IMPORTANT: 

 The glass must be allowed to warm slowly 

and evenly.  The tempered glass will withstand a gradual 
temperature rise to 550 degrees Fahrenheit, which is more 
than a normal fire will generate.  Such materials as pitch/wax 
laden logs, very dry mill end lumber, and large amounts of 
paper or cardboard boxes can create an excessively hot fire 
and should not be burned in this fireplace.  Always keep the 
fire well back from the doors and never allow flames to 
contact the glass. 

 
CLEANING THE GLASS: 

Clean the glass with any 

commercial glass cleaner or soap and water.  DO NOT 
use any abrasive material to clean the glass.  DO NOT 
clean the glass with any cool water if the glass is still hot 
from the fire.  
 

OPTIONAL GAS LINE INSTALLATION 

GAS LINE HOOK UP SHOULD BE DONE BY YOUR 
SUPPLIER OR A QUALIFIED SERVICE PERSON. 

NOTE:

  BEFORE YOU PROCEED, MAKE SURE YOUR 

GAS SUPPLY IS TURNED OFF. 
A gas line may be installed for the purpose of installing a 
vented or vent-free gas appliance available through your local 
distributor.  Use only ½ inch black iron pipe and appropriate 
fittings.  When installing a gas line, a shut-off valve designed 
for installation outside the appliance is recommended. 

STEP 1:

 To install, remove the knockout indentation on the 

refractory, (or firebrick), wall located approximately 2 inches 
above the refractory hearth floor.  The knockout indentation 
must be firmly tapped with any solid object until it is released.  
Remove fragmented portions of refractory (see figure 22). 

 
STEP 2:

 Remove gas line cover plate on rear of fireplace and 

pull out insulation from gas line conduit sleeve.  Save 
insulation for reuse. 

STEP 3:

 Run a ½ inch black iron gas line into the fireplace 

through the gas line conduit sleeve.  Provide sufficient gas line 
into fireplace chamber for fitting connection (see figure 23). 

NOTE:

  Secure incoming gas line to wood framing to provide 

rigidity for threaded end. 

 
 
 

STEP 4:

 Repack insulation around gas line and into sleeve 

opening.  Seal any gaps between gas line and refractory 
knockout hole with refractory cement or commercial furnace 
cement.  Install the gas appliance or cap-off gas line if desired. 
 

The gas pipe is intended for connection to an unvented (vent-
free) or a decorative gas appliance (vented gas log). 
 
 
 
 
 
 
 
 
 
 
 
If you wish to install an unvented (vent-free) gas log set, ONLY 
UNVENTED GAS LOG SETS WHICH HAVE BEEN FOUND 
TO COMPLY WITH THE STANDARD FOR UNVENTED 
ROOM HEATERS, ANSI Z21.11.2, ARE TO BE INSTALLED 
IN THIS FIREPLACE. 
 

NOTE: A DESA hood must be installed when using an 
unvented gas log set 

(see accessories on page 10)

 
 
 
 
 

 
If you install a decorative gas appliance (vented gas log), the 
decorative gas appliance must comply with the 

Standard for 

Decorative Gas Appliances for Installation in solid fuel 
burning Fireplaces, ANS Z21.60-1996, Z21.84 or RGA 2-72

and shall also be installed in accordance with the 

National 

Fuel Gas code, ANS Z223.1-1996. 
 

 
 
 
 
 
 
  

 
 
 
 

 

 
 
 
 
 
 
 
 
 
 

Figure 23 

 
 
 
 
 
 
 
 
 
 

Figure 22 

CAUTION:

All gas piping and connections must be tested 

for leaks after the installation is completed.  After ensuring 
that the gas valve is on, apply a soap and water solution to 
all connections and joints.  Bubbles forming show a leak. 
Correct all leaks at once.  DO NOT USE AN OPEN 
FLAME FOR LEAK TESTING AND DO NOT 
OPERATE ANY APPLIANCE IF A LEAK IS 
DETECTED. 

WARNING:

DO NOT OPERATE AN UNVENTED 

GAS LOG SET IN THIS FIREPLACE WITH THE 
CHIMNEY REMOVED. 

WARNING:

 WHEN USING A DECORATIVE 

VENTED GAS LOG, THE DAMPER MUST BE 
REMOVED OR PERMANENTLY LOCKED IN THE 
FULLY OPENED POSITION. 

WARNING:

If the fireplace has been used for wood 

burning, the firebox and chimney must be cleaned of 
soot, creosote and ashes by a qualified chimney cleaner. 
Creosote will ignite if highly heated. 

WARNING:

 Fireplaces equipped with glass doors should 

be operated only with door fully opened or doors fully 
closed.  Doors, if left partly open, may draw gas and flame 
out of the fireplace opening creating risks of both fire and 
smoke. 

Содержание Baja II 36WIL

Страница 1: ...pproved to ANS Z21 60 Z21 84 or RGA 2 72 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard A DESA hood must be installed when using a vent free gas log heater see Accessories p 10 WARNING ALWAYS LEAVE GLASS DOORS FULLY OPENED OR FULLY CLOSED WHEN OPERATING THIS FIREPLACE SAVE THIS BOOK This book is valuable In addition to instructing you on how to install and m...

Страница 2: ...5 HEARTH EXTENSION PG 3 6 OUTSIDE AIR KIT INSTALLATION PG 4 7 FAN KIT ASSEMBLY PG 4 8 CHIMNEY PIPE INSTALLATION PG 4 5 6 9 TERMINATIONS PG 6 10 FINISHING YOUR FIREPLACE PG 7 11 MANTELS PG 7 12 GLASS DOORS PG 7 13 GAS LINE INSTALLATIONS PG 8 14 CHIMNEY OFFSET PG 9 15 DAMPER OPERATION PG 10 16 TECHNICAL SERVICE PG 10 17 REPLACEMENT PARTS AND ACCESORIES PG 11 ...

Страница 3: ...arances see page 7 Finishing your Fireplace Chimney Outer Pipe Surfaces 1 Min WARNING DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR OTHER MATERIALS MINIMUM MAXIMUM CHIMNEY HEIGHT The MINIMUM height of the chimney measured from the base of the fireplace to the flue gas outlet of the termination is 11 5 feet for straight flue or a flue with one elbow set The maximum distance between elbows is 2...

Страница 4: ...r of non combustible inorganic material having a thermal conductivity of K 0 84 BTU IN FT HR F or less at 1 thick For example if the material selected has a K factor of 0 25 such as glass fiber the following formula would apply 0 25 0 84 x 1 0 0 30 thickness required Thermal conductivity K of materials can be obtained from the manufacturer or supplier of the non combustible material If the hearth ...

Страница 5: ... flue pipe section with the hemmed end up Press down on each pipe section until the lances securely engage the hem on the fireplace starter The wire will assure the proper spacing between the inner and outer pipe sections Continue to assemble chimney sections as outlined above making sure that both the inner and outer pipe sections are locked together When installing double wall snap lock chimney ...

Страница 6: ...hich the pipe will penetrate the roof STEP 2 Determine the center point of the roof Pitch is the distance the floor drops over a given span usually 12 inches A 6 12 pitch means that the roof drops 6 inches for each 12 inches one measure horizontally down the roof STEP 3 Use the roof opening chart figure 13 below to determine the correct opening length and flashing required STEP 4 Remove the shingl...

Страница 7: ... any case refer to the installation instructions supplied with the termination The terminations approved for this fireplace are the RT 8DM and RTL 8DM that can be used for flashing or chase and ET 8DM ETO 8DM ETL 8DM and ETLO 8DM for chase style termination only Figure 16 shows an RTL 8DM round top termination Terminations with 16 slip pipe sections are available The RTT 8DM and RTTL 8DM are appro...

Страница 8: ... the fireplace The clearances from the side of the fireplace to any combustible material and wall should fall within the limits shown in figure 20 Example 1 figure 20 The face of a mantel bookshelf etc is made of combustible materials and protrudes 2 from the wall the fireplace is installed in This combustible material must be a minimum of 4 from the side of the fireplace opening Example 2 figure ...

Страница 9: ... gas line to wood framing to provide rigidity for threaded end STEP 4 Repack insulation around gas line and into sleeve opening Seal any gaps between gas line and refractory knockout hole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired The gas pipe is intended for connection to an unvented vent free or a decorative gas appliance vented g...

Страница 10: ...to lock it in place see figure 24 FOR FURTHER OPERATING GUIDELINES INSTRUCTIONS AND WARRANTY INFORMATION PLEASE REFER TO YOUR HOMEOWNERS GUIDE OR CONTACT YOUR AUTHORIZED DEALER TECHNICAL SERVICE You may have further questions about installation operations or troubleshooting If so contact The Technical Service Department at 1 888 427 8322 When calling have the model number of the fireplace ready Fi...

Страница 11: ...For more information visit www desatech com 10 REPLACEMENT PARTS ACCESSORY PARTS ...

Отзывы: