Switching connection from three-phase 400 Vac to single-phase 230 Vac
Remove the back cover of the oven.
Disconnect the phases S y R from the connection terminals.
Connect the bridges supplied together with this manual as described.
Switching connection from three-phase 400 Vac to three-phase 230 Vac
Remove the back cover of the oven.
Disconnect phase R from the connection terminals.
Connect the bridges supplied together with this manual as described.
5.2 Vapour exhaust from the cooking chamber
Exhaust gases may be wet and reach high temperatures. Do not use tubes made of materials not ensuring absolute
thermal stability up to 250ºC to channel exhaust gases.
A condenser enabling the condensation of vapours and exhaust of those vapours into a drainage may be adapted
to treat baking vapours.
Important
: Do not channel the vapour exhaust from the baking chamber more than 2 meters due to risk of
condensation. Besides, it could affect its uniformity.