22
TS52PRO Test Set
Users Guide
Specifications
Electrical
Current Range
(Off-Hook)
10 mA to 100 mA
DC Resistance
Off-Hook
150
nominal
On-Hook
>3 M
AC Impedance
Off-Hook
600
nominal; 300 Hz to
3400 Hz
On-Hook
>120 k
; 300 Hz to 3400 Hz
Rotary Dial Output
Pulsing Rate
10 pps ±1 pps
Break/Make Ratio
60/40
Interdigit Interval
>300 ms
Resistance During
Break
>100 k
DTMF Output
Tone Frequency
Error
±1.5 % maximum
Tone Level
-3 dBm combined (typical)
High versus Low
Tone Difference
2 dB ± 2 dB
Memory Dialing
Memory Capacity
10 speed dial memories plus
one last number redial
memory
Digit Capacity
23 digits per memory
PBX Pause
Duration
4 seconds
Hook Flash
Duration
User programmable; default
of 600 ms
Automatic Speaker
Shut Off Duration
User programmable; default
of 2 minutes
Battery
9 V alkaline battery
Physical
Measurement
10 in x 3.75 in x 4.25 in
(254 mm x 96 mm x 107 mm)
Weight
Less than 1.5 pounds (0.68 kg)
with one belt clip
Water Resistance
Designed to be rain and
moisture resistant
Environmental
Temperature
Range
Handset speech
and dialing
functions
-22°F to 140 °F (-30°C to 60°C)
LCD function
-13°F to 140°F (-25°C to 60°C)
Storage
-22°F to 150°F (-30°C to 66°C)
Altitude
To 10,000 ft. (3,000 m) max
Relative Humidity
95% to 30°C
75% to 40°C
45% to 50°C
30% to 60°C
Safety
Regulatory
Compliance
Complies with IEC 61010-1,
300 Vdc maximum, Pollution
Degree 2
Maximum
Transient Voltage
1500 Vpk
EMC
Complies with EMC EN61326-
1, Portable. Meets FCC CFR
Title 47, Part 15, Subpart B.
Note