4
Frequency output - VIB 6.172 / VIB 6.210
5 dB
0
-5 dB
-10 dB
0.1 Hz 1 Hz
10 Hz 100Hz 1kHz 10kHz 100 kHz
Technical Data
PARAMETER
VIB 6.172
VIB 6.210
Measur
ement
Signaling system
Voltage output according to IEPE standard
Transmission factor
± 4% 100 mV/g (ref.: 159 Hz; 25 °C)
Frequency range
± 3dB 0.1 Hz ... 10 kHz
Resonant frequency
17 kHz; > 10 dB damped
15 kHz; > 10 dB damped
Linearity range
< 70 g (r.m.s.) ± 1%
Temperature range
-40 °C ... +120 °C
-40 °C ... +85 °C
Electrical
Power requirements
2 - 10 mA / 18 - 30 V DC
Bias, DC output
12 V DC
Grounding
insulated from machine ground, internal shielding
Transverse sensitivity
< 5%
Temperature sensitivity
< 0.07% of measurement / K (ref.: 25°C)
Magnetic field sensitivity
< 0.1 g/T (at 50 Hz)
Base strain sensitivity
< 0.1 mg/µm/m
Electrical noise (r.m.s)
< 1.0 mg (0.1 Hz - 10 kHz)
< 1.5 mg (0.1 Hz - 10 kHz)
Output impedance
< 10 Ohm
< 100 Ohm
Mechanical
Case material
Stainless steel VA 1.4305
Environmental protection
IP 67 (with connected cable)
Shock limit
5000 g
Connector type
Cable connector, 2-pole (MIL-C-5015) M12 Cable connector, 4-pole
Weight
85 g
72 g
Mounting on measuring point
M8 thread bolt (changeable);
mounting adapter optional
M8 thread bolt (fixed);
mounting adapter optional