Oscilloscope modes

190-062

190-102

190-202

190-502

190-104

190-204

Vertical deflection

Number of channels

2

2

2

2

4

4

Bandwidth

60 MHz

100 MHz

200 MHz

500 MHz

100 MHz

200 MHz

Rise time

5.8 ns

3.5 ns

1.7 ns

0.7 ns

3.5 ns

1.7 ns

Number of scope inputs

2 input channels plus external trigger

4 input channels

Channel architecture

All inputs fully insulated from each other and from ground 

Inputs may be activated in any combination

Input coupling

AC or DC, with ground level indicator

Input sensitivity

2 mV/div to 100 V/div, plus variable attenuation

Bandwidth limiter

User selectable: 20 kHz, 20 MHz or full bandwidth

Normal/invert/variable

On each input channel, switched separately

Input voltage

CAT III 1000 V/CAT IV 600 V rated, see General Specifications for further details

Vertical resolution

8 bit 

Accuracy

± (2.1 % of r 0.04 x range/div) @ 5 mV/div to 100 V/div

Input impedance

1 MΩ ± 1 % // 14 pF ± 2 pF

Horizontal

Maximum real-time sample 

rate (sampled simultaneously)

625 MS/s for 

each channel

1.25 GS/s for 

each channel

2.5 GS/s (2ch)

5 GS/s (single 

channel) or 2.5 

GS/s (on 2ch)

1.25 GS/s for 

each channel

2.5 GS/s (2ch)  

1.25 GS/s (4ch)

Record length

Up to 10,000 samples per channel

Time base range

10 ns/div  

to 4 s/div

5 ns/div  

to 4 s/div

2 ns/div  

to 4 s/div

1 ns/div.  

to 4 s/div.

5 ns/div  

to 4 s/div

2 ns/div  

to 4 s/div

Time base in a 1-2-4-sequence 

Slower time/division settings using ScopeRecord

 Roll mode (see ‘Recorder mode’)

Maximum record length

10,000 samples per channel in scope mode;  

30,000 points per channel in ScopeRecord

 Roll mode (see ‘Recorder mode’)

Timing accuracy

± (0.01 % of r 1 pixel)

Glitch capture

8 ns peak detect on each channel  

(using real time sampling and data compression, at any timebase setting)

Display and acquisition

Display

153 mm (6 in) full-color LCD with LED backlight

Display modes

Any combination of channels; average on/off; replay

Visible screen width

12 divisions horizontally in scope mode

Digital persistence modes

off/short/medium/long/infinite and envelope mode

Waveform mathematics

One mathematical operation on any 2 input channels: add/subtract/multiply; X-Y-mode 

Frequency Spectrum using FFT analysis

Acquisition modes

Normal, Averaged, Auto, Single Shot, ScopeRecord™ roll, glitch capture,  

waveform compare with automatic “Pass/Fail testing”; Replay

Trigger and delay

Source

Input A, B or External (via meter input)

Input A, B, C or D

Modes

Automatic Connect-and-View

, free run, single shot, edge, delay, dual slope,  

video, video line, selectable pulsewidth (channel A only), N-cycle

Connect-and-View

Advanced automatic triggering that recognizes signal patterns, automatically sets up and continuously adjusts 

triggering, time base and amplitude. Automatically displays stable waveforms of complex and dynamic signals 

like motor drive and control signals. Can be switched off if preferred.

Video triggering (on ch. A)

NTSC, PAL, PAL+, SECAM; Includes field 1, field 2 and line select

High-res, non-interlaced video Non-interlaced video with line-select, for line frequencies in the range 14 kHz up to 65 kHz
Pulse width triggering 

(on channel A)

Pulse width qualified by time 

Allows for triggering <t, >t, =t, ≠ t, where t is selectable in minimum steps of 0.01 div or 50 ns

Time delay

1 full screen of pre-trigger view or up to 100 screens (=1,200 divisions) of post-trigger delay

Dual slope triggering

Triggers on both rising and falling edges alike

N-cycle triggering

Triggers on N-th occurrence of a trigger event; N to be set in the range 2 to 99

Shop for Fluke products online at:

1.877.766.5412

www.

MyFlukeStore

.com

Содержание ScopeMeter 190-062

Страница 1: ...nect and View triggering for intelligent automatic triggering on fast slow and even complex signals Frequency Spectrum using FFT analysis Automatic capture and REPLAY of 100 screens ScopeRecord Roll mode gives 30 000 points per input channel for low frequency signal analysis TrendPlot paperless recorder mode with deep memory for long term automatic measurements 5 000 count DMM included in the 2 ch...

Страница 2: ... 8 ns peak detect on each channel using real time sampling and data compression at any timebase setting Display and acquisition Display 153 mm 6 in full color LCD with LED backlight Display modes Any combination of channels average on off replay Visible screen width 12 divisions horizontally in scope mode Digital persistence modes off short medium long infinite and envelope mode Waveform mathemati...

Страница 3: ...ss Fail Testing In waveform compare mode the oscilloscope can be set up to store only matching Pass or only non matching Fail acquired waveforms in the replay memory bank for further analysis Automatic scope measurements V dc V ac rms V ac dc Vpeak max Vpeak min Vpeak to peak A ac A dc A ac dc frequency in Hz risetime using cursors falltime using cursors Power Factor PF Watts VA VA reactive phase ...

Страница 4: ...28 C Voltage V dc accuracy 0 5 5 counts 1 5 5 counts V ac true rms accuracy 1 10 counts 2 5 15 counts 15 Hz to 60 Hz 1 5 10 counts 60 Hz to 1 kHz 60 Hz to 20 kHz 2 5 15 counts V ac dc true rms accuracy 1 10 counts 2 5 15 counts 15 Hz to 60 Hz 1 5 10 counts 60 Hz to 1 kHz 60 Hz to 20 kHz 2 5 15 counts Voltmeter ranges 500 mV 5 V 50 V 500 V 1 000 V Resistance Ranges 500 Ω 5 kΩ 50 kΩ 500 kΩ 5 MΩ 30 M...

Страница 5: ...imespan 6 sec 48 hr Time division in view all mode 0 5 s div 4 h div Glitch capture 8 ns Sample rate 125 MS s Resolution 200 μsec 4 8 sec Trendplot Recording Multiple channel electronic paperless recorder Graphically plots displays and stores results of up to four automatic scope measurements or a DMM reading over time Source and display Any combination of scope measurements made on any of the inp...

Страница 6: ...vides date and time stamp information for ScopeRecord for 100 Screen Replay sequences and for TrendPlot recordings Case Design Rugged shock proof with integrated protective holster Handstrap and hangstrap included as standard Kensington lock supported to lock down instrument when left unattended Drip and dust proof IP 51 according to IEC529 Shock and vibration Shock 30 g vibration sinusoidal 3 g a...

Страница 7: ...l and data transfer under PC control Probe calibration output Dedicated probe cal output with reference contact provided fully insulated from any measurement input channel Warranty Three years parts and labor on main instrument one year on accessories Included accessories Battery charger mains adapter BC190 Li Ion battery pack BP290 2400 mAh BP291 4800 mAh Voltage probe sets Each set includes grou...

Страница 8: ...nic Voltage Probe set 10 1 500 MHz one set green VPS410 R Industrial Voltage Probe set 10 1 one set red VPS410 G Industrial Voltage Probe set 10 1 one set grey VPS410 B Industrial Voltage Probe set 10 1 one set blue VPS410 V Industrial Voltage Probe set 10 1 one set green VPS420 R High working voltage ruggedized probe set 100 1 150 MHz bicolored red black SW90W FlukeView ScopeMeter Software packag...

Отзывы: