 10 minutes then plug back in and restart 2...

Страница 8: ...E BACK COVER 1 11 125379 01 MOTOR 1 12 125380 01 PLASTIC FOOT 4 13 125381 01 LAMP HOLDER 3 14 125382 01 LAMP 3 15 125383 01 FAN AND HEATER 1 16 125384 01 SIMULATED FIRE LOG GRATE 1 17 125385 01 SWITCH...

Страница 9: ...this product to proper operating condition and an allowance for labor when provided by a FMI PRODUCTS LLC Authorized Service Center or a provider approved by FMI PRODUCTS LLC Warranty parts must be ob...

Отзывы: