![Fluke TS52PRO Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/fluke/ts52pro/ts52pro_user-manual_2310027024.webp)
20
TS52PRO Test Set
Users Guide
bfp07.eps
Figure 7. Removal/Installation of Plastic Clip
Installing a New Line Cord
To install a new line cord:
1
From the outside of the housing, slide the screw
lugs of a new line cord through the hole in the
end of the test set housing. Make sure the crimp
barrel offset side of the screw lugs is up (Figure 9)
and that the line cord screw lugs are flush against
the circuit board.
Note
Do not over tighten screws. Over tightening will
strip the plastic.
2
Fasten the red wire lug to the PC board (Ring) with
screw and washer (Figure 8).
3
Fasten the black wire lug to the PC board (Tip)
with screw and washer (Figure 8).
4
Insert the plastic clip over the line cord strain relief
at the base of the test set housing (Figure 7) and
press tightly into place. Inspect all work to ensure
no pinched wires or areas where weather
resistance and safe operation is affected. Reinstall
the battery. Observe the proper polarity.
5
Place the battery door cover on the test set and
fasten the four screws (Figure 4). Tighten screws to
a maximum torque of 0.904 N-m or 8 in-lb.
bfp08.eps
Figure 8. Removal/Installation of Line Cord
Screw Lugs
bfp09.eps
Figure 9. Orientation of Line Cord Screw Lugs
Screw Lug
Note:
Speaker not
shown for
illustration
purposes.
Red line cord