Page 14 • MNFL003 ║ Issue/Rev. 0.1 (9/13)
Directory: SYSTEM_DIR
Data Type: FLOATING POINT
Start Address: 6912
6912 (1B00) 102
Pulse Out 1 Pulses/Amount
6914 (1B02) 104
Pulse Out 1 Max Frequency
6916 (1B04) 402
Reference Temperature
6918 (1B06) 814
Inject to Totals Convert
Directory: SYSTEM_DIR
Data Type: UNSIGNED_CHAR
Start Address: 7680
7680 (1E00) 101
Pulse Output Function
7681 (1E01) 103
Pulse Output Units
7682 (1E02) 111
Flow Rate Time
7683 (1E03) 113
Volume Units
7684 (1E04) 115
Mass Units
7685 (1E05) 122
Run Display Options
7686 (1E06) 123
Display Resolution
7687 (1E07) 124
Decimal/Comma Select
7688 (1E08) 125
Default/Translated Literals
7689 (1E09) 131
Dynamic Display Timeout
7690 (1E0A) 132
Auto Reset Time
7691 (1E0B) 141
Batch Reset Enable
7692 (1E0C) 302
Pulse In Type
7693 (1E0D) 303
Channel Select
7694 (1E0E) 401
Temperature Units
7695 (1E0F) 411
Density Units
7696 (1E10) 501
Pressure Units
7697 (1E11) 601
Driver Alarm Clearing
7698 (1E12) 602
Powerfail Alarm
7699 (1E13) 725
Comm Link Programming
7700 (1E14) 811
Add Injector Pacing Units
7701 (1E15) 821
Add Injector Stop Option
7702 (1E16) 724
Ethernet Host Control
7703 (1E17) 727
Modbus Endian Select
7704 (1E18) 735
User Text Archived
7705 (1E19) 142
Sampler Type
7706 (1E1A) 143
Sampler Pace
7707 (1E1B) 144
Sampler Pulse Width
7708 (1E1C) 145
Sampler Disable
------------------------------------------------------------------------
Program Configuration, etc. - HOLDING REGISTERS
- Function 3,6,16 table:
-----------------------------------------------------------
Dec. Hex. Parameter # and Description
Directory: DIGITAL_DIR
Data Type: UNSIGNED_CHAR
Start Address: 3584
3584 (0E00) 201
Input 1 (DC) Function Select
3585 (0E01) 202
Input 2 (DC) Function Select
3586 (0E02) 203
Input 3 (DC) Function Select
3587 (0E03) 301
Output 1 (DC) Function Select
3588 (0E04) 302
Output 2 (DC) Function Select
3589 (0E05) 303
Output 3 (AC) Function Select
3590 (0E06) 304
Output 4 (AC) Function Select
3591 (0E07) 305
Output 5 (AC) Function Select
3592 (0E08) 306
Output 6 (AC) Function Select
Directory: ANALOG_DIR
Data Type: FLOATING POINT
Start Address: 4864
4864 (1300) 402
Analog I/O 1 RTD Offset
4866 (1302) 412
Analog I/O 2 (4-20ma) Low
Value
4868 (1304) 413
Analog I/O 2 (4-20ma) High
Value
Directory: ANALOG_DIR
Data Type: UNSIGNED_CHAR
Start Address: 5632
5632 (1600) 401
RTD Function
5633 (1601) 411
4-20 ma Function
Directory: SYSTEM_DIR
Data Type: TEXT
Start Address: 6144
6144 (1800) 101
Date{O}
6160 (1810) 102
Time{O}
6176 (1820) 112
Flow Rate Descriptor
6192 (1830) 114
Volume Descriptor
6208 (1840) 116
Mass Descriptor
6224 (1850) 691
User Alarm 1 Message
6240 (1860) 692
User Alarm 2 Message
6256 (1870) 693
User Alarm 3 Message
6272 (1880) 694
User Alarm 4 Message
6288 (1890) 695
User Alarm 5 Message
6304 (18A0) 812
Additive Units Descriptor
6320 (18B0) 813
Additive Totals Units
microFlow.net Liquid Modbus Communications Manual
Modbus Register Reference