DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

DVFH34, DVFH34P

INSTALLING OPTIONAL
BLOWER ACCESSORY

IMPORTANT

: For clarity, gas valve assem-

bly and grate/burner assembly are not shown
in Figures 29 through 32, page 17. They will,
however, be in your fireplace when you are
installing the blower. Also for clarity the
firebox is shown with dotted lines.

1.

Open lower louver panel or remove for
easier access.

2.

Place the blower against the lower rear
wall of firebox outer wrapper with the
exhaust port directed upward. Align the
holes in the top mounting tabs of
blower with holes in wall of wrapper
(see Figure 29, page 17). Using the two
screws provided, mount blower and
tighten screws securely.

Note:

 For DA3610TA, make sure the

thermal switch is comfortably between
the back of the firebox and the blower
as shown in Figure 30, page 17.

3.

Be sure to securely attach all wire ter-
minals to terminals on blower motor
(and thermal switch where applicable)
and that the screw retaining the green
ground wire is tight.

4.

Remove screws securing the switch plate
to the bottom of the firebox and set aside.

5.

Place speed control against back of this
plate and push the plastic control shaft
through opening (see Figure 31, page 17).

6.

While supporting speed control, secure
control shaft with lock nut by pushing
and turning lock nut with pliers clock-
wise until tight against the plate. Place
control knob provided onto shaft (see
Figure 31, page 17).

7.

Replace plate containing the switch and
tighten screws securely.

NOTICE: If installing blower in an
existing fireplace with gas con-
nections, shut off gas supply and
disconnect heater from gas sup-
ply. Contact a qualified service
person to do this.

CHECK GAS TYPE

Use proper gas type for the fireplace unit
you are installing. If you have conflicting
gas types, do not install fireplace. See re-
tailer where you purchased the fireplace for
proper fireplace according to your gas type.

FIREPLACE
INSTALLATION

 WARNING: A qualified ser-

vice person must install fireplace.
Follow all local codes.

 CAUTION: This fireplace cre-

ates warm air currents. These cur-
rents move heat to wall surfaces
next to fireplace. Installing fire-
place next to vinyl or cloth wall
coverings or operating fireplace
where impurities (such as to-
bacco smoke, aromatic candles,
cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may
discolor walls.

Note: 

Your fireplace is designed to be used

in zero clearance installations. Wall or fram-
ing material can be placed directly against
any exterior surface on the rear, sides, or top
of your fireplace, except where standoff
spacers are integrally attached. If standoff
spacers are attached to your fireplace, these
spacers can be placed directly against wall
or framing material. See framing details on
page 4.

Place the fireplace into position and shim
with noncombustible material if needed.
Nail the side flanges to the framing to secure
the unit in place. There are two floor brack-
ets included with each unit. Use these as an
alternative method of securing the fireplace.

IMPORTANT: 

Make sure fireplace is level

before securing. If fireplace is not level it
will not work properly.

Attaching Thermal Switch to
DA3610TA Thermostatically-
Controlled Blower

When installing the DA3610T thermostati-
cally-controlled blower accessory, you must
first secure the thermal switch to the blower.

1.

Remove the two hex head screws on the
blower assembly as shown in Figure 28.

2.

Place the green wire between the bot-
tom hole on the thermal switch bracket
and the bottom hole on the blower as-
sembly.  Insert one of the hex screws
into all three pieces and tighten.

3.

Insert the top screw through the ther-
mal switch bracket and into the blower
assembly. Tighten screw.

4.

Connect the blue wire on the blower
assembly to the right side of the ther-
mal switch.

5.

Connect the black wire to the left side
of the thermal switch.

Installing GA3700/DA3610TA
Blowers

Figure 28 - Attaching Thermal Switch to DA3610TA Thermostatically-Controlled
Blower Accessory

Blower Assembly

Blue Wire

Green Wire

Black Wire

White Wire

Hex Head
Screws

Thermal Switch
with Bracket

NOTICE: This fireplace is in-
tended for use as supplemental
heat. Use this fireplace along with
your primary heating system. Do
not install this fireplace as your
primary heat source. If you have
a central heating system, you may
run system’s circulating blower
while using fireplace. This will
help circulate the heat through-
out the house. In the event of a
power outage, you can use this
fireplace as a heat source.

Содержание DVFH34

Страница 1: ...assis tanceoradditionalinformationcon sult a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket manufactured mobile home where not prohibited by s...

Страница 2: ...cated on fire place nameplate 14 This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electri cal Code ANS NFPA...

Страница 3: ...IGNITOR This fireplace has a piezo ignitor This sys tem requires no matches batteries or other sources to light fireplace Figure 1 FMI Direct Vent Fireplace DVFH Series Glass Door Assembly Blower Adju...

Страница 4: ...8 for drywall facing Must maintain a minimum 1 clearance to combustibles 34 3 4 34 1 4 20 Vertical Termination 19 Horizontal Termination CLEARANCES Minimum clearances to combustibles for the fireplac...

Страница 5: ...front of the termination cap Do not locate termination cap where ex cessive snow or ice build up may occur Be sure to clear vent termination area af ter snow falls to prevent accidental block age of...

Страница 6: ...paved side walk or a paved driveway located on public property 84 inches 2133mm minimum M clearance under veranda porch deck 12 inches 305mm minimum N clearance above a roof shall extend a minimum of...

Страница 7: ...n Itisimportanttoselecttheproperlengthofvent pipe for the type of termination you choose It is also important to note the wall thickness For Horizontal Termination Select the amount of vertical rise d...

Страница 8: ...t pipes and fittings have spe cial twist lock connections Assemble the desired combination of pipe and el bows to the appliance adaptor with pipe seams oriented towards the wall or floor Twist lock Pr...

Страница 9: ...or 10 hole on the exterior wall with the arrow on the vent cap pointing up Insure proper clearance of 1 to combustibles is maintained At tach the vent cap with four wood screws supplied see Figure 13...

Страница 10: ...ical pipe 90 elbow 67 min 60 max 79 min 84 max 96 min 20 max Note This configuration for use with corner installation Horizontal Termination Configurations Figures 16 through 19 show different con fig...

Страница 11: ...ax 20 max Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H2 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max 20 max 20 max Figure 18 Horizontal Termination Configuration for Rigid Ve...

Страница 12: ...ure 20 to avoid cutting load bearing members Note Pay special attention to these installation instruc tions for required clearances air space to combustibles when passing through ceilings walls roofs...

Страница 13: ...ack the support box in place through the inside walls and into the roof sheathing 4 Using tin snips cut the supportbox from the top corners down to the roofline and fold the resulting flaps over the r...

Страница 14: ...nued Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 20 max Figure 26 Vertical Rigid Venting Configuration Using Two...

Страница 15: ...LTITUDE INSTALLATION Your FMI direct vent fireplace has been AGA tested and approved for elevations from 0 2000 feet and CGA certified for elevations from 0 4500 feet When installing this fireplace at...

Страница 16: ...place next to vinyl or cloth wall coverings or operating fireplace where impurities such as to bacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may discolor wall...

Страница 17: ...ee Figure 32 Route power cord through both plastic bushing s and plug the power cord into a properly grounded 3 prong wall receptacle near the firebox b If your fireplace system installation is recess...

Страница 18: ...le alternative to test gauge connection Pur chase the CSA design certified equipment shutoff valve from your retailer WARNING A qualified ser vice person must connect fire place to gas supply Follow a...

Страница 19: ...by installer from equipment shutoff valve to fireplace Route flexible gas supply line through one of the access holes on side of fireplace 3 Attach flexible gas line from gas sup ply to control valve...

Страница 20: ...valve see Fig ure 36 2 Open propane LP supply tank valve for propane LPfireplace or main gas valve located on or near gas meter for natu ral gas fireplace 3 Make sure control knob of fireplace is in t...

Страница 21: ...ure 40 Disconnecting TH to TPTH Wire 9 Volt Alkaline Battery Receiver Terminal Wires Battery Clip INSTALLING OPTIONAL WIRELESS HAND HELD REMOTE CONTROL GHRC SERIES GHRCT SERIES NOTICE Use only alkalin...

Страница 22: ...firmly and pull to separate from the base 6 Feed the electrical wires through the rectangular slots from the back on each side of the base see Figure 45 WARNING Do not connect thisthermostattoapowers...

Страница 23: ...el in place while installing side panels 5 Install left side brick panel by sliding it between the grate and the side of the firebox see Figure 50 6 Slide the left retainer bracket against the left si...

Страница 24: ...og as shown in Figure 53 4 Place log 4 right log onto the front left part of the grate making sure the notches fits over the prong of the grate see Figure 54 5 Place lava rock along sides and front of...

Страница 25: ...control knob counterclock wise to PILOT 9 Push in gas control knob all the way and hold Immediately light the pi lot by repeatedly depressing the piezo spark ignitor until a flame appears Continue to...

Страница 26: ...25 OPTIONAL REMOTE OPERATION Thermostat Control Operation Optional GHRCTA Series Only The thermostat control setting on the remote control unit can be set to any comfort level between WARMER and COOL...

Страница 27: ...ling Call a qualified service person to readjust the pilot if necessary The height of the thermopile must be 3 8 to 1 2 abovethepilotflameasshowninFigure 60 The thermocouple must be at a height of abo...

Страница 28: ...ity WARNING Turn off fireplace and let cool before cleaning CAUTION Youmustkeepcon trol areas burners and circulat ing air passageways of fireplace clean Inspect these areas of fire place before each...

Страница 29: ...ose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holdin...

Страница 30: ...er until air is removed from line Have gas line checked by local pro pane LP or natural gas company 3 Clean burner see Cleaning and Mainte nance page 28 or replace burner orifice 1 Adjust the log set...

Страница 31: ...2 Air holes at burner inlet blocked 3 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces unwanted odors Fireplace shuts off in use Gas odor even when control knob is in OFF position Gas od...

Страница 32: ...sconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Note Use only original replacement parts Thiswillprotectyourwarrant...

Страница 33: ...ure 4 5 w c 11 0 w c Thermal Efficiency 70 70 Dimension Inches mm HxWxD Fireplace Actual size of firebox Measurements do not 32 3 16 x 34 3 8 x 18 1 2 32 3 16 x 34 3 8 x 18 1 2 include nailing flanges...

Страница 34: ...H34 DVFH34P ILLUSTRATED PARTS BREAKDOWN DVFH34 DVFH34P 1 2 3 4 6 6 39 5 5 6 5 11 Included in Hardware Pack 7 7 8 10 9 12 13 14 15 16 17 18 19 20 35 21 22 23 24 25 26 27 28 28 29 30 34 1 34 4 34 2 34 3...

Страница 35: ...opane LP 1 19 104498 01 Thermocouple 1 20 104499 01 Thermopile 1 21 104500 01 Ignitor 1 22 104501 01 Ignitor Bracket 1 23 104502 01 Ignitor Screw 1 24 104503 01 Ignitor Wire 1 25 104504 01 Burner Natu...

Страница 36: ...BRICK LINER D8037A Not Shown This brick liner adds a touch of style to your direct ventfireplaceandcomeswitheasyto follow instructions for installation WALL MOUNTED THERMOSTAT CONTROL KIT GWMT1 Not Sh...

Страница 37: ...For all models Allows the heater to be turned on and off conveniently RECEIVER AND HAND HELD THERMOSTAT REMOTE CONTROL KIT GHRCT SERIES Allows the fireplace to be operated in a manually or thermostati...

Страница 38: ..._______________________________________ _______________________________________________________________________________________________ ________________________________________________________________...

Страница 39: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 40: ...pairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRES...

Отзывы: