Operation instructions
●
Make this sequence using the U/D switch: 2 click in the
UP position, 2 click in the DOWN position and 1 click in
UP; if the sequence is correct the EFC-P enters in
positions programming mode and the LED2/LED3 briefly
flash.
●
Now the first led is flashing indicating that you can adjust
the flaps in the desired position (using the U/D switch).
To store the position, briefly move the A/M switch in
“Manual” and then return in “Automatic”.
●
Now the second led is flashing and you can adjust and
then store the second position in the same way explained
in the previous step (U/D switch to adjust then A/M
switch to store the position). Repeat again the step for
the third and fourth position.The EFCX will automatically
exit from the programming mode and become operative
once the last position is correctly stored in memory.
NOTE:
If the EFCX is powered on the first time without enter
in the programming mode the four LED will simultaneously
flash.
The positions remains stored in memory also without
power supply.