TROUBLE-SHOOTING CHART
26
Fluid Management
®
Paint mixer will not shut
off.
timer control on the front control
panel.
• Replace if necessary.
if relay is stuck in the closed posi-
tion.
for bad timer .
• Replace relay.
• Replace timer.
May be problem with printed circuit
board.
• Call Customer Service.
• Replace printed circuit
board.
The shake motor has volt-
age and hums, but it will
not run.
for low line voltage.
• Confirm that the mixer is
on a dedicated line.
V-belt tension.
• Correct tension.
motor capacitor.
• Replace motor capacitor.
shake motor.
• Replace shake motor.
An excessive amount of
vibration occurs.
if mixer is out of balance.
• Level by adjusting the
legs.
if adjustable leg is broken or dam-
aged.
• Replace adjustable leg.
for broken strut.
• Replace broken strut.
The START light is on and
nothing happens.
if the DC motor coupling set screw
is loose.
• Tighten the DC motor
coupling set screw.
for broken wire in the DC motor
cabling.
• Replace DC motor cable.
for problem with the DC motor.
• Replace DC motor.
for problem with printed circuit
board.
• Call Customer Service.
Replace printed circuit
board.