Accelerometer (100mV/g) 

VIB 6.172, VIB 6.210

Installation and Operation

Содержание PRUFTECHNIK VIB 6.172

Страница 1: ...Accelerometer 100mV g VIB 6 172 VIB 6 210 Installation and Operation ...

Страница 2: ...mity is available at www pruftechnik com Repair and Maintenance The operation of the accelerometer is mainte nance free A repair is not possible Disposal Dispose of the accelerometer after use in accor dance with applicable national regulations Mounting The frequency response and dynamic range of an accelerometer can be greatly influenced by the installation Poor coupling to the measurement locati...

Страница 3: ...nding position Leave enough space around the adapter in order to apply the bonding compound Flattening and roughening Sand down any paint on the mounting surface to bare metal Ø 30 mm Level out the mounting surface if necessary Roughen the mounting surface with a file filing a few grooves in a diamond pattern provides great er adhesion Optional and only if drilling at the mounting lo cation is pos...

Страница 4: ... output 12 V DC Grounding insulated from machine ground internal shielding Transverse sensitivity 5 Temperature sensitivity 0 07 of measurement K ref 25 C Magnetic field sensitivity 0 1g T at 50 Hz Base strain sensitivity 0 1mg µm m Electrical noise r m s 1 0 mg 0 1 Hz 10 kHz 1 5 mg 0 1 Hz 10 kHz Output impedance 10 Ohm 100 Ohm Mechanical Case material Stainless steel VA 1 4305 Environmental prote...

Страница 5: ... o m e t e r T y p e V I B 6 2 1 5 S N P 0 0 0 0 5 X Installation height 68 1 Signal 2 nc 3 GND 4 nc 1 4 3 2 Pin allocation accelerometer Signal A GND B VIB 6 172 VIB 6 210 22 22 M8 M8 VIB 5 740 X VIB 5 741 X VIB 3 575 10 VIB 3 575 20 VIB 6 172 VIB 6 210 ...

Страница 6: ...ite www pruftechnik com Lay the cable Lay the cable in a cable conduit or a protective tube Use Velcro strips or cable ties for mounting Do not lay the connection cable parallel to pow er lines Keep a minimum distance 1m Lay a cable loop with sufficient excess cord at each connection or before each gland Label the cable ends to avoid confusion Observe the terminal assignments on the CMS see CMS in...

Страница 7: ...449 ICP VIB 5 438 0 5 VIB 93055 VIB 311221 10 TNC VIB 5 449 ICP VIBSCANNER VIBXPERT II VIBXPERT I VIBGUARD portable VIB 5 444 5 Mini Snap Extension cable optional Cable adapter Connection options for accelerometer VIB 6 172 to portable measurement devices ...

Страница 8: ...Fluke Deutschland GmbH Freisinger Str 34 85737 Ismaning Germany 49 89 99616 0 www pruftechnik com Productive maintenance technology VIB 9 833 EN 08 2018 ...