Page 16 • MNFL003 ║ Issue/Rev. 0.1 (9/13)
17933 (460D) 712
Comm 2 Mode
17934 (460E) 718
Comm 3 Mode
Directory: COMM_PORT_DIR
Data Type: UNSIGNED_INTEGER
Start Address: 18048
18048 (4680) 705
Comm 1 Timeout
18049 (4681) 711
Comm 2 Timeout
18050 (4682) 717
Comm 3 Timeout
18051 (4683) 726
Ethernet Host Timeout
Directory: INJ_DIR
Data Type: FLOAT
Start Address: 19200
19200 (4B00) 831
Metered Inj K Factor
19202 (4B02) 832
Metered Inj Meter Fac
19204 (4B04) 833
Metered Inj High Tol
19206 (4B06) 834
Metered Inj Low Tol
Directory: INJ_DIR
Data Type: UNSIGNED_CHAR
Start Address: 19968
19968 (4E00) 801
Additive Injector 1 Type
19969 (4E01) 802
Additive Injector 2 Type
19970 (4E02) 803
Additive Injector 3 Type
19971 (4E03) 804
Additive Injector 4 Type
19972 (4E04) 835
Metered Inj Max Tol Err
Directory: INJ_DIR
Data Type: UNSIGNED_INTEGER
Start Address: 20096
20096 (4E80) 841
Add Injector 1 Address
20097 (4E81) 842
Add Injector 2 Address
20098 (4E82) 843
Add Injector 3 Address
20099 (4E83) 844
Add Injector 4 Address
Directory: LOAD_ARM_DIR
Data Type: TEXT
Start Address: 20480
20480 (5000) 121
Position ID
20496 (5010) 152
Permissive 1 Message
20512 (5020) 154
Permissive 2 Message
20528 (5030) 733
Report Print Time
Directory: LOAD_ARM_DIR
Data Type: FLOAT
Start Address: 21248
21248 (5300) 202
Low Flow Start Rate
21250 (5302) 203
Low Flow Start Amount
21252 (5304) 204
Low Flow Start % of Batch
21254 (5306) 223
Overrun Alarm Limit
Directory: LOAD_ARM_DIR
Data Type: UNSIGNED_CHAR
Start Address: 22016
22016 (5600) 151
Permissive 1 Sense
22017 (5601) 153
Permissive 2 Sense
22018 (5602) 231
Zero Flow Timer
22019 (5603) 232
Valve Fault Timeout
22020 (5604) 731
Report Select
22021 (5605) 732
Report Total Resolution
22022 (5606) 736
Batch Reset on Report
Directory: LOAD_ARM_DIR
Data Type: UNSIGNED_INTEGER
Start Address: 22144
22144 (5680) 734
Report Interval
Directory: METER_DIR
Data Type: FLOATING POINT
Start Address: 23296
23296 (5B00) 306
DP Flow Rate Cutoff
23298 (5B02) 363
SMASS Coefficient Ka
23300 (5B04) 364
SMASS Coefficient Kb
23302 (5B06) 365
SMASS Coefficient Kc
Directory: METER_DIR
Data Type: DOUBLE
Start Address: 23552
23552 (5C00) 301
K Factor
Directory: METER_DIR
Data Type: UNSIGNED_CHAR
Start Address: 24064
24064 (5E00) 201
Valve Type
24065 (5E01) 305
Dual Pulse Error Reset
24066 (5E02) 307
Pulse Security Alarm Amount
24067 (5E03) 308
Pulse Period Sample Count
24068 (5E04) 361
Mass Meter Type
24069 (5E05) 367
Mass Meter Pulse Multiplier
24070 (5E06) 368
Mass Meter Low Flow Cutoff
24071 (5E07) 369
Mass Meter Tube Material
24072 (5E08) 370
Mass Meter Model
24073 (5E09) 309
Pulse Multiplier
24074 (5E0A) 331
Ultrasonic Meter Type
24075 (5E0B) 332
Share Temp. w/Meter
24076 (5E0C) 333
Share Press. w/Meter
microFlow.net Liquid Modbus Communications Manual
Modbus Register Reference