Fluke OptiView III Series Скачать руководство пользователя страница 5

i

Table of Content

s

Title

 Page

Before You Start ............................................................................................................................ 1

Safety Information  ................................................................................................................. 1
Cleaning the Analyzer   .......................................................................................................... 2
Has This Instrument Been Damaged in Shipping?  ............................................................... 2
Contacting Fluke Networks Sales, Service, and Support Centers  ........................................ 2
OptiView

TM

 Series III Workgroup Analyzer Support  ............................................................ 2

The Analyzer and Accessories ....................................................................................................... 3

Supplied Out of the Box Items  .............................................................................................. 4

About the Analyzer ....................................................................................................................... 6

General Specifications ............................................................................................................ 6
A Look at the Analyzer External Connections and LEDs  ..................................................... 6

External Connectors ........................................................................................................ 6
LEDs .................................................................................................................................. 6

Connecting to the Management Port ................................................................................... 7
Changing the SFP Adapter  .................................................................................................... 7
Security ................................................................................................................................... 8
Setting the Remote Control PC IP Address  ........................................................................... 8
Setting the Analyzer IP Address on the Network Under Test Interface  ............................. 8
Setting the Analyzer IP Address on the Management Port  ................................................ 8
Restoring the OptiView

TM

 Workgroup Analyzer Default Configuration ........................... 8

Accessing the Analyzer through the Remote User Interface Software ..................................... 8

Using the OptiView

TM

 Browser and User Interface Software .............................................. 9

Refresh analyzer list ...................................................................................................... 10
Launch user interface for selected analyzer ................................................................ 10
Launch Web browser for selected OptiView Integrated Network Analyzer  ............ 10
Update firmware for selected OptiView

TM

 Workgroup Analyzer .............................. 10

Installing the User Interface Software  ................................................................................ 10
User Interface Events that will Terminate a Remote Session  ............................................ 11

Configuring the Analyzer through the Serial Configuration Port  ........................................... 12

Configuration Port Guidelines  ..................................................................................... 12
Root mode user commands: ......................................................................................... 13
Remote mode user commands ..................................................................................... 13
Management configuration mode user commands: .................................................. 14
Network configuration mode user commands:  .......................................................... 14

Using the Online Help System  .................................................................................................... 15

Accessing and Navigating the Help System ........................................................................ 15
Accessing the Online Documentation ................................................................................. 16

Updating the OptiView Workgroup Analyzer Firmware .......................................................... 16

Содержание OptiView III Series

Страница 1: ...g Started Guide PN 3105444 February 2008 2008 Fluke Corporation All rights reserved Printed in USA All product names are trademarks of their respective companies TM Fluke Networks Optiview Workgroup A...

Страница 2: ...Networks authorized service center within the warranty period To obtain warranty service contact your nearest Fluke Networks authorized service center to obtain return authorization information then...

Страница 3: ...notice this list of conditions and the following disclaimer in the documentation and or other materials provided with the distribution THIS SOFTWARE IS PROVIDED BY THE CRYPTIX FOUNDATION LIMITED AND C...

Страница 4: ......

Страница 5: ...OptiViewTM Workgroup Analyzer Default Configuration 8 Accessing the Analyzer through the Remote User Interface Software 8 Using the OptiViewTM Browser and User Interface Software 9 Refresh analyzer l...

Страница 6: ...ep Three Run the User Interface Software 18 Troubleshooting Your Analyzer 19 Before Calling Technical Support 19 Do you suspect the analyzer has locked up 19 Unexpected IP Discovery or Tools results 1...

Страница 7: ...Look for cracked or missing plastic Pay particular attention to the insulation surrounding the connectors Do not operate the product around explosive gas vapor or dust No serviceable parts Do not try...

Страница 8: ...inspection report ALWAYS NOTIFY THE CARRIER FIRST Please do not write the factory until you have notified the carrier since this will delay the claim If this precaution is not taken we cannot assist y...

Страница 9: ...wTM Series III Worgroup Analyzer supports 10 100 1000 Ethernet through the Network 10 100 1000 port RJ 45 jack along with a 1000BASE X fiber optic port that supports the following optional fiber adapt...

Страница 10: ...cations N A CD ROM OptiViewTM Resource CD Includes user interface software OptiView firmware MIB Browser and Getting Started Guide Multiple languages in PDF format N A Female to female DB 9 null modem...

Страница 11: ...nalyzer Bundle Includes OPV RPTR PRO and OPV PE PRO OPVS3 WGA GIG DSVS 19 Rack mount Kit Rack mount kit for holding one or two OptiViewTM Workgroup Analyzers OPV RMK Hard side transit case Hard shell...

Страница 12: ...ector Indicates that link has been established on the Management connection green Flashing green indicates activity is present Power PWR Indicates whether the analyzer is Off or On blue 10 100 1000 Fi...

Страница 13: ...ts The Management Port can be used to view traffic discovered on the Network 10 100 1000 or 1000BASE X fiber ports The Management Port is also used to flash new software into the analyzer Note Analyze...

Страница 14: ...on the Network Under Test Interface The network under test interface connects either through the Network 10 100 1000 or the 1000BASE X port It does not include the Management Port To set the IP addres...

Страница 15: ...t first configure the Remote Control IP address setting This is found in the Setup Remote screen The Remote Control IP address should match the IP address of the PC that you intend to run the OptiView...

Страница 16: ...yellow triangle indicates this This button is enabled only when selecting an OptiViewTM Workgroup Analyzer through the Management Port It does not apply to OptiViewTM Integrated analyzers Note Newer O...

Страница 17: ...BASE X fiber ports and not to the Management port Auto Reconfigure on Network Change is checked in the TCP IP setup screen and the analyzer patch cable is disconnected and reconnected to another jack...

Страница 18: ...or the password will appear to gain configuration access If the analyzer is not password protected configuration access is directly available The configuration port command line interface provides fou...

Страница 19: ...the IP address A B C D of the PC that will be running the remote user interface software The analyzer will send it s identification to that PC so that the OptiView Browser will display that analyzer...

Страница 20: ...thin the Management configuration mode ipaddr A B C D E F G H ipaddr autoconfig Statically assigns the IP address A B C D and subnet mask E F G H of the Network port Address and subnet mask are entere...

Страница 21: ...he analyzer Some of the topics of interest are exit Exits the Network configuration mode Exiting will discard any Network port configuration changes unless apply is entered show user command Displays...

Страница 22: ...nd Navigating the Help System ahq47s bmp Figure 4 The Help Screen The help system is an integral part of the analyzer While using the analyzer user interface help can be accessed by selecting the Help...

Страница 23: ...OptiView Workgroup Analyzers to match the software version running on your PC You can obtain the latest version of software by visiting www flukenetworks com and downloading the file to the PC that yo...

Страница 24: ...ed Guide Step Two Connect to the Analyzer via the Management Port anj04f eps Figure 5 Direct Management Port Connection anj05f eps Figure 6 LAN Management Port Connection PC NIC Card Analyzer Manageme...

Страница 25: ...its update process of the firmware on the selected analyzer Note The Connection type has to show management port for the update firmware button to be enabled You cannot update the analyzer s firmware...

Страница 26: ...at the Front Page screen OptiView button and see if a valid IP has been configured Also see if the Auto Configure capability in the Setup TCP IP screen has been disabled If an IP address has been man...

Страница 27: ...ion Meets requirements of MIL PRF 28800F for Class 3 equipment Laser Class 1 Laser Product complies with 21 CFR 1040 10 1040 11 CFR J and EN60825 1 1994 A1 1997 A2 2002 Operating Temperature 10 C to 3...

Страница 28: ...EC Class C and D Cable Length Measurable cable lengths are from 3 feet 9 meter to 500 feet 152 meters Within this cable length the accuracy is 6 feet 2 meters Note Length accuracy is dependent upon th...

Страница 29: ...23 Workgroup Analyzer Safety and General Specifications...

Страница 30: ...iew Series III Workgroup Analyzer Getting Started Guide PN 3105444 February 2008 2008 Fluke Corporation All rights reserved Printed in USA All product names are trademarks of their respective companie...

Страница 31: ...Networks authorized service center within the warranty period To obtain warranty service contact your nearest Fluke Networks authorized service center to obtain return authorization information then...

Страница 32: ...notice this list of conditions and the following disclaimer in the documentation and or other materials provided with the distribution THIS SOFTWARE IS PROVIDED BY THE CRYPTIX FOUNDATION LIMITED AND C...

Страница 33: ......

Страница 34: ...OptiViewTM Workgroup Analyzer Default Configuration 8 Accessing the Analyzer through the Remote User Interface Software 8 Using the OptiViewTM Browser and User Interface Software 9 Refresh analyzer l...

Страница 35: ...ep Three Run the User Interface Software 18 Troubleshooting Your Analyzer 19 Before Calling Technical Support 19 Do you suspect the analyzer has locked up 19 Unexpected IP Discovery or Tools results 1...

Страница 36: ...Look for cracked or missing plastic Pay particular attention to the insulation surrounding the connectors Do not operate the product around explosive gas vapor or dust No serviceable parts Do not try...

Страница 37: ...inspection report ALWAYS NOTIFY THE CARRIER FIRST Please do not write the factory until you have notified the carrier since this will delay the claim If this precaution is not taken we cannot assist y...

Страница 38: ...wTM Series III Worgroup Analyzer supports 10 100 1000 Ethernet through the Network 10 100 1000 port RJ 45 jack along with a 1000BASE X fiber optic port that supports the following optional fiber adapt...

Страница 39: ...cations N A CD ROM OptiViewTM Resource CD Includes user interface software OptiView firmware MIB Browser and Getting Started Guide Multiple languages in PDF format N A Female to female DB 9 null modem...

Страница 40: ...nalyzer Bundle Includes OPV RPTR PRO and OPV PE PRO OPVS3 WGA GIG DSVS 19 Rack mount Kit Rack mount kit for holding one or two OptiViewTM Workgroup Analyzers OPV RMK Hard side transit case Hard shell...

Страница 41: ...ector Indicates that link has been established on the Management connection green Flashing green indicates activity is present Power PWR Indicates whether the analyzer is Off or On blue 10 100 1000 Fi...

Страница 42: ...ts The Management Port can be used to view traffic discovered on the Network 10 100 1000 or 1000BASE X fiber ports The Management Port is also used to flash new software into the analyzer Note Analyze...

Страница 43: ...on the Network Under Test Interface The network under test interface connects either through the Network 10 100 1000 or the 1000BASE X port It does not include the Management Port To set the IP addres...

Страница 44: ...t first configure the Remote Control IP address setting This is found in the Setup Remote screen The Remote Control IP address should match the IP address of the PC that you intend to run the OptiView...

Страница 45: ...yellow triangle indicates this This button is enabled only when selecting an OptiViewTM Workgroup Analyzer through the Management Port It does not apply to OptiViewTM Integrated analyzers Note Newer O...

Страница 46: ...BASE X fiber ports and not to the Management port Auto Reconfigure on Network Change is checked in the TCP IP setup screen and the analyzer patch cable is disconnected and reconnected to another jack...

Страница 47: ...or the password will appear to gain configuration access If the analyzer is not password protected configuration access is directly available The configuration port command line interface provides fou...

Страница 48: ...the IP address A B C D of the PC that will be running the remote user interface software The analyzer will send it s identification to that PC so that the OptiView Browser will display that analyzer...

Страница 49: ...thin the Management configuration mode ipaddr A B C D E F G H ipaddr autoconfig Statically assigns the IP address A B C D and subnet mask E F G H of the Network port Address and subnet mask are entere...

Страница 50: ...he analyzer Some of the topics of interest are exit Exits the Network configuration mode Exiting will discard any Network port configuration changes unless apply is entered show user command Displays...

Страница 51: ...nd Navigating the Help System ahq47s bmp Figure 4 The Help Screen The help system is an integral part of the analyzer While using the analyzer user interface help can be accessed by selecting the Help...

Страница 52: ...OptiView Workgroup Analyzers to match the software version running on your PC You can obtain the latest version of software by visiting www flukenetworks com and downloading the file to the PC that yo...

Страница 53: ...ed Guide Step Two Connect to the Analyzer via the Management Port anj04f eps Figure 5 Direct Management Port Connection anj05f eps Figure 6 LAN Management Port Connection PC NIC Card Analyzer Manageme...

Страница 54: ...its update process of the firmware on the selected analyzer Note The Connection type has to show management port for the update firmware button to be enabled You cannot update the analyzer s firmware...

Страница 55: ...at the Front Page screen OptiView button and see if a valid IP has been configured Also see if the Auto Configure capability in the Setup TCP IP screen has been disabled If an IP address has been man...

Страница 56: ...ion Meets requirements of MIL PRF 28800F for Class 3 equipment Laser Class 1 Laser Product complies with 21 CFR 1040 10 1040 11 CFR J and EN60825 1 1994 A1 1997 A2 2002 Operating Temperature 10 C to 3...

Страница 57: ...EC Class C and D Cable Length Measurable cable lengths are from 3 feet 9 meter to 500 feet 152 meters Within this cable length the accuracy is 6 feet 2 meters Note Length accuracy is dependent upon th...

Страница 58: ...org Powered by TCPDF www tcpdf org Powered by TCPDF www tcpdf org Powered by TCPDF www tcpdf org Powered by TCPDF www tcpdf org Powered by TCPDF www tcpdf org Powered by TCPDF www tcpdf org Powered by...

Отзывы: