![Flybox EFC-P Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/flybox/efc-p/efc-p_installation-and-user-manual_2311263018.webp)
FLYBOX
EFC57-P/EFC-P
- User’s manual -
Installation and User
Manual, Safety Instructions and Warning Booklet
8
Rev. 3.4
®
Electrical installation
1 – Motor out (-)
2 – Power input (+12V)
3 - Positive voltage (+5V) for the position's transducer
4 – Position's transducer signal
5 – Ground for the position's transducer
6 – Motor out (+)
7 – Power input (GND)
8 – “DOWN” limit switch
9 – Limit switches common connection
10 – “UP” limit switch
NOTE:
Insert a breaker to the power lead (+12V);
choose a correct amperage depending on the actuator
installed.
CAUTION:
Voltage peaks higher than 15 Volt on the
supply line can damage the device.
Connector pinout:
NOTE:
It’s recommendend to use shielded cable (2
poles+shield) for the motor output (pin#1 & 6),
connecting the shield of the cable to ground on the
EFCX side and leaves disconnected the shield on the
actuator side.
CAUTION:
The EFCX must be turned off in case of start
with booster. Open the corresponding breaker before
starting.
NOTE:
Use aeronautical standard wire and cable.