37
7.12.3 Failsafe
For failsafe function, PL18 paladin transmitter provides the
following three settings:
• Set to disable the signal output of i-BUS-out and PPM
protocol interfaces in case of out-of-control, i.e., no output
at i-BUS-out & PPM interfaces in case of losing control.
• Set failsafe values channel by channel: No output/Fixed
value/Hold.
• New Added item: Set Failsafe for all channels set to fixed
values. With this function, With this function, you can set the
output values of all channels controlled by a control to the
current value, and this value will be output when the system
is losing control.
Classic receiver:
• For CH1, you can select PPM/PWM only. If the receiver does not
support PPM signal output, the setting is invalid.
•
For receivers with SENS interfaces, i-BUS/Servo does not
support i-BUS-IN.
Note: New [No Output] function for 1.0.55 and higher versions.
Tap to turn on or off this function.
Tap to enter the the setting interfae of the corresponding channel.
Set i-BUS-out & PPM to no output
This item is for i-BUS and PPM signals. After the
Set i-BUS-out
&PPM to no output
is enabled, regardless of the setting of
the failsafe, these two types of failsafe signals are always no
output. If the function isdisabled, after losing control, you
can set by channel: set to fixed value or keep the last output
value.By default, the system is in the enabled status.
Function setup:
If the check box next to right of the option is not ticked (
√
),
it indicates that the function is disabled.
Note: When Set i-BUS-OUT&PPM signal to no output is not checked and
the channel is set to no output, the last value is output in case of out-of-
control.
Channel 1~Channel 18
Can be used to set the output signal states of channels 1~18
respectively: No output means the PWM channel interface
is no output in case of out-of-control; Hold means the last
channel value is kept in case of losing control; Fixed value
means the configured channel value is output in case of out-
of-control.
Function setup:
1. Tap to select the channel to be set and enter the next