Attachment Ex-protection Information for Drum and Container Pumps
ENGLI
SH
3
Transport
Information on transport in an ex-protected area:
> Prevent electrostatic charge build-up during transport.
> Observe internal operating instructions.
4
Commissioning in explosive environments
Attention!
Observe the EC type examination certificate and the certificate
of conformity, respectively.
The pump
types F … must not be used as a stationary unit in
hazardous locations and must be continuously supervised.
The pump types FP … Ex S can be used as a stationary unit
in hazardous locations but must nevertheless be continuously
supervised.
Explosion hazard!
For use in hazardous locations only use explosion-proof electric
motors which are approved for category 2 (ZONE 1) or com-
pressed air motors.
For transferring liquids of explosion groups IIA and IIB and tem-
perature class T1 to T4, only pumps which are certified for use
in category 1 (ZONE 0) must be used.
If the commutator motors are operated together with the pump,
comprehensive, clear equipotential bonding is essential
(earthing).
For equipotential bonding, an electrically conductive connection
must be produced between the motor and the pump according
to EN 60079-14.
The drum pump must be arranged in a way to avoid friction and
impact sparks and to allow safe operation.
Repair on explosion-proof motors or pumps may only be carried
out by the manufacturer or an authorized repair shop.
When mixing non-conductive liquids, there is a risk of the circu-
lated liquid becoming electrostatically charged. Make sure to
prevent any ignition hazards.
The ex-protected motor must be located outside the mobile
container.
The hose used must be sufficiently conductive (see TRbF 50
annex B).
Observe the Technical Guidelines for "Flammable Liquids"
(TRbF) and the explosion protection guidelines of the Employ-
er's Liability Insurance Association of the Chemical Industry
(BG Chemie) during installation and operation.
Fire hazard!
For transferring of liquids of explosion groups IIA and IIB and
temperature class T1 to T4, only pumps which are certified for
use in category 1 (ZONE 0) must be used