10
OptiView
TM
Series III
Getting Started Guide
Refresh analyzer list
Re-displays the analyzer list with current active analyzers.
Launch user interface for selected analyzer
Launches the user interface software and connects to the selected analyzer. The selected analyzer is
highlighted in the OptiView Browser device list or the IP address is entered in the OptiView Browser IP
address field.
Launch Web browser for selected OptiView Integrated Network Analyzer
Enabled only for OptiView
TM
Integrated Network Analyzers and not for OptiView
TM
Workgroup Analyzers.
Launches the default Web browser on your PC and connects to the home page on the selected OptiView
TM
Integrated Network Analyzer. From the home page, you can access saved reports, packet capture files, and
data from OptiView Reporter, located on the hard drive of the OptiView
TM
Integrated Network Analyzer.
Update firmware for selected OptiView
TM
Workgroup Analyzer
Updates the firmware on the analyzer by downloading from the controlling PC. Perform analyzer firmware
updates when the local host software revision number is newer than the firmware revision number displayed
next to the selected analyzer (a yellow triangle indicates this). This button is enabled only when selecting an
OptiView
TM
Workgroup Analyzer through the Management Port. It does not apply to OptiView
TM
Integrated
analyzers.
Note
Newer OptiView Workgroup Analyzers run firmware version 5.2 or greater and have
new hardware to support them.
Older OptiView Workgroup Analyzers running firmware less than version 5.2 can only
be updated to firmware version 4.09. A yellow triangle will appear next to analyzers
less than 4.09 but greater than 3.51 indicating they can be updated to 4.09. OptiView
Workgroup Analyzers running 3.51 or less firmware can not be updated.
Installing the User Interface Software
The user interface software can be installed on Win98 SE, WinNT 4.0, Win2000, and WinXP operating
systems.
To install the user interface software from CD, insert the OptiView
TM
Resource CD into your PC’s CD drive.
Autorun will execute and load the CD user interface. If autorun is disabled on your PC, execute the file
launch.exe
located in the root directory on the CD. Follow the on-screen instructions to complete the
installation.
Once the installation is complete, you will be able to launch the OptiView Browser from your desktop, select
an analyzer from the OptiView Browser list, or enter the IP address of the analyzer, and gain access to
valuable network information through the user interface software.