General Specifications 

 i430-Flexi- 

 TF-II 

TF-II-48 

Transducer length 

61 cm (24 in) 

122 cm (48 in) 

Weight 

153 g 

200 g 

Transducer diameter 

7.5 mm (0.3 in) 

Minimum bending radius 

38 mm (1.5 in) 

Cable length from 
transducer to BNC  

2.5 m (98.4 in) 

Temperature, operating 

-20 °C to +70 °C (-4 °F to +158 °F) 
Temperature of conductor under test 
shall not exceed 80 °C (176 °F) 

Temperature, non-operating  -40°C to + 80 °C (-40 °F to +176 °F) 

Relative Humidity, operating  15 % to 85 %, noncondensing 

Altitude, operating 

2 000 m (6 500 ft); for use up to 4000 m 
derate to 300 V CAT IV, 600 V CAT III, 
1000 V CAT II. 

Altitude, storage 

12 km (40 000 ft) 

Ingress protection 

IP40 

LIMITED WARRANTY AND LIMITATION OF LIABILITY 

This Fluke product will be free from defects in material and workmanship for one 
year from the date of purchase. This warranty does not cover fuses, disposable 
batteries, or damage from accident, neglect, misuse, alteration, contamination, or 
abnormal conditions of operation or handling. Resellers are not authorized to extend 
any other warranty on Fluke’s behalf. To obtain service during the warranty period, 
contact your nearest Fluke authorized service center to obtain return authorization 
information, then send the product to that Service Center with a description of the 
problem. 

THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH 
AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. 
FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR 
CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR 
THEORY. Since some states or countries do not allow the exclusion or limitation of 
an implied warranty or of incidental or consequential damages, this limitation of 
liability may not apply to you.

 

Fluke Corporation 
P.O. Box 9090 
Everett, WA  98206-9090 
U.S.A. 

Fluke Europe B.V. 
P.O. Box 1186 
5602 BD Eindhoven 
The Netherlands 

11/99 

Содержание i430-Flexi-TF-II

Страница 1: ...heck the user documentation of your test tool for compatibility before you use this current sensor Available versions are i430 Flexi TF II 61 cm 24 inch i430 Flexi TFII 48 122 cm 48 inch Contacting Fluke To contact Fluke call one of the following telephone numbers Technical Support USA 1 800 44 FLUKE 1 800 443 5853 Calibration Repair USA 1 888 99 FLUKE 1 888 993 5853 Canada 1 800 36 FLUKE 1 800 36...

Страница 2: ...ductors are exposed Limit operation to the specified measurement category voltage or current ratings De energize the circuit or wear personal protective equipment in compliance with local requirements before you apply or remove the Product Do not touch voltages 30 V ac 42 V ac peak or 60 V dc Do not use the Product around explosive gas vapor or in damp or wet environments Do not use the Product if...

Страница 3: ...cuits connected directly to utilization points socket outlets and similar points of the low voltage MAINS installation Measurement Category III is applicable to test and measuring circuits connected to the distribution part of the building s low voltage MAINS installation Measurement Category IV is applicable to test and measuring circuits connected at the source of the building s low voltage MAIN...

Страница 4: ...low these instructions 1 Connect the BNC connector of the i430 Flexi TF II to the input on the Fluke 430 series Power Quality Analyzer 2 Wear protective equipment or de energize the circuit before you connect the flexible probe around the conductor See Figure 1 C B A 1 3 1 3 1 3 D hcf157 eps Figure 1 3 Re energize the circuit if not energized 4 Center the conductor perpendicularly inside the flexi...

Страница 5: ...y Remove the input signals before you clean the Product Have an approved technician repair the Product The flexible probe and its latching system require no special care For routine maintenance 1 Ensure that no foreign body obstructs the latching mechanism 2 Clean the Probe with a damp cloth and a mild detergent Do not use abrasives solvents or alcohol 3 Do not immerse the Probe in liquids If the ...

Страница 6: ...f reading at 10 to 100 of range Noise 1 mV rms at 10 Hz to 10 kHz Additional errors temperature coefficient over operating temperature range for 24 inch model 0 02 of reading C 0 011 F for 48 inch model 0 035 of reading C 0 02 F with position of conductor in the probe window see Figure 1 Zone A Zone B Zone C 0 5 to 30 A 0 5 of reading 1 0 of reading 2 0 of reading 1 count or 0 1 A whichever is gre...

Страница 7: ...er fuses disposable batteries or damage from accident neglect misuse alteration contamination or abnormal conditions of operation or handling Resellers are not authorized to extend any other warranty on Fluke s behalf To obtain service during the warranty period contact your nearest Fluke authorized service center to obtain return authorization information then send the product to that Service Cen...

Отзывы: