![Fluke LinkIQ Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/fluke/linkiq/linkiq_user-manual_2309210028.webp)
LinkIQ
Users Manual
24
Test Limit Failure
shows a cable test that fails because of near end cross talk (NEXT).
Table 10. NEXT Failure
Item
Description
The Product detected the Remote ID, and the wire map passed.
The wire map passes because:
The wires are all connected correctly on both the near and far ends for a
straight through cable.
Allow Crossover
can be on or off to test a straight
through cable.
The continuity of the shield is not included as part of the test. (
Shield
>
).
The test fails because the test limit is set to verify the cable can support a
2.5BASE-T (2.5G) data rate throughput.
The cable can support 10BASE-T (10), 100BASE-TX (100), and
1000BASE-T (1G) data rate throughputs.
The cable cannot support 2.5BASE-T (2.5G) data rate throughput.
1
NEXT
1
3
2